Chicago Pneumatic EPM15-15.5 Instruction Book

Chicago Pneumatic EPM15-15.5 Instruction Book

Oil-injected screw air compressor

Advertisement

Quick Links

Original Instruction
Oil-injected screw air compressor
Instruction book

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EPM15-15.5 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Chicago Pneumatic EPM15-15.5

  • Page 1 Original Instruction Oil-injected screw air compressor Instruction book...
  • Page 2 English...
  • Page 3 English Stationary Screw Rotary Compressor Units EPM15-15.5, EPM22-15.5 Instruction book Original instructions Copyright notice Any unauthorized use or copying of the contents or any part thereof is prohibited. This applies in particular to trademarks, model denominations, part numbers and drawings.
  • Page 4 English...
  • Page 5: Table Of Contents

    English CONTENTS PART A: INFORMATION FOR THE USER GENERAL CHARACTERISTICS INTENDED USE OPERATION GENERAL SAFETY STANDARDS DESCRIPTION OF DANGER SIGNALS DANGER ZONES SAFETY DEVICES POSITION OF SIGNS & DATA PLATES COMPRESSOR ROOM 10.0 TRANSPORT AND HANDLING 11.0 UNPACKING 12.0 INSTALLATION 13.0 DIMENSIONS AND TECHNICAL DATA 14.0...
  • Page 6 English INTRODUCTION In the event of breakdown or malfunction of the machine, switch it off and do not tamper with it. If repairs are needed, contact to a technical assistance centre approved by the manufacturer and insist on the use of original spare parts. Failure to comply with the above may endanger the safety of the machin Keep this manual with care for future consultation;...
  • Page 7: General Characteristics

    English 1.0 GENERAL CHARACTERISTICS The compressor units use single-stage screw rotary air compressors with oil injection. The central unit comprises:compressor; oil separator; oil cooler and output air cooler; fan; electric start; safety and regulation devices; instrument panel. The system is self-bearing and does not require bolts or other devices to anchor it to the floor. The unit is completely assembled in the factory;...
  • Page 8: General Safety Standards

    English 1 AF--AIR FILTER 9 OS--AIR-OIL SEPARATOR 2 IV--INLET VALUE 10 CA—AIR COOLER 3 E--ELEMENT 11 CO—OIL COOLER 4 CV--OIL CUT-OFF VALVE 12 EM-ELECTRIC MOTOR 5 AR--AIR-OIL PRESEPARATOR 13 FN--FAN 6 CL--CONTROLLER 14 VP—MIN PRESSURE VALVE 7 SV--SAFETY VALVE 8 OF--OIL FILTER 4.0 GENERAL SAFETY STANDARDS The appliance may be used only by specially trained and authorized personnel.
  • Page 9: Danger Zones

    English 6.0 DANGERS ZONES Risks present on the whole machine FIG 4...
  • Page 10: Safety Devices

    English 7.0 SAFETY DEVICES 1 Safety screws 2 Side panels, opened with a special key 3 Fixed protection device - cooling fan 4 Emergency push button 5 Safety valve 6 Oil filling cap (with safety breather) FIG 5...
  • Page 11: Position Of Signs & Data Plates

    English 8.0 POSITION OF SIGNS & DATA PLATES 8.1 POSITION OF THE DATA PLATE The plates fitted on the compressor unit are part of the machine; they have been applied for safety purposes and must not be removed or spoiled for any reason. 1 Compressed air outlet 2 Data plate FIG 6...
  • Page 12: Compressor Room

    English 9.0 COMPRESSOR ROOM 9.1 FLOOR The floor must be even and of industrial type for the total weight of the machine(Please refer to technical data).. Remember the total weight of the machine when positioning it. (See chapter 13.0) 9.2 VENTILATION When the machine is operating, the room temperature must not be higher than 40 °C or lower than 1 °C.
  • Page 13: Transport And Handling

    English 10.0 TRANSPORT AND HANDLING IT IS FORBIDDEN TO USE METAL CABLES FOR LIFTING ATTENTION: DO NOT STAND OR WALK PASS UNDER OVERHEAD WEIGHTS The machine must be transported as shown in the following figures. FORK LIFT TRUCK CARDBOARD PROTECTION AVOID DAMAGING THE BODYWORK FIG.
  • Page 14: Installation

    English 12.0 INSTALLATION 12.1 POSITIONING After unpacking the equipment and preparing the compressor room, put the machine into position, checking the following items: • ensure that there is sufficient space around the machine to allow maintenance (see Fig. 11). FIG. 10 Protect the power cable with a suitable channel.
  • Page 15 English 12.4 STARTING UP BEFORE CARRYING OUT ANY OPERATION ON THE MACHINE, ENSURE THAT THE ELECTRIC POWER SUPPLY HAS BEEN DISCONNECTED. 12.4.1 PREPARING FOR SETTING UP After checking everything as indicated in Chap. 12, follow the instructions in Fig. 12. 12.4.2 PRELIMINARI CHECKS - Check the oil level Ref.
  • Page 16: Machine Illustration

    English 9829 5626 42 EPM15-15 TMDD with 500L tank 9829 5626 43 EPM22-15 TMDD with 500L tank Installation Proposal 9829 2397 49 EPM7.5-45 9829 5621 06 E APM7.5-45 TMDD 14.0 MACHINE ILLUSTRATION 14.1 GENERAL LAY-OUT *It is forbidden to tamper the setting of the safety valve Compressor package Ref.
  • Page 17 English TMDD 14.2 Control panel instruction refer to saparated documents...
  • Page 18: Maintenance

    English 15.0 MAINTENANCE BEFORE CARRYING OUT ANY MAINTENANCE JOBS IT IS OBLIGATORY TO STOP THE MACHINE AND DISCONNECT IT FROM THE POWER MAINS. ◼ The maintenance jobs described in this chapter may be carried out by the user. ◼◼ The more complex maintenance jobs require professionally skilled personnel to carry out. 15.1 GENERAL INFORMATION Routine maintenance must be carried out according to the maintenance schedule displayed on the machine.
  • Page 19 English 15.3 MAINTENANCE SCHEDULE ◼ OPERATIONS THAT MAY BE CARRIED OUT BY THE USER ◼◼ OPERATIONS THAT REQUIRE SKILLED PERSONNEL These maintenance intervals are recommended for work environments that are not dusty and are well ventilated. For particularly dusty environments, double the frequency of intervals.For more information please contact manufacturer or nearest dealer Running time Plan...
  • Page 20 English - Turn off the cap of the oil tank Ref. 3 Fig. 16. - Close the panel. Note: If the oil has turned Creamy in Color contaminated with Condensate, Immediately contact dealer or Manufacturer, Do not operate the machine 15.5 CLEANING THE PRE-FILTER OF INLET AIR - Press the “STOP”...
  • Page 21: Periods Of Inactivity

    English THE OLD OIL MUST BE DISPOSED OF IN COMPLIANCE WITH THE REGULATIONS IN FORCE. NOTE ON LUBRICANTS When delivered the machine is filled with oil; In normal conditions of use, these lubricants have proved to be able to withstand use for as many as 4.000 hours.
  • Page 22: Trouble-Shooting And Emergency Remedies

    English 19.0 TROUBLE-SHOOTING AND EMERGENCY REMEDIES N.B. OPERATIONS MARKED ◼ ◼ MUST BE CARRIED OUT BY PROFESSIONALLY SKILLED PERSONNEL APPROVED BY THE MANUFACTURER. FAULT FOUND POSSIBLE CAUSES OBSERVATIONS 1) no power Check the power supply line, Chapter 12.2 2) Fuse burns Replace fuses ◼...