Vivotek 4X-SD8111 User Manual page 142

H.264 12x zoom day&night 3d noise reduction
Hide thumbs Also See for 4X-SD8111:
Table of Contents

Advertisement

VIVOTEK
Senddata (capability.nuart>0)
Note: This request requires Viewer privileges.
Method: GET/POST
Syntax:
http://<servername>/cgi-bin/viewer/senddata.cgi?
[com=<value>][&data=<value>][&flush=<value>] [&wait=<value>] [&read=<value>]
PARAMETER
VALUE
com
1 ~ <max. com port number> The target COM/RS485 port number.
data
<hex decimal data>[,<hex
decimal data>]
flush
yes,no
wait
1 ~ 65535
read
1 ~ 128
Return:
HTTP/1.0 200 OK\r\n
Content-Type: text/plain\r\n
Content-Length: <system information length>\r\n
\r\n
<hex decimal data>\r\n
Where hexadecimal data is digits from 0 ~ 9, A ~ F.
Storage managements (capability.storage.dbenabled=1)
Note: This request requires
Method: GET and POST
Syntax:
http://<servername>/cgi-bin/admin/lsctrl.cgi?cmd=<cmd_type>[&<parameter>=<value>...]
The commands usage and their input arguments are as follows.
142 - User's Manual
DESCRIPTION
The <hex decimal data> is a series of digits from 0 ~ 9, A ~ F.
Each comma separates the commands by 200 milliseconds.
yes: Receive data buffer of the COM port will be cleared before
read.
no: Do not clear the receive data buffer.
Wait time in milliseconds before read data.
The data length in bytes to read. The read data will be in the
return page.
administrator
privileges.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sd8111Sd8121

Table of Contents