WaterLogic WL4FW FIREWALL Fault Finding page 17

Hide thumbs Also See for WL4FW FIREWALL:
Table of Contents

Advertisement

Steady Drip Out of Faucet
Possible Reason
Debris in Solenoid
Hot Water or Steam Coming out of both the Faucet and Vent Hole
Possible Reason
Improper tubing attachment
from the hot tank to faucet or
vice versa.
Hot Water Coming out of Faucet Vent Hole
Possible Reason
Improper tubing attachment
from the tank to faucet or vice
versa.
Hot Tank outlet hole is scaled
over.
Expansion chamber is not
sealed properly.
WL4FW Fault Finding
Inspect Solenoid for debris and clean out as needed.
Check that the tubing is connected from tank outlets to correct
faucet attachments. Connect tubing to outlets as needed.
Verify tubing is connected properly from tank outlets to correct
faucet attachments.
Inspect and Descale Tank as needed.
Replace the Hot Tank.
Solution
Solution
Solution
Page 17 – Revision: EU27-11-2017