Page 5
Warranty Tektronix warrants that this product will be free from defects in materials and workmanship for a period of one (1) year from the date of shipment. If any such product proves defective during this warranty period, Tektronix, at its option, either will repair the defective product without charge for parts and labor, or will provide a replacement in exchange for the defective product.
Do not operate in an explosive atmosphere. Keep product surfaces clean and dry. Provide proper ventilation. Refer to the manual’s installation instructions for details on installing the product so it has proper ventilation. WVR4000 and WVR5000 Waveform Rasterizers User Manual...
Page 10
DANGER indicates an injury hazard immediately accessible as you read the marking. WARNING indicates an injury hazard not immediately accessible as you read the marking. CAUTION indicates a hazard to property including the product. The following symbol(s) may appear on the product: WVR4000 and WVR5000 Waveform Rasterizers User Manual...
The symbol shown below indicates that this product complies with the European Union’s requirements according to Directive 2002/96/EC on waste electrical and electronic equipment (WEEE). For information about recycling options, check the Support/Service section of the Tektronix Web site (www.tektronix.com). Perchlorate Materials This product contains one or more type CR lithium coin cell batteries.
This manual describes the installation and basic operation of the following instruments: WVR5000 series waveform rasterizers WVR4000 series waveform rasterizers Key Features Tektronix waveform rasterizers can help you monitor SD SDI or HD SDI signals. The following table includes key features of these instruments. Feature Description Flexible tile displays: Full, Quad TIle (4-Tile): View four measurement displays at once, one in each tile.
Page 13
Preface Feature Description Error tracking Configurable alarms and error logging. Ground closure Signal sent out of the GCI port of the instrument for a remote notification that an alarm condition occurred. WVR4000 and WVR5000 Waveform Rasterizers User Manual...
Option D5. Adds 5 years of Calibration Data Report (when ordered with option C5). Option R3. Adds 3 years of Repair Service (including the period under warranty). Option R5. Adds 5 years of Repair Service (including period under warranty). viii WVR4000 and WVR5000 Waveform Rasterizers User Manual...
WFM, Database technical WVR, and AMM reference instruments Service manual Optional manual supporting module-level servicing of the instrument Conventions Used in this Manual The following icons are used throughout this manual: Sequence Step WVR4000 and WVR5000 Waveform Rasterizers User Manual...
Page 16
Preface WVR4000 and WVR5000 Waveform Rasterizers User Manual...
(including the anti-static bag) in case you need to ship the instrument. Accessories The table below shows which items are standard accessories and which items are optional accessories. Check the Tektronix Web site (www.tektronix.com) for the most current information on accessories.
3. Terminate the loop-through on the SDI connector you will use on the instrument. 4. Connect the cable from the serial source output to the one of the SDI inputs on the rear panel of the instrument. WVR4000 and WVR5000 Waveform Rasterizers User Manual...
The Power button performs the following functions when connected to a 12 V DC input. Press the Power button to turn on the instrument. Press the Power button again to turn off the instrument. WVR4000 and WVR5000 Waveform Rasterizers User Manual...
5. Connect the other end of that cable to one of the SDI inputs on the rear panel of the instrument. 6. Connect a cable from a serial receiver to the SDI loop-through on the instrument. WVR4000 and WVR5000 Waveform Rasterizers User Manual...
Page 21
SDI or reference connectors in end-of-link setups must be 75 Ω and DC coupled (good return loss extends to DC). An appropriate termination would be a 75 Ω End of Line terminator, Tektronix part number 011-0163-XX. Compatibility of BNC Center Pins Most video equipment BNC connectors, whether 50 Ω...
CONFIG > Display Settings > Thumbnail menu. 3. Push the Thumbnail button again to turn off the picture thumbnail. NOTE. The Picture Thumbnail is available for all displays except Picture. WVR4000 and WVR5000 Waveform Rasterizers User Manual...
Page 23
In the latter case, each character shows the status of a specific channel: - for not present and p for present. Timecode Readout A readout showing the selected time-code value. WVR4000 and WVR5000 Waveform Rasterizers User Manual...
Instrument-wide settings. The parameters in the Configuration menu are instrument-wide settings. The configuration menu controls settings that are changed only occasionally, such as changing waveform color or setting the network address. WVR4000 and WVR5000 Waveform Rasterizers User Manual...
Page 25
Power button Press to turn the instrument on or off. Main button Access to 4-Tile (Quad Tile) mode and to the USB drive. Demonstrated in 4-Tile and Full-Tile Modes (See page 15.) WVR4000 and WVR5000 Waveform Rasterizers User Manual...
2. SDI A. The Digital A component serial digital input is compensated for 75 Ω and requires termination. 3. SDI B. The Digital B component serial digital input is compensated for 75 Ω and requires termination. WVR4000 and WVR5000 Waveform Rasterizers User Manual...
AUDIO - display of level (meters) and of a phase (plot) for monitoring audio signals STATUS - Extensive views of signal status, Error Log, and Timing display MAIN - provides access to USB drive, 4-Tile mode, and Full-Tile mode WVR4000 and WVR5000 Waveform Rasterizers User Manual...
1. Push and hold the display button for which the settings need to be set or modified. 2. When the menu pops up, navigate through and make your selections as described in the steps that follow. WVR4000 and WVR5000 Waveform Rasterizers User Manual...
HD or SD. SD (WFM4000 series): Connect SD signal only. 2. Press the Input button corresponding to the input that you want (SDI Input A shown). 3. Select a display to view the input. WVR4000 and WVR5000 Waveform Rasterizers User Manual...
Tile 3, and then press the right arrow key to navigate to the submenu. The available displays will be shown in the submenu. Select the one you want to display in tile 3 using the up and down arrow keys. WVR4000 and WVR5000 Waveform Rasterizers User Manual...
Waveform/Vector (WFM & VEC) Display Overlay feature, Gain, Sweep, and Magnification apply to the active display. A lit front-panel button denotes an active display. Gain, Sweep, and Magnification do not apply to all display types. NOTE. WVR4000 and WVR5000 Waveform Rasterizers User Manual...
Page 33
2 Line and 2 Field. To Set Magnification 1. Press the WFM button. 2. Press and hold the MAG button to display the magnification settings. 3. Select the setting (Best View, x10, x20, x30) of your choice. WVR4000 and WVR5000 Waveform Rasterizers User Manual...
2. In the pop-up menu, navigate to Display Overlay and select WFM & VEC. The Vector display will be overlaid on the WFM display. 3. Press the WFM button to dismiss the pop-up menu. WVR4000 and WVR5000 Waveform Rasterizers User Manual...
Preset and select the name to which you want to map the new preset. This name corresponds to one of the six numbered preset buttons. The setup will be stored for later recall. WVR4000 and WVR5000 Waveform Rasterizers User Manual...
Live + Frozen allows comparisons and matching. (Status and Audio displays do not support this mode.) To Halt Display Update Push the FREEZE button to stop a display update. For most displays, this will stop updates. WVR4000 and WVR5000 Waveform Rasterizers User Manual...
Page 37
Cursors track the live trace, so they may not be correctly registered on a frozen trace. If you change parameters such as position, sweep rate, or gain, then the cursors may not be accurate relative to a frozen trace. WVR4000 and WVR5000 Waveform Rasterizers User Manual...
first highlight it. The following procedures help you to navigate through the configuration menu. To Traverse the Menu Panes 1. Press the CONFIG button to display the Configuration menu. The Configuration menu is displayed on the top or bottom half of the screen. WVR4000 and WVR5000 Waveform Rasterizers User Manual...
Context-sensitive. The topic displayed depends on what is displayed when the online help is selected or what control is operated after help is selected. Navigable. The Contents and Topic Selector panes, along with Links within the topics, provide access to topics. WVR4000 and WVR5000 Waveform Rasterizers User Manual...
Page 40
2. Highlight a link using the GENERAL knob or the up/down arrow key. 3. Press SEL to jump to the linked-to topic. 4. Press the left-arrow key to go back to the previous topic. WVR4000 and WVR5000 Waveform Rasterizers User Manual...
2. Use the Horizontal knob to adjust the volume. 3. Press and hold the AUDIO button to display the Audio menu. 4. Select Phase/Headphone Pair, and then select the headphone source of your choice. WVR4000 and WVR5000 Waveform Rasterizers User Manual...
5. Set BAR TARGETS to match your input signal. 6. Select Center Waveform, and press SEL if you want to center the waveform. 7. Press the VECT button to close the pop-up menu. WVR4000 and WVR5000 Waveform Rasterizers User Manual...
Page 43
The + tic marks on the graticule indicate the following timing errors: 1080p 50, 59.94, 60 (dual link Tic mark SD timing error (ns) HD timing error (ns) formats) timing error (ns) 0 marks 13.5 6.75 13.5 Luma sample Chroma sample WVR4000 and WVR5000 Waveform Rasterizers User Manual...
RGB component gamut errors. Split Diamond. Use to reveal hard-to-find black gamut errors. Arrowhead. Use to detect composite gamut errors, without employing a composite encoder. 5. Press the GAMUT button to close the menu. WVR4000 and WVR5000 Waveform Rasterizers User Manual...
Errors in green amplitude affect both diamonds equally, while blue amplitude errors affect only the top diamond and red errors affect only the bottom diamond. WVR4000 and WVR5000 Waveform Rasterizers User Manual...
Page 46
Use the PICT display to examine the signal (turn on gamut bright-ups in the Display Settings submenu of the Configuration menu) Use the Arrowhead % setting (found in the Gamut Thresholds submenu of the Configuration menu) to specify a percentage of the screen to ignore for gamut violations. WVR4000 and WVR5000 Waveform Rasterizers User Manual...
7.5 IRE for NTSC and 0 mV for PAL. Usage Notes To adjust the IRE level limits, do the procedure Adjusting Gamut Limits. (See page 34.) To automate this check, do the procedure Automating Gamut Checks. (See page 33.) WVR4000 and WVR5000 Waveform Rasterizers User Manual...
Another useful Arrowhead function is a measure of how well the active video signal is using the dynamic range of the video channel. A properly adjusted signal should be centered in the arrowhead graticule and have transitions that approach all the limits. WVR4000 and WVR5000 Waveform Rasterizers User Manual...
Press SEL button to toggle the alarm on (X) or off. 4. When you have configured the Alarms, move to the Return box and select it. WVR4000 and WVR5000 Waveform Rasterizers User Manual...
3. Press the SEL button to enter the submenu, and then use the arrow keys and SEL button (and General knob, when indicated) to select and set the various thresholds. Note that you can also reset thresholds to defaults. WVR4000 and WVR5000 Waveform Rasterizers User Manual...
Timing Display Timing Display The Timing display is a Tektronix proprietary display that simplifies measuring the timing difference between two signals as the timing is corrected. You can access this display from the STATUS button. Using the Timing display enables you to easily compare and correct the timing between two signals.
Page 52
(offset) relative to the cross-hair. (See Figure 2.) Figure 2: Timing display of integer multiples of reference rates WVR4000 and WVR5000 Waveform Rasterizers User Manual...
Page 53
five frames of the reference. Because this allows for five possible ways to measure timing between these two signals, the timing display shows four circles, with emphasis and readouts as previously described above. WVR4000 and WVR5000 Waveform Rasterizers User Manual...
6. Specify which inputs will be allowed to generate alarms. 7. Select the Return box to return to the Configuration menu. 8. Repeat steps 4 through 7 for other audio inputs, as needed. WVR4000 and WVR5000 Waveform Rasterizers User Manual...
Audio display and popup the Audio menu. 2. Use the Arrow Keys and SEL button to make selections in the steps that follow. 3. Select Audio Input and then select one of the audio input options shown. WVR4000 and WVR5000 Waveform Rasterizers User Manual...
Lissajous Soundstage or X-Y orientation for the Lissajous signal. 4. Select the phase pair that has to be displayed from the Phase/Headphone Pair. 5. Set the Audio Input to match the signal that you are checking. WVR4000 and WVR5000 Waveform Rasterizers User Manual...
Page 59
The following response times of the correlation meters can be set from the Configuration menu. Speed setting Response averaging time (s) Speed setting Response averaging time (s) 0.0167 0.0333 0.0667 0.1333 0.2667 0.5333 8 (default) WVR4000 and WVR5000 Waveform Rasterizers User Manual...
4. Choose from the SMPTE or ITU standards. The selection you choose will be the graticule used when AUTO is chosen for any of the four Safe Area Graticules, accessed in the Picture menu. WVR4000 and WVR5000 Waveform Rasterizers User Manual...
Page 61
Graticules Configuration menu. (See the procedure To Configure Safe Area Graticules, step 5.) 4. Repeat step for each Safe Area selection. 5. Press the PICT button again to close the pop-up menu. WVR4000 and WVR5000 Waveform Rasterizers User Manual...
Page 62
Safe Area Graticules can globally be configured to comply to accepted standards in the Configuration menu. Custom selections for vertical and horizontal size and offset of the Save Areas can be set in the Configuration menu. WVR4000 and WVR5000 Waveform Rasterizers User Manual...
5. Note that the alarms in the category you select appear to the right as you highlight the alarm category. Press SEL to display a table that allows you to set the responses for individual alarms. WVR4000 and WVR5000 Waveform Rasterizers User Manual...
Page 64
For each available alarm, you can select up to four of the responses listed. If you do not select a notification method for an error, you will not be notified when the error occurs. WVR4000 and WVR5000 Waveform Rasterizers User Manual...
Page 65
To start, select Audio Inputs/Outputs in the Configuration menu. 5. Select each input shown in the box to individually enable its alarms. In this example, AES A is selected. WVR4000 and WVR5000 Waveform Rasterizers User Manual...
Page 66
Silence Level: the level below which audio is considered not present. Silence Duration: the length of audio silence time allowed. Over Level: the too-loud audio level. Over Duration: the length of time limit for the too-loud audio. WVR4000 and WVR5000 Waveform Rasterizers User Manual...
OK (green) Alarm is enabled for reporting and has not detected errors for at least 5 seconds. Error (yellow) Alarm condition cleared for less than 5 seconds. Error (red) Alarm triggered now. WVR4000 and WVR5000 Waveform Rasterizers User Manual...
4. Click on Sort by DATE to find the most the recent software release. 5. Download the file and save it to a USB memory device that is compatible with your instrument. 6. Save the package into a directory named WfmUpgrd. WVR4000 and WVR5000 Waveform Rasterizers User Manual...
Page 69
4. Extract the following files: transfer.exe, firmware.pkg and readme.txt. 5. From the CONFIG > NETWORK SETTINGS menu, write down the number listed for the IP Address. This address will also appear on the update screen. WVR4000 and WVR5000 Waveform Rasterizers User Manual...
Page 70
Enter on your PC keyboard to start the software upgrade. If you will not be updating another instrument, press Enter to exit the transfer utility. WVR4000 and WVR5000 Waveform Rasterizers User Manual...
Page 71
To verify the functional performance of your instrument, perform the Incoming Inspection procedures. NOTE. See the Readme.txt file that is included with the software-upgrade package to determine whether all of the current Configuration menu and instrument-mode settings were preserved through upgrading. WVR4000 and WVR5000 Waveform Rasterizers User Manual...
Page 72
Upgrading Instrument Software WVR4000 and WVR5000 Waveform Rasterizers User Manual...