Download Print this page

Runxin 53602 User Manual

Multi-functional flow control valve for water treatment systems

Advertisement

Quick Links

Multi-functional Flow Control Valve for
Water Treatment Systems
53602(Old Model No.: F71B3)
53604(Old Model No.:F67C3)
53604S(Old Model No.:F67B3)
53606S(Old Model No.:F67B3-A)
53610(Old Model No.:N75A3)
53610B(Old Model No.:N75B3)
User Manual
Please read this manual in details before using the valve
and keep it properly in order to consult in the future.
0WRX.466.597

Advertisement

loading
Need help?

Need help?

Do you have a question about the 53602 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Runxin 53602

  • Page 1 Multi-functional Flow Control Valve for Water Treatment Systems 53602(Old Model No.: F71B3) 53604(Old Model No.:F67C3) 53604S(Old Model No.:F67B3) 53606S(Old Model No.:F67B3-A) 53610(Old Model No.:N75A3) 53610B(Old Model No.:N75B3) User Manual Please read this manual in details before using the valve and keep it properly in order to consult in the future.
  • Page 2 MODEL F71B3/F67C3/F67B3/F67B3-A/N75A3/N75B3 Before the valve put into use, please fill in the below content so as to help us to refer in the future. Filter System Configuration Tank Size: Dia. mm; Height Refilled Filter Materials Granularity of Filter Materials Control Valve Model ;...
  • Page 3 MODEL: F71B3/F67C3/F67B3/F67B3-A/N75A3/N75B3 Catalogue Notice ................... 1. Product Overview ..............1.1. Main Application & Applicability ........1.2. Product Characteristics ........... 1.3. Service Condition ............1.4. Product Structure and Technical Parameters ....1.5. Installation ..............2. Basic Setting & Usage ............. 2.1. The Function of PC Board ..........2.2.
  • Page 4 MODEL F71B3/F67C3/F67B3/F67B3-A/N75A3/N75B3 Notice  To ensure normal operation of the valve, please consult with professional installation or repairing personnel before use it.  If there are any of pipeline engineering and electric works, there must be finished by professional at the time of installation ...
  • Page 5: Product Overview

    MODEL F71B3/F67C3/F67B3/F67B3-A/N75A3/N75B3 suggested to install the strainer with M88×2 male thread. 1.Product Overview 1. 1. Main Application & Applicability Used for filtering water treatment systems Be suitable for Swimming pool filtering equipment Carbon filter or sand filter in RO pretreatment filtering system Iron and manganese removal system 1.2.
  • Page 6: Interlock Function

    MODEL F71B3/F67C3/F67B3/F67B3-A/N75A3/N75B3 No operations to buttons on the controller within 1 minute, button lock indicator lights on which represent buttons are locked. Before operation, press and hold the buttons for 5 seconds to unlock. This function can avoid incorrect operation. Rinsing frequency ...
  • Page 7 When the water turbidity exceeds the conditions, the impurity in the inlet water should be coagulated and precipitated firstly. 1.4. Product Structure and Technical Parameters F71B3 Appearance: Flow Rate A(mm) B(mm) H(mm) Transformer Model Output @0.3MPa F71B3(53602) 182.5 195.5 DC12V, 1.5A...
  • Page 8 MODEL F71B3/F67C3/F67B3/F67B3-A/N75A3/N75B3 F67B3 Appearance: F67C3 Appearance: Riser Pipe A(mm) B(mm) H(mm) Transformer Flow Rate m Model Size Output @0.3MPa F67B3 1.05’’OD (53604S) (26.7mm) F67B3-A 1’’D-GB DC12V, 1.5A (53606S) (32mm) F67C3 1.05’’OD 178.5 (53604) (26.7mm)...
  • Page 9 MODEL F71B3/F67C3/F67B3/F67B3-A/N75A3/N75B3 N75A3 Appearance: Flow Rate A(mm) B(mm) H(mm) Transformer Model Output @0.3MPa N75A3(53610) 346.5 230.5 DC24V, 1.5A 10.0 N75B3 (53610B) 216.5 312.5 Flow Meter Appearance:...
  • Page 10: Installation

    MODEL F71B3/F67C3/F67B3/F67B3-A/N75A3/N75B3 1.5. Installation A. Installation notice Before installation, read all those instructions completely. Then obtain all materials and tools needed for installation. The installation of product, pipes and circuits should be accomplished by professional to ensure the product can operate normally.
  • Page 11 MODEL F71B3/F67C3/F67B3/F67B3-A/N75A3/N75B3 tank, cut off the exceeding pipe out of tank top opening and make external rounding. b. Fill the filter materials to the tank, and the height is accordance with the design code. c. Install the top strainer to the valve. d.
  • Page 12 MODEL F71B3/F67C3/F67B3/F67B3-A/N75A3/N75B3 d. Inlet pipeline should be in parallel with outlet pipeline. Support inlet and outlet pipeline with fixed holder. Note: ●If making a soldered copper installation, do all sweat soldering before connecting pipes to the valve. Torch heat will damage plastic parts. ●When turning threaded pipe fitting onto plastic fitting, do not use excessive force to make threads misaligned or broken valve.
  • Page 13 MODEL F71B3/F67C3/F67B3/F67B3-A/N75A3/N75B3 2. Basic Setting & Usage 2.1. The Function of PC Board Time of day indictor Lights on, display the time of day. Button lock indicator Lights on, indicate the buttons are locked. At this moment, press  any single button will not work (No operation in one minute, will light on and lock the buttons.) ...
  • Page 14 MODEL F71B3/F67C3/F67B3/F67B3-A/N75A3/N75B3  In menu mode, press lights on, then enter program display mode to view all values.  In program display mode, press flashes, enter program set mode, press to adjust values.  Press after all parameters are set, and then the voice “Di” means all setting are successful and return program display mode.
  • Page 15 MODEL F71B3/F67C3/F67B3/F67B3-A/N75A3/N75B3 water drops to zero (0). Rinse will start untill at the rinsing time. Meter Immediate: Rinse immediately when the A-02 available volume of treated water drops to zero (0). Rinsing Time 02:00 02:00 00:00~23:59 Rinsing Time; “:” lights on Water Treatment 0~99:59 Capacity...
  • Page 16 MODEL F71B3/F67C3/F67B3/F67B3-A/N75A3/N75B3 Service Backwash Fast Rinse Illustration:  During the rinsing process, such as backwash and fast rinse status, the display screen will circularly shows: ① Current status (Such as 2-10:00 min. :sec. etc.), ②Time of day.  The display screen will only show “-00-” when the electrical motor is running.
  • Page 17 MODEL F71B3/F67C3/F67B3/F67B3-A/N75A3/N75B3 3. Applications 3.1. Filter Flow Chart 3.2. The Function and Connection of PC Board Open the front cover of control valve, you will see the main control board and connectors as below: A. F67/F71 control board (As below Figure 3-1A shows)
  • Page 18 MODEL F71B3/F67C3/F67B3/F67B3-A/N75A3/N75B3 N75 control board (As below Figure 3-1B shows) B. The wiring of liquid level controller connector, it refers to Figure 3-2: C. The wiring of remote handling connector, it refers to Figure 3-3:...
  • Page 19 MODEL F71B3/F67C3/F67B3/F67B3-A/N75A3/N75B3 D. When the signal output connector is connected with the water pump or solenoid valve, the working current is less than 5A. Its wiring refer to Figure 3-4. E. If the working current is less than 5A, the wiring of water pump refers to Figure 3-5 (Be suitable for iron and manganese removal device).
  • Page 20 MODEL F71B3/F67C3/F67B3/F67B3-A/N75A3/N75B3 Figure3-8 When connect the interlock wire with the main board socket, the wire color should be the same as the socket color. 3.3. System Configuration and Flow Rate Curve A. Product Configuration Product configuration with tank, filter materials volume Activated Carbon Filter Sand Filter Volume of...
  • Page 21 MODEL F71B3/F67C3/F67B3/F67B3-A/N75A3/N75B3 N75: 3.4. Parameter Enquiry and Setting 3.4.1. Parameter Enquiry When lights on, press and hold both for 5 seconds to unlock the button; then press lights on, enter to program display mode; press to view each value according to below process.
  • Page 22 MODEL F71B3/F67C3/F67B3/F67B3-A/N75A3/N75B3 3.4.2 Parameter Setting (Taking F67/F71 for example) In program display mode, press and enter into program set mode. Press to adjust the value. Items Process steps Symbol When the time of day “12:12” continuously flashes, it reminds to reset: 1.
  • Page 23 MODEL F71B3/F67C3/F67B3/F67B3-A/N75A3/N75B3 adjustment, press to turn back. 1. In the rinsing time program display mode, press and enter into program set mode, and 02 value flash; through to adjust Rinsing the hour value Time 2. Press again, both and “00” flash, through to adjust the minute value;...
  • Page 24 MODEL F71B3/F67C3/F67B3/F67B3-A/N75A3/N75B3 1. In the rinsing frequency display mode, it shows “F-00”; press and enter into program set Rinsing mode. and 01 flash; Frequency 2. Press to adjust the value; 3. Press and hear a sound “Di”, then finish adjustment, press to turn back.
  • Page 25: Trial Running

    MODEL F71B3/F67C3/F67B3/F67B3-A/N75A3/N75B3 1. In the opening time display mode, it shows 0-00:30, press and enter into program set Opening mode, and 00 value flash; Time of 2. Press to adjust the minute value; Drainage 3. Press , 30 flashes, press Ball Valve adjust the second value;...
  • Page 26 MODEL F71B3/F67C3/F67B3/F67B3-A/N75A3/N75B3 After the water sample analysis is qualified, press to end fast rinse. Then the control valve return to service status; lights on and start to running. Illustration:: In the process of rinsing, the program will be finished automatically in accordance with the setting time;...
  • Page 27: Troubleshooting

    MODEL F71B3/F67C3/F67B3/F67B3-A/N75A3/N75B3 3.6. Trouble-Shooting A. Control Valve Fault Problem Cause Correction A. Electrical service has A. Assure permanent electrical been interrupted. service (Check fuse, plug, switch 1. Filter fails to Rinse time and so on.). rinse. incorrect. B. Reset the time. C.
  • Page 28 MODEL F71B3/F67C3/F67B3/F67B3-A/N75A3/N75B3 A. Check and repair valve body or A. Internal valve leaks. 6. Drain flows replace it. B. Power off when in continuously. B. Turn off bypass valve and backwash or fast rinse. restart when power on. B. Controller Fault Problem Cause Correction...
  • Page 29: Assembly & Parts

    MODEL F71B3/F67C3/F67B3/F67B3-A/N75A3/N75B3 C. Control board damaged. 5. E3 or E4 Flash A. Control board damaged. A. Replace control board. 3.7. Assembly & Parts...
  • Page 30 MODEL F71B3/F67C3/F67B3/F67B3-A/N75A3/N75B3 F71B3(53602)Valve Body Assembly...
  • Page 31 MODEL F71B3/F67C3/F67B3/F67B3-A/N75A3/N75B3 F71B3(53602)Valve Body Components Item Quanti Item Quanti Description Part No. Description Part No. O-ring 73x5.3 8378143 Wire for Power 5513001 O-ring 25.8x2.65 8378078 Cable Clip 8126004 Flow Meter 5447020 Dust Cover 8005005 Screw, Cross Connector 8458206 8909004 ST2.2X6.5...
  • Page 32 MODEL F71B3/F67C3/F67B3/F67B3-A/N75A3/N75B3 F67B3(53604S)Valve Body Components...
  • Page 33 MODEL F71B3/F67C3/F67B3/F67B3-A/N75A3/N75B3 Item Quan Item Quant Description Part No. Description Part No. tity O-ring 8378078 Control Board 6382098 25.8x2.65 Screw, Cross O-ring 73x5.3 8378143 8909004 ST2.2X6.5 Flow Meter 5447018 Display Board 6386003 Sealing Ring 8371001 Front cover 8300001 Φ30*Φ23*3.3 Connector 8458205 Label 8865002...
  • Page 34 MODEL F71B3/F67C3/F67B3/F67B3-A/N75A3/N75B3 Screw, Cross 8909010 Spring 8282001 ST2.9X16 Dust Cover 8005001 Connecting Rod 8040001 Label 8869011 Clip Ring 8994001 Pointer 8441001 Check Ring 8950006 Screw, Cross 8909013 Washer 8952007 ST3.9X13 Symbol Label 8868004 Spring Washer 8953001 Label 8860001 Nut M6 8949001 Manual Wheel 8253001...
  • Page 35 MODEL F71B3/F67C3/F67B3/F67B3-A/N75A3/N75B3 N75A3(53610)Valve Body Assembly...
  • Page 36 MODEL F71B3/F67C3/F67B3/F67B3-A/N75A3/N75B3 N75A3(53610)Valve Body Components Item Item Description Part No. Quantity Description Part No. Quantity Screw, Cross 8909003 Dust Cover 8005010 ST3.9X19 Connector 8458018 Control Board 6382105 O-ring Wire for Locating 8378146 5511002 104.6X5.7 Board O-ring Screw, Cross 8378308 8909004 50.47X2.62 ST2.2X6.5 Valve Body...
  • Page 37 MODEL F71B3/F67C3/F67B3/F67B3-A/N75A3/N75B3 N75B3(53610B)Valve Body Assembly...
  • Page 38 MODEL F71B3/F67C3/F67B3/F67B3-A/N75A3/N75B3 N75B3(53610B)Valve Body Components Item Quan Item Quant Description Part No. Description Part No. tity Side-mounted 5458002 Dust Cover 8005023 Connector Screw, Cross Wire for Locating 8909003 5511002 ST3.9X19 Board Connector 8458018 Display Board 6381003 O-ring 8378146 Front Cover 8300025 104.6X5.7 O-ring...
  • Page 39 MODEL F71B3/F67C3/F67B3/F67B3-A/N75A3/N75B3 Fixed Base 8109004 Control Board 6382105 Screw, Cross 8909004 ST2.2X6.5 5458002 Side-mounted Connector Assembly 5458002 Side-mounted Connector Components Item Item Description Part No. Quantity Description Part No. Quantity Connection 8458037 Connector 8457017 O-ring 8378140 Steel Fork 8271003...
  • Page 40 MODEL F71B3/F67C3/F67B3/F67B3-A/N75A3/N75B3 5447020 Flow Meter Structure 5447020 Flow Meter Components: Item Item Description Part No. Quantity Description Part No. Quantity Shell 8002006 Impeller Supporter 5115023 O-ring Clip 8270005 8378064 21.89x2.62 Impeller 5115024 Connector 8458014 Supporter Impeller 5436013 5447018 Flow Meter Structure...
  • Page 41 MODEL F71B3/F67C3/F67B3/F67B3-A/N75A3/N75B3 5447018 Flow Meter Components Item Item Description Part No. Quantity Description Part No. Quantity Shell 8002001 5 Impeller Supporter 5115022 Clip 8270004 O-ring 28x2.65 8378081 Impeller 5115021 Animated Nut 8945001 Supporter Impeller 5436010 5447003 Flow Meter Structure 5447003 Flow Meter Components Item Item Description...
  • Page 42: Warranty Card

    This warranty card is the guarantee proof of Runxin brand multi-functional flow control valve. It is kept by client self. You could get the after-sales services from the supplier which is appointed by Runxin manufacturer. Please keep it properly. It couldn’t be retrieved if lost.
  • Page 43 Filter Material L Ground-water □ Tap Water □ Backwash Time Fast Rinse Time Service min. min. Problem Description WENZHOU RUNXIN MANUFACTURING MACHINE CO., LTD. ADD.: NO.169, RUNXIN ROAD, SHANFU TOWN, WENZHOU, ZHEJIANG, CHINA. TEL.:0086-577-88630038, 88576512, 85956057 FAX:0086-577-88633258 E-MAIL: sales@run-xin.com http://www.run-xin.com Rev.A.2111...