3.2 Status LED light errors
The eHome Link is capable of detecting the following operating errors:
- Disabled Socket-outlet
- D state Error
- E state Error
- Proximity Error
- Negative PWM voltage Error
- RCD Error
- Maximum selected output current Error
- Welded Contact Error
- Temperature Error
Whatever the error case is, the Charge Point will stop charging and technical assistance
will be required, except from the temperature error. In this last case, the Charge Point
starts charging when the operating temperature is reached again.
In the following sections it will be explained how the eHome Link indicates the above
mentioned errors and the actions taken by the Charge Point.
1 — D I S A B L E D S O C K E T - O U T L E T
This means that the socket-outlet is disabled, so the charging procedure cannot start.
If this is the case, the status LED light would turn into red.
Fix
2 — D S T A T E E R R O R
In some old EVs, this state means that there are some gases coming out from the
batteries. So, an external ventilation in the car park might be required. If it were the
case, the status LED light would turn into red and keep blinking permanently.
1
Blink Sequence
09

Advertisement