Page 1
* Digital Lux Meter PRACTICAL MULTIMETER * Network Cable Tester * Power Factor Regulator * Earth Resistance Tester * Digital Panel Meters MODEL - KM 2807CSE * DC Power Supplies * High Voltage Detectors * Calibrators * Gas Detectors * Frequency Counter...
® ® TAKE MEASUREMENTS CAREFULLY AND YOU’LL SPARE TABLE OF CONTENTS YOUR METER AND YOURSELF, SOME PAIN. Nearly every electrical engineer has a hand held Multimeter. We sometimes take them for granted, until we damage them or “burn TITLE PAGE NO. them out”.
® ® 1) SAFETY The meter meets IEC/EN/BSEN/CSA_C22.2_No./UL standards of 61010-1 Ed. 3.1 and 61010-2-033 Ed. 2.0 to Measurement Categories CAT III 1000V and CAT IV 600V. The accompanied Terms in this manual test probe assembly meets IEC/EN/BSEN/CSA_C22.2_No./UL standards of 61010-031 Ed. 2.0 to the same meter ratings or WARNING identifies conditions and actions that could better.
® ® BRIEF INFORMATION ON MEASUREMENT CATEGORIES 4. SPECIFICATIONS : Measurement Category IV is applicable to test and measuring GENERAL SPECIFICATIONS : circuits connected at the source of the building’s low-voltage Display: 3-5/6 digits 6,000 counts MAINS installation. Examples are measurements on devices Update Rate: 5 per second nominal installed before the main fuse or circuit breaker in the building Operating Temperature: -10°C to 50°C...
® ® Electrical Specification: Power Supply: 1.5V AAA Size battery X 2 Accuracy is given as ± (% of reading digits + number of digits) or otherwise specified @ 23°C ± 5°C AC Voltage & Current Power Consumption (typical): 3.2mA accuracies are specified from 1 % to 100 % of range or otherwise iAPO Consumption (typical): 10µA specified.
Page 6
® ® VFD-ACV (with Low Pass Filter ) BeepLit™ Continuity Tester Continuity Threshold: Between 30Ω and 480Ω RANGE ACCURACY Continuity ON Response Time: <15ms 10Hz ~ 100Hz Audible Indication: Beep sound Visible Indication: LCD Backlight 1.0% + 3d 600.0V, 1000V Capacitance 10Hz ~ 100Hz 10.0% + 3d...
Page 7
® ® AC CURRENT LINE FREQUENCY RANGE ACCURACY BURDEN VOLTAGE FUNCTION RANGE SENSITIVITY 50Hz~500Hz (SINE RMS) 10Hz ~ 50kHz 600.0mA, 6000mA 0.1mV / mA 1.5% + 3d 10Hz ~ 50kHz 60.00mA, 600.0mA 3.0mV / mA 1.0% + 5d 10Hz ~ 1kHz 600V 6.000A, 10.00A 25mV / A...
® ® 3) PRODUCT DESCRIPTION ACV; Line-level Hz This user's manual uses only representative model(s) for Inputs are made via the terminals COM/V. Startup defaults to ACV illustrations. Please refer to detailed specifications for function Function. Press the SELECT button momentarily to select the availability to a particular model.
Page 9
® ® EF-Detection of Electric Field Non-Contact EF-Detection (NCV): ● An antenna is located near the top end center of the meter, which detects the ac electric Startup defaults to ACV Function. Press the SELECT button momentarily twice to select the EF-Detection function. The meter field surrounding energized conductors.
Page 10
® ® Note: Input sensitivity varies automatically with the function range Note: selected while activating the VFD-Hz function. 600V function 1) In ACmV function: range has the highest and the 1000V range has the lowest. When 1-1) ACmV startup defaults to the AC 600.0mV range. Auto- activated, the trigger voltage range will be displayed right ranging is not available.
Page 11
® ® connections (reverse biased) across the diode. The digital display Ω Resistance; BeepLitTM Continuity; & BeepLitTM Diode shows an over-range if the diode is good. Any other readings Inputs are made via the test lead terminals COM/Ω. Startup indicate the diode is resistive or shorted (defective). defaults to Ω...
Page 12
® ® DCA; ACA; ACA-Hz Inputs are made via the test lead terminals COM/A. Startup defaults to DCA. Press the SELECT button momentarily to select the subject functions in sequence. DCmA; ACmA; ACmA-Hz Inputs are made via the test lead terminals COM/ A mA. Startup (nF &...
Page 13
® ® Note: Discharge capacitor(s) before making capacitance LCD Backlight and Auto-Backlight-Off (ABO) measurements. Large-value capacitors should be discharged Press the SELECT button for 1 second or more to toggle the LCD through an appropriate resistance load. Using the Capacitance backlight.
® ® Battery replacement for models with battery access door: Loosen is released. This mode is designed mainly for production the 2 screws from the battery access door of the case bottom. Lift verification use. the battery access door and thus the battery compartment up. 5) MAINTENANCE Replace the batteries.
® TEST CERTIFICATE WARRANTY Each “KUSAM-MECO” product is warranted to be free from defects in TRMS ENHANCED material and workmanship under normal use & service. The warranty period is one year (12 months) and begins from the date of despatch of PRACTICAL MULTIMETER goods.
Need help?
Do you have a question about the KM 2807CSE and is the answer not in the manual?
Questions and answers