Salda AMBERAIR COMPACT CXP Mounting And Installation Instruction
Salda AMBERAIR COMPACT CXP Mounting And Installation Instruction

Salda AMBERAIR COMPACT CXP Mounting And Installation Instruction

Hide thumbs Also See for AMBERAIR COMPACT CXP:

Advertisement

Quick Links

AMBERAIR COMPACT CXP
EN
MOUNTING AND INSTALLATION INSTRUCTION

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AMBERAIR COMPACT CXP and is the answer not in the manual?

Questions and answers

Summary of Contents for Salda AMBERAIR COMPACT CXP

  • Page 1 AMBERAIR COMPACT CXP MOUNTING AND INSTALLATION INSTRUCTION...
  • Page 2: Table Of Contents

    8.7. WATER HEATER CIRCULATION PUMP AND VALVE ACTUATOR 8.8. PREHEATER AND COOLER 8.9. ELECTRICAL DIAGRAMS AND ABBREVIATION IN ELECTRICAL CIRCUIT DIAGRAMS 9. POSSIBLE FAULTS AND TROUBLESHOOTING 10. ECODESIGN DATA TABLE 11. DECLARATION OF CONFORMITY 12. WARRANTY 12.1. LIMITED WARRANTY COUPON | EN AMBERAIR COMPACT CXP v2021.2...
  • Page 3: Symbols And Marking

    Figure. 2.4. Technical label location and air duct indication (left side) side) Units tested and produced according to EC directives SALDA – associated member of the Eurovent association (Europe’s Industry Association for Indoor Climate (HVAC), Process Cooling, and Food Cold Chain Technologies) VDI 6022...
  • Page 4: Safety Instructions And Precautions

    The heating appliance can be starved of Salda Antifrost and use an external preheater for heat exchanger anti-frost protection (see Salda Antifrost function in the Remote Controller Operation Manual).
  • Page 5: Information About The Product

    Model box: CD50. Heating electric coil: Heating water coil: Right or left models: Fan (plastic/metal impellers): Cooling water coil: Control type: Not suitable for operation in pools, saunas and other similar premises. 4.2. DIMENSIONS AND WEIGHT AMBERAIR COMPACT CXP v2021.2 EN |...
  • Page 6: Technical Data

    [min 3370 3530 control input [VDC] 0-10 0-10 protection class IP54 IP54 Electrical heater [kW] [mm] 30/50 30/50 [mm] ePM1-70, 645x256x90 ePM10-55, 894x279x46 (class, dimensions LxWxH) [mm] ePM1-70, 645x256x90 ePM1-70, 894x279x46 (class, dimensions LxWxH) | EN AMBERAIR COMPACT CXP v2021.2...
  • Page 7: Operating Conditions

    STANDARD PACKAGE OF COMPONENTS AMBERAIR COMPACT 1 CX P 2 CX P 3 CX P 4 CX P Supply air temperature sensor TJ sion only) Hanging bracket Anti-vibration rubber Legs for ground version Legs for vertical version AMBERAIR COMPACT CXP v2021.2 EN |...
  • Page 8: Description Of Components

    4.6. DESCRIPTION OF COMPONENTS | EN AMBERAIR COMPACT CXP v2021.2...
  • Page 9: Installation

    The product is heavy. Exercise caution when transporting and installing. AMBERAIR COMAPCT [mm] [mm] [mm] 1 CX P 1707 1000 1900 2 CX P 2166 1200 2050 3 CX P 2398 1200 2164 4 CX P 2578 1200 2464 L1>L2 AMBERAIR COMPACT CXP v2021.2 EN |...
  • Page 10: Unpacking

    After unpacking AmberAir Compact 4 CX P, open the side covers and unscrew the supporting legs, which are used for trans- portation, from the fans. | EN AMBERAIR COMPACT CXP v2021.2...
  • Page 11: Piping And Instrumentation Diagram

    Water pre-heater circulation pump Water cooler circulation pump Water cooler valve motor Water pre-heater valve motor DX cooler valve motor Water heater valve motor Water heater temperature sensor Water preheater temperature sensor Water cooler temperature sensor AMBERAIR COMPACT CXP v2021.2 EN |...
  • Page 12: Mounting

    • AmberAir Compact 1 CX P is installed straight using a level. AmberAir Compact 2-4 CX P should be turned by 0.5-1 • • • AmberAir Compact 1 CX P is installed after alignment using a level. • Fig. 5.5.1.1 AmberAir Compact CX P mounting | EN AMBERAIR COMPACT CXP v2021.2...
  • Page 13: Unit Placing And Mounting Positioning Requirements

    5.6. UNIT PLACING AND MOUNTING POSITIONING REQUIREMENTS 1,5xL Figure 5.6.1. 5.7. CEILING-MOUNTING OF THE UNIT • “UNPACKING”. • • • • hole. • • 30 mm 50 mm 50 mm 30 mm AMBERAIR COMPACT CXP v2021.2 EN |...
  • Page 14: The Installation Of The Supporting Legs For The Floor-Mounted Version

    • • • max. 50 cm 30 mm 50 mm 50 mm 30 mm 5.7.2. DRAINAGE • • • • • • • • AmberAir Compact 1 CX P AmberAir Compact 2-4 CX P | EN AMBERAIR COMPACT CXP v2021.2...
  • Page 15: Connection Of The Air Duct

    Figure 5.9.1. Figure 5.9.2. Figure 5.9.3. supply supply supply • Install back control box cover. The manufacturer does not assume any liability for personal injuries and property damage due to nonconformance with the provided instructions. AMBERAIR COMPACT CXP v2021.2 EN |...
  • Page 16: Start-Up Recommendations

    • • all electrical equipment protection elements are properly connected (if they are additionally used), • • earthing and protection systems are properly installed, • condition of all seals and sealing surfaces is correct. | EN AMBERAIR COMPACT CXP v2021.2...
  • Page 17: Maintenance

    (approximately 2 min.). It necessary to assure, that the main switch cannot be turned on by the third parties. 1. The ordinary opening of doors using hinges; 2. The removal of doors using a rails system; AMBERAIR COMPACT CXP v2021.2 EN |...
  • Page 18 • The covers can be directly removed from the rails themselves or pushed to the other side of the product. 30 mm 50 mm 50 mm 30 mm • hexagonal key. • middle cover No 3. The door must be screwed on after maintenance. Recommended tightening is 2,7 N-m. | EN AMBERAIR COMPACT CXP v2021.2...
  • Page 19: Filters Maintenance

    FANS MAINTENANCE Before starting maintenance or repair work, make sure that the unit is disconnected from the electrical network and/or that • • The fan should be inspected and cleaned at least once per year. AMBERAIR COMPACT CXP v2021.2 EN |...
  • Page 20: Heat Exchanger Maintenance

    • Proceed to maintenance and repair after any rotation in the fan stopped. • Clean the heat exchanger once a year. • • • • The heat exchangers are removed either from the top or from the bottom. | EN AMBERAIR COMPACT CXP v2021.2...
  • Page 21: Electric, Water Heater Maintenance

    • • • Electrical heater does not require additional servicing. If necessary, electric heater can be removed. • • Open the doors of the product. • Disconnect the electrical heater from the harness. • AMBERAIR COMPACT CXP v2021.2 EN |...
  • Page 22: Control Board Maintenance

    • Remove the side seals from the heater pipes. • Figure 6.7.2. Water heater maintenance 6.8. CONTROL BOARD MAINTENANCE • • • • Remove control board. • and connector to corresponding connection terminal and connector. | EN AMBERAIR COMPACT CXP v2021.2...
  • Page 23: Control

    SALDA AIR mobile application SA-Control BMS over Modbus TCP/IP BMS over BACnet TCP/IP 7.2. DEVICE FUNCTIONS application and SALDA AIR mobile application. For unit control instructions, refer to the operation manual of the existing control device. AMBERAIR COMPACT CXP v2021.2 EN |...
  • Page 24: Connection Of Accessories

    More information can be found in the MCB_miniMCB Technical Manual. 8.2. EXTERNAL CO /RH SENSORS AmberAir Compact CXP units have one connection for external CO /RH (input 0-10 VDC) sensor. detection. Supply air RH is measured inside the supply air duct.
  • Page 25: Connection Of Remote Control Panel Or Modbus

    M2, M3 - Open/Close or Spring-return damper actuators. Upon activation of DO5 the dampers shall open. Upon activation of DO6 the dampers 8.6. CONNECTION OF REMOTE CONTROL PANEL OR MODBUS X18 connector is for Remote controller. X19 connector is for BMS. Switch Position Purpuse 8.7. WATER HEATER CIRCULATION PUMP AND VALVE ACTUATOR Wiring diagram AMBERAIR COMPACT CXP v2021.2 EN |...
  • Page 26: Preheater And Cooler

    Fireplace protection Transmitter2 Exhaust air CO sensor START Operation indicator START Warning indicator EX1 V1.0 EX1 V1.0 EX2 V1.0 01-7-4 01-3-4 EKS NIS ... -3f -PE1 01-3-4 01-3-4 Jumper* Jumper* Fig. 8.9.1 Electrical external pre-heater | EN AMBERAIR COMPACT CXP v2021.2...
  • Page 27 EX2 V1.0 0-10 VDC 24VDC -M16 Fig. 8.9.2 External water pre-heater - N2 - N2 - N2 EX1 V1.0 EX1 V1.0 EX1 V1.0 EX2 V1.0 0-10 VDC 24VDC -M14 Fig. 8.9.3 External water cooler AMBERAIR COMPACT CXP v2021.2 EN |...
  • Page 28 - N2 - N2 EX1 V1.0 EX1 V1.0 EX2 V1.0 EX2 V1.0 Jumper* 0-10 VDC 24VDC Fig. 8.9.4 External DX cooler Fig. 8.9.5 Fire protection connection | EN AMBERAIR COMPACT CXP v2021.2...
  • Page 29 Fig. 8.9.6 Motorised air dampers EX1 V1.0 EX1 V1.0 -Transmitter2 Fig. 8.9.7 CO or RH sensors AMBERAIR COMPACT CXP v2021.2 EN |...
  • Page 30 MCB V1.0 EX1 V1.0 EX1 V1.0 EX1 V1.0 -START -STOP -FPP Jumper* Jumper* 24VDC 24VDC max. 50mA max. 50mA 1.2W 1.2W Fig. 8.9.8 *The jumpers are installed by the manufacturer. | EN AMBERAIR COMPACT CXP v2021.2...
  • Page 31: Possible Faults And Troubleshooting

    (if installed) Manual safety device is activated MUST be contacted to identify and eliminate the failure . Filter replacement needed on the remote control panel broken, or its pressure is set improperly. AMBERAIR COMPACT CXP v2021.2 EN |...
  • Page 32: Ecodesign Data Table

    10. ECODESIGN DATA TABLE More details of the unit and each unit's component can be found on the "VentMaster" selection app. | EN AMBERAIR COMPACT CXP v2021.2...
  • Page 33: Declaration Of Conformity

    EMC Directive 2014/30/EU Low Voltage Directive 2014/35/EU Ecodesign Directive 2009/125/EC RoHS 2 Directive 2011/65/EU Ecodesign requirements for ventilation units Nr. 1253/2014 commercial and light-industrial environments. Quality: ISO 9001:2015. Date 2022-01-03 Giedrius Taujenis Product manager AMBERAIR COMPACT CXP v2021.2 EN |...
  • Page 34: Warranty

    The Limited Warranty Coupon shall be valid provided that the seller’s stamps and records are clear. It is not allowed to change, delete, or rewrite The manufacturer reserves the right to refuse provision of free warranty servicing in cases when the warranty conditions listed below are disregarded. | EN AMBERAIR COMPACT CXP v2021.2...
  • Page 35 AMBERAIR COMPACT CXP v2021.2...
  • Page 36 Look at the product label. ** - At least. NOTE. The customer shall be required to complete the Product Maintenance Table. MANUALS IN OTHER LANGUAGES https://select.salda.lt/file/ aacompactcxpde MAN000348 Ragainės g. 100 +370 41 540 415 Šiauliai LT-78109, LITHUANIA office@salda.lt...

Table of Contents