Blackened Glass
• The wood is too damp. Only use wood that has been stored for at least 12 months
under cover and ideally with a moisture content less than 20%.
• Insufficient intake of air from the air control. Open the air control further.
• Insufficient ventilation. The stove is being run at too low a temperature.
Smoke in the room when refuelling
• Poor chimney performance. Consult chimney sweep or installation engineer.
• Check the position of any fitted flue damper to make sure it is in the open position.
• Never open the door when there are high flames on the wood.
Uncontrollable Combustion
• Damaged door seal. Fit new seal.
• If there is excessive chimney draft, fit a draft stabiliser in the flue pipe. Consult a
chimney sweep or the installation engineer.