Delta Ultron DPS Gen2 Series User Manual

Delta Ultron DPS Gen2 Series User Manual

Three-phase, 380/400/415 vac 800/1000/1200kva
Table of Contents

Advertisement

Quick Links

The power behind competitiveness
Delta UPS Ultron Family
DPS Gen2 Series, Three-Phase, 380/ 400/ 415 Vac
800/ 1000/ 1200 kVA
User Manual
www.deltaww.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Ultron DPS Gen2 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Delta Ultron DPS Gen2 Series

  • Page 1 The power behind competitiveness Delta UPS Ultron Family DPS Gen2 Series, Three-Phase, 380/ 400/ 415 Vac 800/ 1000/ 1200 kVA User Manual www.deltaww.com...
  • Page 2: Save This Manual

    Manual at any time without obligation to notify any person of such revision or changes. Delta will make all possible efforts to secure the accuracy and the integrity of this Manual.
  • Page 3: Table Of Contents

    Table of Contents Table of Contents SAVE THIS MANUAL ......................2 Table of Contents ........................ 3 Chapter 1 : Important Safety Instructions ................7 Installation Warnings ................. 7 Connection Warnings ................ 7 Usage Warnings ................9 Storage Warnings ................11 Standard Compliance ..............
  • Page 4 Parallel Units Wiring ............... 76 External Battery Cabinet Connection Warnings ......78 Installation of Rodent Shields ............87 5.6.1 Installation of 800kVA UPS’s Rodent Shields ......87 5.6.2 Installation of 1000/1200kVA UPS’s Rodent Shields ....89 Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 5 Table of Contents Chapter 6 : UPS Operation ....................93 Pre Start-up & Pre Turn-off Warnings .......... 93 Start-up Procedures ..............94 6.2.1 On-Line Mode Start-up Procedures ..........94 6.2.2 Battery Mode Start-up Procedures ..........95 6.2.3 Bypass Mode Start-up Procedures ..........96 6.2.4 Manual Bypass Mode Start-up Procedures .........
  • Page 6 BMS Function on the LCD Screen ..........140 MFC Function on the LCD Screen ..........142 Chapter 9 : Maintenance ....................144 Appendix 1 : Technical Specifications ................145 Appendix 2 : Warranty ...................... 148 Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 7: Chapter 1 : Important Safety Instructions

    5.2 Installation Environment maintenance. Please refer to • Only authorized Delta engineers or service personnel can perform installation and maintenance. If you want to install the UPS by yourself, please install it under the supervision of authorized Delta engineers or service personnel.
  • Page 8 1. For single input, you must install (1) a protective device between the main AC source and the UPS and (2) a protective device between the connected critical loads and the UPS. Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 9: Usage Warnings

    Chapter 1 : Important Safety Instructions 2. For dual input, you must install (1) a protective device between the main AC source and the UPS, (2) a protective device between the bypass source and the UPS and (3) a protective device between the connected critical loads and the UPS.
  • Page 10 • Do not open or remove the covers or panels of the UPS to avoid high-voltage electric shock. Only authorized Delta engineers or service personnel can do so for installation or maintenance. If you want to open or remove the covers or panels, do it only under the supervision of authorized Delta engineers or service personnel.
  • Page 11: Storage Warnings

    Please note that the battery grounds mean any battery pole (+/ -) connecting to the ground. • You must contact Delta customer service if any of the following events occurs: 1. Any liquid is poured or spilled on the UPS.
  • Page 12: Chapter 2 : Introduction

    Please check if any items are missing according to the following package lists. If the UPS needs to be returned, carefully repack the UPS and all of the accessories using the original packing materials that came with the unit. 800kVA UPS Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 13 Chapter 2 : Introduction Item Q’ty 1 PC ❶ User Manual 1 PC ❷ Test Report 1 PC ❸ Snap Bushing 2 PCS ❹ Key (placed inside the UPS cabinet) 2 PCS ❺ USB Cable 1 PC ❻ Parallel Cable 1 PC ❼...
  • Page 14 Item Q’ty I/O Cabinet 1 PC ❶ Connection Bus Bar (three types A, B and C) 12 PCS ❷ M10 Screw 80 PCS ❸ 1000/ 1200kVA UPS’s Power Cabinet & System Cabinet Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 15 Chapter 2 : Introduction Item Q’ty Power Cabinet & System Cabinet 1 SET ❶ User Manual 1 PC ❷ Test Report 1 PC ❸ Snap Bushing 2 PCS ❹ Key (placed inside the I/O cabinet) 2 PCS ❺ USB Cable 1 PC ❻...
  • Page 16: Functions & Features

    • Connects to four external battery cabinets at maximum to extend the backup time. • Provides setting options such as battery test (schedulable) and battery replacement alarm. Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 17: Exterior & Dimensions

    Chapter 2 : Introduction • Battery temperature monitoring and compensation. • Optional battery management system (BMS) allows measurement of every battery’s voltage. • Smart battery charger design allows auto-charging or manual charging to shorten the charging time. • Provides diversified communication interfaces and a SMART slot. Please refer to 4.
  • Page 18 I/O cabinet together. Power Cabinet System Cabinet Cabinet Vents 2000 mm (78.74") 2450 mm (96.45") 900 mm (35.43") Figure 2-2: 1000/ 1200kVA UPS_ Exterior & Dimensions Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 19: Front View_ 800Kva

    Chapter 2 : Introduction Front View_ 800kVA Power System Cabinet Cabinet Cabinet 10” Color Touch Tri-color LED Panel EMERGENCY POWER Indicator OFF (EPO) Button Keyhole Door Handle Stands Figure 2-3: 800kVA UPS_ Front View Power System Cabinet Cabinet Cabinet Unscrew the Four Screws Keyhole Pull Up...
  • Page 20: Front View_ 1000/ 1200Kva

    System Cabinet Tri-color LED Indicator 10” Color Touch Panel EMERGENCY POWER OFF (EPO) Button Keyholes Door Handle Stands Figure 2-6: 1000/ 1200kVA UPS_ Front View of the Power Cabinet & System Cabinet Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 21 Chapter 2 : Introduction I/O Cabinet Unscrew the Four Screws Figure 2-7: 1000/ 1200kVA UPS_ How to Open the Front Door of the I/O Cabinet Power Cabinet System Cabinet Pull Up Keyholes Figure 2-8: 1000/ 1200kVA UPS_ How to Open the Front Doors of the Power Cabinet &...
  • Page 22: Internal View_ 800Kva

    & cover removal, maintenance and operation. If you want to execute any action mentioned above by yourself, the action must be under the supervision of authorized Delta engineers or service personnel. I/O Cabinet (Figure 2-9: 800kVA UPS_ Internal View of the I/O Cabinet)
  • Page 23 Chapter 2 : Introduction UPS Output Terminals (L1/ L2/ L3) Battery Terminals (+/ -) N Terminals for UPS Output, Bypass Input and AC Input Bypass Input Terminals (L1/ L2/ L3) PE ( ) & GND ( Terminals AC Input Terminals (L1/ L2/ L3) Figure 2-10: 800kVA UPS_ Wiring Terminals inside the I/O Cabinet...
  • Page 24 5. The power outlet (220/ 230/ 240 Vac, 3.15A) is without galvanic isolation. NOTE: Only authorized Delta engineers or service personnel can use the power outlet. If you want to use the power outlet by yourself, it must be under the supervision of authorized Delta engineers or service personnel.
  • Page 25: Internal View_ 1000/ 1200 Kva

    & cover removal, maintenance and operation. If you want to execute any action mentioned above by yourself, the action must be under the supervision of authorized Delta engineers or service personnel. I/O Cabinet Figure 2-13: 1000/ 1200kVA UPS_ Internal View of the I/O Cabinet...
  • Page 26 PE ( ) & GND ( Terminals N Terminals for UPS Output, Bypass Input and AC Input Battery Terminals (+/ -) Figure 2-14: 1000/ 1200kVA UPS_ Wiring Terminals inside the I/O Cabinet Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 27 3. The power outlet (220/ 230/ 240 Vac, 3.15A) is without galvanic isolation. NOTE: Only authorized Delta engineers or service personnel can use the power outlet. If you want to use the power outlet by yourself, it must be under the...
  • Page 28: Tri-Color Led Indicator & Buzzer

    Please see the figure above. Tri-color LED Indicator & Buzzer Tri-color LED Indicator Figure 2-17: Tri-color LED Indicator Location NOTE: 7. LCD Display For information about the 10” color touch panel, please refer to & Settings Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 29 Chapter 2 : Introduction The buzzer is located at the rear of the system cabinet’s front door. Please refer to the figures below. System Cabinet Buzzer Figure 2-18: 800kVA UPS_ Buzzer Location System Cabinet Buzzer Figure 2-19: 1000/ 1200kVA UPS_ Buzzer Location...
  • Page 30 Warning Level Buzzer Frequency It sounds 0.5 seconds Minor every 3 seconds. It sounds 0.5 seconds Medium every second. • It indicates a major warning message. Warning Level Buzzer Frequency Major Long beep. Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 31: Chapter 3 : Operation Modes

    The UPS runs in six basic operation modes, which are On-Line mode, Battery mode, Bypass mode, Manual Bypass mode, ECO mode and Frequency Conversion mode. Please note that Clean mode is optional. Only trained Delta engineers can enable this function. If needed, please contact Delta customer service.
  • Page 32: On-Line Mode

    On-Line mode, the UPS’s tri-color LED illuminates green and the text ‘On-Line’ appears in the upper right corner of the LCD screen. . External Maintenance Bypass Cabinet Maintenance Bypass Static Switch BYPASS Inverter Rectifier LOAD MAIN Batteries Figure 3-1: On-Line Mode Diagram Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 33: Battery Mode

    Chapter 3 : Operation Modes Battery Mode The UPS transfers to Battery mode automatically if the main AC source is abnormal, for example, when unstable voltage or a power outage occurs. In Battery mode, the batteries provide DC power and the UPS converts it into AC power and supplies it to the connected critical loads via the external maintenance bypass cabinet’s Output Breaker or Switch (Q4).
  • Page 34: Bypass Mode

    ‘Bypass’ appears in the upper right corner of the LCD screen. External Maintenance Bypass Cabinet Maintenance Bypass Static Switch BYPASS Inverter Rectifier LOAD MAIN Batteries Figure 3-3: Bypass Mode Diagram Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 35: Manual Bypass Mode

    Chapter 3 : Operation Modes Manual Bypass Mode When the UPS runs in Manual Bypass mode, the current only flows through the maintenance bypass so that the maintenance personnel can maintain the circuit inside the UPS. However, DO NOT touch any external maintenance bypass cabinet’s terminal and bus bar which may carry high-voltage electricity.
  • Page 36: Eco Mode

    During ECO mode, the UPS’s tri-color LED illuminates green and the text ‘ECO’ appears in the upper right corner of the LCD screen. External Maintenance Bypass Cabinet Maintenance Bypass Static Switch BYPASS Inverter Rectifier LOAD MAIN Batteries Figure 3-5: ECO Mode Diagram Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 37: Frequency Conversion Mode

    Chapter 3 : Operation Modes Frequency Conversion Mode NOTE: Frequency Conversion mode is only applicable to single UPS, but not to parallel UPSs. After the UPS is manually set as Frequency Conversion mode via the LCD, the inverter will automatically select 50Hz or 60Hz as the fixed output frequency. After the output frequency is determined, the system will automatically disable the bypass function.
  • Page 38: Clean Mode

    Clean Mode NOTE: Clean mode is optional. Only trained Delta engineers can enable this function. If needed, please contact Delta customer service. After the UPS is manually set as Clean mode via the LCD, the system will automatically detect the output status to let the inverter provide active filter function to compensate harmonics, correct power factor and reduce bypass reactive current to improve overall power quality.
  • Page 39: Chapter 4 : Communication Interfaces

    Chapter 4 : Communication Interfaces Chapter 4 : Communication Interfaces The communication interfaces are hot-swappable and located at two different places. One is on the front of the system cabinet with its front door open and the other is at Figure 2-11 Figure 2-15 the rear of the touch panel.
  • Page 40: Display Port

    Connect the REPO dry contacts to a user-supplied switch and you can remotely shut down the UPS when an emergency occurs. The REPO dry contacts provide normally open (NO) and normally closed (NC) these two options for use. Figure 4-2: REPO Dry Contacts & Schematic Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 41 Chapter 4 : Communication Interfaces NOTE: To enable the normally closed (NC) function, please take out the dry contact card and remove its Jump CNR3 before you turn on the UPS. Screw x 2 Dry Contact Card Figure 4-3: Location of the Dry Contact Card Jump CNR3 Dry Contact Card Figure 4-4: Location of the Jump CNR3...
  • Page 42: External Battery Temperature Detection

    NOTE: Only trained Delta engineers can enable the function. Please contact Delta customer service for implementation. Figure 4-6: External Switch/ Breaker Status Dry Contacts & Schematic...
  • Page 43: Output Dry Contacts

    Chapter 4 : Communication Interfaces 4.1.5 Output Dry Contacts There are six sets of programmable output dry contacts (P1 ~ P6). Please use the touch panel to set each dry contact as normally open (NO) or normally closed (NC). Each dry contact can be assigned a specific event. Six out of twenty-one events can 7.6.6 be assigned according to your applications.
  • Page 44 Battery Over Temperature too high. Output Voltage Abnormal The output voltage is abnormal. Battery Need Replacement The battery replacement date is due. The bypass static switch temperature is too Bypass Over Temperature high. Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 45: Input Dry Contacts

    Chapter 4 : Communication Interfaces Event Description The bypass static switch has an open/ short Bypass Static Switch Fault issue. UPS Over Temperature The UPS temperature is too high. When the EPO button is pressed, the UPS will send a signal to the connected external Battery Breaker Shunt Trip shunt trip device to cut off the battery power.
  • Page 46 The battery fuse is blown. Charger Off* Turn off the charger. NOTE: If you use non-Delta lithium-ion batteries, you must set up Charger Off this 7.6.6 Dry Contact Setting item. Please refer to . For settings relevant to the 7.6.4 Battery & Charging...
  • Page 47: Parallel Communication Cards

    WARNING:  One parallel cable is provided in each UPS’s accessory package. Using non- Delta parallel cables to parallel the UPSs may cause failure, malfunctions and accidents. Parallel Ports Figure 4-10: Location of the Parallel Ports...
  • Page 48: Smart Slot

    Please refer to Interfaces 2. If you use the Delta lithium-ion batteries (please refer to the Delta P/N shown below), you must install the optional multifunctional communication card (MFC) into the SMART slot to monitor the battery status. For settings and information 7.6.4 Battery &...
  • Page 49: Usb Port & Rs-232 Port

    Chapter 4 : Communication Interfaces NOTE: One Ethernet cable is provided in each package of the optional multi- functional communication card (MFC). SMART Slot Figure 4-11: Location of the SMART Slot 4.1.10 USB Port & RS-232 Port The USB port & RS-232 port are available for authorized service personnel. USB Port &...
  • Page 50: Battery Start Buttons

    Start-up Procedures Battery Start Button Battery Start Button Figure 4-14: Location of the Battery Start Buttons Communication Interfaces (II): at the Rear of the Touch Panel Figure 4-15: 800kVA UPS_ Communication Interfaces (II) Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 51 Delta EnviroProbe 1000 (optional). DISPLAY Before shipment, the DISPLAY port has been connected. ❹ Connect the port to the Delta battery management system (optional). The BMS function is only applicable to ❺ lead-acid batteries. 1. Provision of Modbus RTU communication service.
  • Page 52: Cable Routing For The Communication Interfaces

    1000/ 1200kVA UPS’s drawing is taken (Top Cable Entry) as an example. Route the Cables through the Snap Bushings Figure 4-17: 800/ 1000/ 1200kVA UPS_ Top Cable Entry for the Communication Interfaces Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 53 Chapter 4 : Communication Interfaces Bottom Cable Entry for 800kVA UPS Open the 800kVA UPS’s front doors. Follow the figures below to fix the provided cable ties in the holes and use the cable ties to fix the cables connected to the communication interfaces (❶).
  • Page 54 Please follow local and national electrical codes to select cable sizes and install proper conduits and bushings for cable protection. 5.3 UPS Installation 2. Only when is completed can you perform wiring. Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 55: Chapter 5 : Installation And Wiring

    Delta engineers or service personnel. If you use a forklift or other equipment to move the UPS, please make sure its load bearing is sufficient. Please...
  • Page 56 Dust filters have been installed on the inner side of the UPS’s front doors before shipment. Air Outlet at the Rear Air Inlet at the Front Figure 5-1: 800kVA UPS_ Air Inlet & Outlet Direction Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 57 Chapter 5 : Installation and Wiring Air Outlet at the Rear Air Inlet at the Front Figure 5-2: 1000/ 1200kVA UPS_ Air Inlet & Outlet Direction WARNING:  1. Do not use air conditioners or similar equipment to blow into the rear of the UPS.
  • Page 58: Ups Installation

    Please firmly fix the stands which are at the bottom of the UPS on the ground to avoid UPS movement. Each stand requires a M12 expansion screw (provided by qualified service personnel). Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 59 Chapter 5 : Installation and Wiring Figure 5-4: 800kVA UPS_ Cabinet Floor Fixing Points Figure 5-5: 1000/ 1200kVA UPS_ Cabinet Floor Fixing Points...
  • Page 60 (❸) from the system cabinet’s internal panel, and use the provided eighty M10 screws and sixteen M12 screws to install the provided twelve connection bus bars (❹) as shown in the figure below. Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 61 Chapter 5 : Installation and Wiring (Power (System (I/O Cabinet) Cabinet) Cabinet) (I/O Cabinet) Open the Open the Install the Provided Front Door Front Door Connection Bus Bars Remove the Eight Screws (System Cabinet’s Internal View) Figure 5-8: 1000/ 1200kVA UPS_ Install the Provided Connection Bus Bars...
  • Page 62 UPS. After that, reinstall the removed panels and close the front doors. Step 7 5.6 Installation of Rodent After the steps above have been completed, please refer to Shields to install the rodent shields. Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 63: Wiring

    & cover removal, maintenance and operation. If you want to execute any action mentioned above by yourself, the action must be under the supervision of authorized Delta engineers or service personnel. The UPS must be connected with an external maintenance bypass cabinet (user-supplied, handled and configured by Delta service personnel).
  • Page 64 External Maintenance Bypass Cabinet’s Manual Bypass Breaker 1600A 2000A 2500A or Switch (Q3) External Maintenance Bypass Cabinet’s Output Breaker 1600A 2000A 2500A or Switch (Q4) External Battery Cabinet’s 2200A 2800A 3400A Breaker (Q5) Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 65 Chapter 5 : Installation and Wiring NOTE: 1. Please follow local regulations to install proper conduits and bushings for cable protection. 2. Please refer to national and local electrical codes for acceptable protective devices and cable sizes. Table B.52.2 3. According to listed in the IEC 60364-5-52 standard, the Table 5-2 cables sizes listed in...
  • Page 66: Single Input To Dual Input Modification

    5.4.2 Single Input to Dual Input Modification NOTE: 1. Only authorized Delta engineers or service personnel can modify single input to dual input setup. 2. Please keep the removed components properly for future use. If you want to modify the UPS from dual input into single input, please use the removed screws and bus bars to connect the AC Input terminals (L1/ L2/ L3) and Bypass Input terminals (L1/ L2/ L3).
  • Page 67: Single Unit Wiring

    Chapter 5 : Installation and Wiring ⚫ 1000/ 1200kVA UPS Remove the three bus bars and twenty-four M10 screws connected between the AC Input terminals (L1/ L2/ L3) and the Bypass Input terminals (L1/ L2/ L3) shown in the following figure. (I/O Cabinet) (I/O...
  • Page 68 Connect the terminals to the external battery Battery Input cabinet(s). Please contact Delta service personnel Terminals (+/ -) for battery configurations. Connect the terminal to the external maintenance PE (protective earth) bypass cabinet’s GND terminal ( ). Terminal Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 69 NOTE: All breakers, switches and terminals listed in the above ‘Item’ column must be installed in the external maintenance bypass cabinet (user- supplied, handled and configured by Delta service personnel). Refer to 1.2 Connection Warnings for relevant information. 2. *...
  • Page 70: Single Input (Single Unit)

    1000/ 1200kVA UPS’s wiring terminals shown in Figure 2-13 Figure 2-14 Step 3 A. For top wiring, please remove the top covers. (I/O Cabinet) Remove the Four Top Covers Figure 5-12: 800kVA UPS_ Location of the Top Covers Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 71 Chapter 5 : Installation and Wiring (I/O Cabinet) Remove the Six Top Covers Figure 5-13: 1000/ 1200kVA UPS_ Location of the Top Covers B. For bottom wiring, please remove the bottom covers. (I/O Cabinet) (I/O Cabinet) Remove the Two Bottom Covers Figure 5-14: 800kVA UPS_ Location of the Bottom Covers...
  • Page 72 Connect the cables of the main AC source, output and external battery cabinet(s) to Table 5-3 Table the UPS and the external maintenance bypass cabinet. Please refer to 5.5 External Battery Cabinet Connection Warnings and the following diagrams to perform wiring. External Maintenance Bypass Cabinet Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 73 Chapter 5 : Installation and Wiring External Maintenance Bypass Cabinet Input Breaker or Bypass Input Terminals Main AC Source Switch (Q1) (L1/ L2/ L3/ N) Manual Bypass Breaker or Switch (Q3) Output Breaker or UPS Output Terminals Loads Switch (Q4) (L1/ L2/ L3/ N) Battery Input Terminals (+/ -)
  • Page 74 External External Distribution Battery Load Load Panel Cabinet Load Grounding UPS Grounding Load Grounding External Battery Cabinet Grounding Protective Earthing Figure 5-17: Grounding Diagram_ Single Unit Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 75: Dual Input (Single Unit)

    Chapter 5 : Installation and Wiring 5.4.3.2 Dual Input (Single Unit) When there are two AC power sources, single unit wiring procedures are as follows. Step 1 5.4.2 Single Input to Dual Input Modification Follow to modify the UPS from single input to dual input.
  • Page 76: Parallel Units Wiring

    Figure 4-1 4.3 Cable Routing location, refer to . For top or bottom cable entry, refer to for the Communication Interfaces NOTE: One parallel cable is provided in each UPS’s accessory package. Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 77 Chapter 5 : Installation and Wiring Parallel Cables Parallel Ports Parallel Ports Parallel Ports UPS) (Middle UPS(s)) (Last UPS) Figure 5-19: Parallel Port Connection_ Daisy Chain Method Step 3 Follow the table below to select proper Protective Earth (PE) cables to ground the parallel UPS units, external battery cabinet(s) and connected critical loads.
  • Page 78: External Battery Cabinet Connection Warnings

    2. Whether you use the lead-acid batteries or the lithium-ion batteries, please contact Delta service personnel for any battery/ battery cabinet’s setup and configurations. Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 79 Chapter 5 : Installation and Wiring WARNING:  1. Before performing battery/ battery cabinet installation, wiring and replacement, please turn off each external battery cabinet’s breaker (Q5) to completely disconnect the battery power from the UPS. 2. A battery can present a risk of electric shock and high short-circuit current.
  • Page 80 • Use a voltage meter to measure whether the total voltage is around 12.5 Vdc × the total number of batteries after the batteries are connected in series. The default battery quantity is 40 PCS of 12V batteries connected in series. • Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 81 Chapter 5 : Installation and Wiring Battery Input Terminals Protective Device External Battery Cabinet Figure 5-21: External Battery Cabinet Connection WARNING:  The electrolyte leakage of the batteries can lead to serious accidents. For safety concerns, you must insulate the batteries properly (using insulated trays or boxes) from the metal cabinets and racks.
  • Page 82 Table 5-5 is for 12 Vdc × 40 PCS of batteries (default). If you install a different number of batteries, please contact Delta service personnel for the protective device’s current and voltage values. 2. If you need to parallel multiple units of external battery cabinets, please contact Delta service personnel for relevant information.
  • Page 83 . These maximum values are suggested for general applications only. For the actual maximum values, the maximum short-circuit capacity of the on-site batteries must be taken into consideration. Please contact Delta customer service for relevant information. External Battery Cabinet’s Protective Device (Option 1) External...
  • Page 84 External Battery Cabinet’s Protective Device (Option 4) External Battery Cabinet DC Fuses (Optional) 2-Pole DC Circuit Breaker Figure 5-25: Installation of a 2-pole DC Circuit Breaker Connected in Series with Optional DC Fuses Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 85 For relevant information, please refer to the user manual of the lithium-ion batteries. Whether you use the lead-acid batteries or the lithium-ion batteries, please contact Delta service personnel for any battery/ battery cabinet’s setup and configurations. For common battery application, please install a protective device between each parallel UPS and its connected external battery cabinet(s).
  • Page 86 External Maintenance Bypass Cabinet Maintenance Bypass Static Switch BYPASS Rectifier Inverter MAIN LOAD External Maintenance Bypass Cabinet Maintenance Bypass Batteries BYPASS Static Switch Rectifier Inverter MAIN (Figure 5-26: Common Battery Diagram) Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 87: Installation Of Rodent Shields

    Chapter 5 : Installation and Wiring • External Battery Cabinet Alarm When any external battery cabinet connected to the UPS has the following problems, the UPS system will sound an alarm. Please see the table below. External Battery Cabinet Status Alarm Battery Abnormal - Reversed It sounds 0.5 seconds every second.
  • Page 88 (Rear of the UPS) Rodent Shield B (M5 Screw × 4) Rodent Shield B (M5 Screw × 4) Rodent Shield B (M5 Screw × 4) Figure 5-28: 800kVA UPS_ Install the Rodent Shields B Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 89: Installation Of 1000/1200Kva Ups's Rodent Shields

    Chapter 5 : Installation and Wiring Step 3 Install the rodent shields C at the bottom of two sides. (Front of the UPS) Rodent Shield C (M5 Screw × 2) Rodent Shield C (M5 Screw × 2) Figure 5-29: 800kVA UPS_ Install the Rodent Shields C 5.6.2 Installation of 1000/1200kVA UPS’s Rodent Shields Table 5-7: 1000/ 1200kVA UPS_ Rodent Shield Quantity...
  • Page 90 Rodent Shield D (M5 Screw × 4) Rodent Shield F (M5 Screw × 4) Rodent Shield A (M5 Screw × 4) Figure 5-30: 1000/ 1200kVA UPS_ Install the Rodent Shields A, D & F Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 91 Chapter 5 : Installation and Wiring Step 2 Install the rodent shields B, E and G at the rear bottom of the UPS. (Rear of the UPS) Rodent Shield B (M5 Screw × 4) Rodent Shield G (M5 Screw × 4) Rodent Shield E (M5 Screw ×...
  • Page 92 Install the rodent shields C at the bottom of two sides. (Front of the UPS) Rodent Shield C (M5 Screw × 2) Rodent Shield C (M5 Screw × 2) Figure 5-32: 1000/ 1200kVA UPS_ Install the Rodent Shields C Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 93: Chapter 6 : Ups Operation

    4. The external battery cabinet’s breaker (Q5) shown on the LCD is always ON by default. To enable the detection of the Q5 status via the LCD, please contact Delta customer service for additional configurations. • Pre Start-up Warnings 1. Before UPS operation, ensure that installation and wiring have been completely 5.
  • Page 94: Start-Up Procedures

    Switch ON the external maintenance bypass cabinet’s Output Breaker or Switch (Q4) Step 6 After the inverter turns on, the UPS will run in On-Line mode, the LCD screen will show as below, and the tri-color LED indicator will illuminate green. Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 95: Battery Mode Start-Up Procedures

    Chapter 6 : UPS Operation 6.2.2 Battery Mode Start-up Procedures WARNING:  6.1 Pre Start-up & Pre Turn-off Before turning on the UPS, please read Warnings thoroughly and ensure that the precautions and instructions have been followed. Step 1 Ensure that the external maintenance bypass cabinet’s Manual Bypass Breaker or Switch (Q3) is in the OFF position.
  • Page 96: Bypass Mode Start-Up Procedures

    Switch ON the external maintenance bypass cabinet’s Bypass Breaker or Switch (Q2) and Output Breaker or Switch (Q4). Step 3 Now, the UPS runs in Bypass mode, the LCD screen shows as below, and the tri-color LED indicator illuminates yellow. Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 97: Manual Bypass Mode Start-Up Procedures

    Chapter 6 : UPS Operation 6.2.4 Manual Bypass Mode Start-up Procedures WARNING:  6.1 Pre Start-up & Pre Turn-off 1. Before turning on/ off the UPS, please read Warnings thoroughly and ensure that the precautions and instructions have been followed. 2. In Manual Bypass Mode, make sure that all of the switches/ breakers (except for the external maintenance bypass cabinet’s Manual Bypass Breaker or Switch (Q3)) are in the OFF position before working on the UPS’s internal circuits to prevent electric shock.
  • Page 98 ) on the LCD screen. Step 6 After the inverter turns on, the UPS will run in On-Line mode, the LCD screen will show as below, and the tri-color LED indicator will illuminate green. Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 99: Eco Mode Start-Up Procedures

    Chapter 6 : UPS Operation 6.2.5 ECO Mode Start-up Procedures WARNING:  6.1 Pre Start-up & Pre Turn-off Before turning on the UPS, please read Warnings thoroughly and ensure that the precautions and instructions have been followed. Step 1 Ensure that the external maintenance bypass cabinet’s Manual Bypass Breaker or Switch (Q3) is in the OFF position.
  • Page 100 After the inverter turns on and the system confirms that the bypass voltage is normal, the UPS will automatically transfer to ECO mode to let the bypass supply power, the LCD screen will show as below, and the tri-color LED indicator will illuminate green. Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 101: Frequency Conversion Mode Start-Up Procedures

    Chapter 6 : UPS Operation 6.2.6 Frequency Conversion Mode Start-up Procedures WARNING:  6.1 Pre Start-up & Pre Turn-off 1. Before turning on the UPS, please read Warnings thoroughly and ensure that the precautions and instructions have been followed. 2. Frequency Conversion mode is only applicable to single UPS but not to parallel UPSs.
  • Page 102 After the inverter turns on, the UPS will run in Frequency Conversion mode, the output frequency will be the same as the setup value, the LCD screen will show as below, and the tri-color LED indicator will illuminate green. Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 103: Clean Mode Start-Up Procedures

    Chapter 6 : UPS Operation 6.2.7 Clean Mode Start-up Procedures NOTE: Clean mode is optional. Only trained Delta engineers can enable this function. If needed, please contact Delta customer service. WARNING:  6.1 Pre Start-up & Pre Turn-off Before turning on the UPS, please read...
  • Page 104 , correct power factor and reduce bypass reactive current to improve overall power quality. The LCD screen shows as below, and the tri-color LED indicator illuminates green. Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 105: Turn-Off Procedures

    Chapter 6 : UPS Operation Turn-off Procedures 6.3.1 On-Line Mode Turn-off Procedures WARNING:  6.1 Pre Start-up & Pre Turn-off Before turning off the UPS, please read Warnings thoroughly and ensure that the precautions and instructions have been followed. Step 1 Tap the ON/ OFF Button ( ) to shut down the UPS’s inverter.
  • Page 106: Battery Mode Turn-Off Procedures

    (Q5), and the LCD and tri-color LED indicator will be off. 6.3.4 Manual Bypass Mode Turn-off Procedures WARNING:  1. Ensure that the LCD, all LED indicators and fans are OFF. 2. Check that all the switches, breakers and power are OFF. Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 107: Eco Mode Turn-Off Procedures

    Chapter 6 : UPS Operation In Manual Bypass mode, the LCD and tri-color LED indicator are both OFF. To completely shut down the UPS, switch OFF the external maintenance bypass cabinet’s Manual Bypass Breaker or Switch (Q3). 6.3.5 ECO Mode Turn-off Procedures WARNING: ...
  • Page 108: Clean Mode Turn-Off Procedures

    6.3.7 Clean Mode Turn-off Procedures NOTE: Clean mode is optional. Only trained Delta engineers can enable this function. If needed, please contact Delta customer service. WARNING:  6.1 Pre Start-up & Pre Turn-off Before turning on the UPS, please read...
  • Page 109: Start-Up & Turn Off Procedures For Parallel Units

    Chapter 6 : UPS Operation Start-up & Turn off Procedures for Parallel Units WARNING:  6.1 Pre Start-up & Pre Turn-off 1. Before turning on the UPS, please read Warnings thoroughly and ensure that the precautions and instructions have been followed. 2.
  • Page 110 Ensure that the output voltage difference between each parallel UPS is below 3V. Only authorized Delta engineers or service personnel can check the output voltage difference, or it must be done under the supervision of authorized Delta engineers or service personnel.
  • Page 111: Chapter 7 : Lcd Display & Settings

    Chapter 7 : LCD Display & Settings Chapter 7 : LCD Display & Settings LCD Display Hierarchy Figure 7-1 Please refer to for an overview of all the LCD items. For some of the items marked with an asterisk, they will show up only under certain conditions. Please refer to the note below for details.
  • Page 112 Common Battery HTTP / HTTPS (Level 2) (Level 2) Dry Contact Remote User Setting Setting Privilege/ Account Name/ Password INPUT DRY CONTACT: 1 ~ 4 Login Limitation OUTPUT DRY CONTACT: 1 ~ 6 Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 113 Chapter 7 : LCD Display & Settings (Level 1) (Level 1) (Level 1) LOG IN EVENT LOG MAINTENANCE (Level 2) (Level 2) Log-in ID: Warning User Warning (Level 2) (Level 2) Log-in ID: Historical Administrator Event Historical Event (Level 2) Statistics In Battery Mode (times/ hours) In Bypass Mode (times/ hours)
  • Page 114: How To Turn On The Lcd

    To display the item(s), you have to log in as Administrator. Please refer 7.4 Password Entry The item will show up only when you use the Delta lithium-ion batteries and have installed the optional multifunctional communication card (MFC) in the SMART slot.
  • Page 115: Introduction Of Touch Panel And Function Keys

    Chapter 7 : LCD Display & Settings Step 2 A short while later, the Main Screen will appear with User Login status. If the ON/ OFF Button ( ) does not appear on the screen, please log in as Administrator first, and then go to General Setting User On/ Off Button...
  • Page 116 ✓ ✓ 7.4 Password Entry Please refer to Indicates Administrator login status. Tap the icon to change the login ✓ ✓ permission. Please refer to Password Entry Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 117 Chapter 7 : LCD Display & Settings Text/ Button Symbol Digital Function Display Icon/ Text Display Description (Yes or (Yes or (Yes or 1. Historical event screen shortcut button ( ✓ ✓ 2. When the icon is blue ( ), it means there is no warning event.
  • Page 118 Normal/ Flashing Green & Gray: Battery Mode/ Flashing Red & Gray: Battery Not Connected). 2. Shows battery remaining capacity ✓ ✓ ✓ (%) and battery remaining time (minutes). 3. Battery status screen shortcut button. Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 119 Chapter 7 : LCD Display & Settings Text/ Button Symbol Digital Function Display Icon/ Text Display Description (Yes or (Yes or (Yes or Indicates bypass static switch status ✓ (Green: ON/ Gray: Abnormal or OFF). Indicates rectifier status (Green: ✓ Normal/ Gray: Waiting or OFF).
  • Page 120: Password Entry

    → enter the Administrator password (contact service personnel for the default password) → the icon appears, indicating the Administrator login is successful. 3. To change the Administrator password, please go to → General Setting → User → Admin Password (4 digits). Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 121: Check Kilowatt-Hour

    Chapter 7 : LCD Display & Settings Check Kilowatt-Hour Path: → Main Input → kWh icon ( Tap the kWh icon ( ), and you can check the kWh statistics of the UPS main input in the following window.
  • Page 122: Ups Settings

    Bypass Voltage (Max.) Set up the bypass output’s maximum voltage. Bypass Voltage (Min.) Set up the bypass output’s minimum voltage. Set up the bypass output’s voltage range in ECO ECO Voltage Range mode. Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 123: Mode Setting

    Clean Mode reactive current to improve overall power quality. NOTE: Clean mode is optional. Only trained Delta engineers can enable this function. If needed, please contact Delta customer service.
  • Page 124: Output Setting

    Battery mode to On-Line mode. The setup will help System Sequential the generator to handle the whole loads in a sequential Start manner to avoid generator shutdown due to sudden inrush current. Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 125: Battery & Charging Setting

    If you use the Delta lithium-ion batteries, please set up the battery type as 'LiB (Integration)'. The item 'LiB (Integration)' will appear on the LCD only if you use the Delta lithium-ion batteries with the optional multifunctional communication card (MFC) being installed in the SMART slot.
  • Page 126 High Temperature Enable or disable the high temperature alarm. If enabled, Alarm set up the temperature. Installation Date Record the battery installation date. Next Replacement Set up the battery replacement date. Date Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 127: Parallel Setting

    Chapter 7 : LCD Display & Settings 7.6.5 Parallel Setting Path: → Parallel Setting Item Description The UPSs in parallel connection must be assigned the same parallel group ID no. in order to let the outputs of the parallel UPSs be put in parallel connection and let the Parallel Group ID loads be evenly distributed among the parallel units.
  • Page 128: General Setting

    21. General Alarm 7.6.7 General Setting Path: → General Setting Item Sub Item Description Date Format Select the date format. DATE/ Date Set up the date. TIME Time Set up the time. Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 129 Set up the MODBUS mapping table (default: Table MODBUS Mapping Table Table A: Compatible with Delta MODBUS card. Table B: Applicable to DPS Gen2 MODBUS. Dust Filter If you have installed any dust filter, please select Installation 'Enable';...
  • Page 130: Ip Setting

    'Reset' to reset the system. After the system is reset, please tap the ON/ OFF Button ( ) to start up the UPS. Force Equalized Manually force the UPS to run in auto equalized charge mode Charge to charge the batteries. Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 131: 7.6.10 Network Service

    Chapter 7 : LCD Display & Settings Item Description Manually force the UPS to switch from bypass to inverter Force Bypass to when the inverter keeps staying in the soft-start status and is Inverter unable to transfer to On-Line mode successfully. Execute ‘Transfer to Bypass’...
  • Page 132: Historical Event

    Shows how long and how many times the UPS runs in Bypass In Bypass Mode mode. Operation Time Shows how long the UPS has operated. 7.7.5 Clear To clear the statistics, please refer to Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 133: Test

    7.7.6 Advanced Diagnosis Path: → Advanced Diagnosis This is an optional function. If you would like to access this page, please contact Delta customer service. 7.7.7 Version & S/N NOTE: To operate the UPSs in parallel, please make sure all the versions below are the same for each parallel unit.
  • Page 134 Check and update the MCU or MCU2 firmware PM #_ MCU/ MCU2 version of a specific power module’s PFC. Check and update the MCU version of a specific PM #_ MCU power module’s CHG. Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 135: Chapter 8 : Optional Accessories

    Function on the LCD Screen 7.6.4 Battery & Charging Management Setting System (BMS) NOTE: The quantity of BMS to be installed depends on how many external battery cabinets (lead-acid batteries) are connected to the UPS. For BMS installation, please contact Delta customer service.
  • Page 136: Ems Function On The Lcd Screen

    Item Function If you use the Delta lithium-ion batteries, you must purchase and install the multifunctional communication Figure 4-1 card (MFC) in the SMART slot shown in monitor the battery status via the UPS’s LCD. For relevant 8.3 MFC Function on the LCD...
  • Page 137 Chapter 8 : Optional Accessories Color Item Descriptions (Status) 1. ID # represents each EMS 1000 Green (EnviroProbe) device which is connected (Normal) and set as 'Enable'. Yellow 2. Shows the integrated status of each EMS (Warning) 1000 (EnviroProbe) device. The integrated Red (Alarm) status is determined by the most severe status among Temperature (°C), Humidity...
  • Page 138 4. To enable the EMS function, you have to set up relevant items on the LCD after connecting the optional EMS 1000 (EnviroProbe) to the UPS.  Path: → EMS Setting (Administrator login is required) Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 139 Chapter 8 : Optional Accessories NOTE: The default values are shown in the figures above. Item Sub Item Description Set the ID # (ID 0/ ID 1/ …/ ID 15) according to the ID DIP switch setting of the EMS 1000 (EnviroProbe) device.
  • Page 140: Bms Function On The Lcd Screen

    Cell Voltage, String Voltage and Ambient Temperature. You can also set up the following items. These settings must be carried out by qualified service personnel. Please contact Delta customer service for assistance. Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 141 Temperature and Ambient Temperature. You can also set up the following items. These settings must be carried out by qualified service personnel. Please contact Delta customer service for assistance. NOTE: The Alarm Threshold Values (High & Low) are defined by the service personnel during the installation process of the optional battery management system (BMS).
  • Page 142: Mfc Function On The Lcd Screen

    MFC Function on the LCD Screen The PAGE 3 & MFC screens (see the figures below) will appear on the LCD only if you use the Delta lithium-ion batteries with the optional multifunctional communication Figure 4-1 (MFC) card being installed in the SMART slot (see ).
  • Page 143 Chapter 8 : Optional Accessories In the screen shown above, you can view the corresponding Cabinet, String, Voltage, Current, Min Module SOH, Max. Cell Volt, Min Cell Volt, Max Temp and Min Temp. Path: → General Setting (Administrator login is required) ...
  • Page 144: Chapter 9 : Maintenance

    UPS. If not, please replace abnormal fans. NOTE: Please ask your local dealer or customer service for more maintenance infor- mation. Do not perform maintenance if you are not trained for it. Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 145: Appendix 1 : Technical Specifications

    Appendix 1 : Technical Specifications Appendix 1 : Technical Specifications Model DPS-800K DPS-1000K DPS-1200K 800kVA/ 1000kVA/ 1200kVA/ UPS Capacity 800kW 1000kW 1200kW Nominal 220/380 Vac, 230/400 Vac, Voltage 240/415 Vac (3Φ4W + G) Voltage Range 176/304 ~ 276/478 Vac* (full load) Current Input Harmonic...
  • Page 146 0 ~ 40°C (32 ~ 104°F) Temperature Relative Environment 95% (non-condensing) Humidity Audible Noise < 80 dBA* Ingress Protection (IP) IP20 Class Parallel Yes (up to 8 units) Redundancy Emergency Others Power Off Battery-start Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 147 Appendix 1 : Technical Specifications Model DPS-800K DPS-1000K DPS-1200K 800kVA/ 1000kVA/ 1200kVA/ UPS Capacity 800kW 1000kW 1200kW 1800 × 900 Dimensions 2450 × 900 × 2000 mm × 2000 mm (W × D × H) (70.87" × 35.43" (96.45" × 35.43" × 78.74") Physical ×...
  • Page 148: Appendix 2 : Warranty

    The User Manual must be carefully followed. Seller makes no representation or warranty as to the suitability or fitness of this product for any specific application. No. : 501328600404 Version : V 4.4 Release Date : 2024_08_16 Delta UPS DPS Gen2 800/ 1000/ 1200 kVA...
  • Page 149 T +81-3-5733-1111 +86 21 5863 9595 E jpstps@deltaww.com E ups.china@deltaww.com Singapore South Korea Delta Electronics Int’l (Singapore) Pte Ltd. Delta Electronics (Korea), Inc. 17 Kallang Junction, #01-01, TRION, 1511, Byucksan Digital Valley 6-cha, Gasan-dong, Geumcheon-gu, Singapore 339274 Seoul, Korea, 153-704...
  • Page 150 5013286004...

This manual is also suitable for:

Ultron seriesDps gen2 series

Table of Contents