Page 1
OPERATION AND PARTS MANUAL MODEL QP3Ti TRASH PUMP (HONDA iGX270UT2QZMD GASOLINE ENGINE) Revision #1 (05/07/18) To find the latest revision of this publication, visit our website at: www.multiquip.com THIS MANUAL MUST ACCOMPANY THE EQUIPMENT AT ALL TIMES.
Wiring Locator — Control Panel ......35 Explanation Of Code In Remarks Column..... 36 Suggested Spare Parts ......... 37 NOTICE Specifications and part numbers are subject to change without notice. PAGE 4 — QP3Ti TRASH PUMP • OPERATION AND PARTS MANUAL — REV. #1 (05/07/18)
NOTICE All orders are treated as Standard Orders and will ship the same day if received prior to 3PM PST. WE ACCEPT ALL MAJOR CREDIT CARDS! QP3Ti TRASH PUMP • OPERATION AND PARTS MANUAL —REV. #1 (05/07/18) — PAGE 5...
COULD result in DEATH or SERIOUS INJURY. CAUTION Indicates a hazardous situation which, if not avoided, COULD result in MINOR or MODERATE INJURY. NOTICE Addresses practices not related to personal injury. PAGE 6 — QP3Ti TRASH PUMP • OPERATION AND PARTS MANUAL — REV. #1 (05/07/18)
Page 7
Also, know the phone numbers of the nearest ambulance, doctor and fi re department. This information will be invaluable in the case of an emergency. QP3Ti TRASH PUMP • OPERATION AND PARTS MANUAL —REV. #1 (05/07/18) — PAGE 7...
Page 8
ALWAYS use extreme caution when working with persons in the general area of the pump. fl ammable liquids. PAGE 8 — QP3Ti TRASH PUMP • OPERATION AND PARTS MANUAL — REV. #1 (05/07/18)
Page 9
If the battery liquid (dilute sulfuric acid) comes into contact with clothing or skin, rinse skin or clothing immediately with plenty of water. QP3Ti TRASH PUMP • OPERATION AND PARTS MANUAL —REV. #1 (05/07/18) — PAGE 9...
Page 10
The label must remain with the engine for its entire life. If a replacement emission label is needed, please contact your authorized engine distributor. PAGE 10 — QP3Ti TRASH PUMP • OPERATION AND PARTS MANUAL — REV. #1 (05/07/18)
51.1 in (1300 mm) 20.6 in. (525 mm) 51.6 in. (1312.7mm) 26.9 in. (685 mm) 40.2 in. (1022.7 mm) 28.8 in. (732 mm) 30.3 in. (770 mm) QP3Ti TRASH PUMP • OPERATION AND PARTS MANUAL —REV. #1 (05/07/18) — PAGE 11...
66.8 lbs (30.3 Kg.) Engine power ratings are calculated by the individual engine manufacturer and the rating method may vary among engine manufacturers. Multiquip Inc. and its subsidiary companies makes no claim, representation or warranty as to the power rating of the engine on this equipment and disclaims any responsibility or liability of any kind whatsoever with respect to the accuracy of the engine power rating.
8,000 (2,438) as close to the water as possible. 10,000 (3,048) PUMP SUPPORT The pump should always be placed on solid stationary ground in a level position. QP3Ti TRASH PUMP • OPERATION AND PARTS MANUAL —REV. #1 (05/07/18) — PAGE 13...
For quick disconnect connections, an optional also store tools necessary for pump use, setup, and coupler (A300A) is necessary. Contact MQ Parts maintenance (optional). Department for ordering assistance. QP3Ti TRASH PUMP • OPERATION AND PARTS MANUAL —REV. #1 (05/07/18) — PAGE 15...
The iGX engine design does not require a choke lever. 2. Fuel Valve Lever — OPEN to let fuel flow, CLOSE to stop the flow of fuel. PAGE 16 — QP3Ti TRASH PUMP • OPERATION AND PARTS MANUAL — REV. #1 (05/07/18)
4. Auto/Manual Switch — Used to select either Auto or Manual mode of operation. 5. Flow Control Switch — Used to adjust flow volume (this switch only works in Manual mode). QP3Ti TRASH PUMP • OPERATION AND PARTS MANUAL —REV. #1 (05/07/18) — PAGE 17...
Green Lamp OFF Red Lamp FLASHING 5 times, OFF for 3 sec Circuit or ECU error in then repeats control box. Green Lamp OFF PAGE 18 — QP3Ti TRASH PUMP • OPERATION AND PARTS MANUAL — REV. #1 (05/07/18)
3. When refueling, be sure to use a strainer for filtration. DO NOT top-off fuel. Wipe up any spilled fuel immediately! QP3Ti TRASH PUMP • OPERATION AND PARTS MANUAL —REV. #1 (05/07/18) — PAGE 19...
3. After the engine has started, turn the flow control switch to the desired flow volume (Figure 12). FLOW CONTROL SWITCH Figure 10. Operation Mode Selection Figure 12. Flow Control Switch QP3Ti TRASH PUMP • OPERATION AND PARTS MANUAL —REV. #1 (05/07/18) — PAGE 21...
Page 22
When the water reaches the set high level again, pump starts draining again. PAGE 22 — QP3Ti TRASH PUMP • OPERATION AND PARTS MANUAL — REV. #1 (05/07/18)
Page 23
One is for the high level (TOP) and the other for low level (BOTTOM). 3. Set the top (drain) and bottom (stop) water levels you expect to control with the float switches (Figure 15). QP3Ti TRASH PUMP • OPERATION AND PARTS MANUAL —REV. #1 (05/07/18) — PAGE 23...
This prevents backflow and allows for faster priming when the engine is restarted. PAGE 24 — QP3Ti TRASH PUMP • OPERATION AND PARTS MANUAL — REV. #1 (05/07/18)
SHOULD BE BETWEEN INTO 25 FEET OF LIFT -25 AND -20 IN. HG. AT SEA LEVEL. -100 in. Hg PUMP VACUUM TESTER WIKA Figure 17. Pump Vacuum Tester QP3Ti TRASH PUMP • OPERATION AND PARTS MANUAL —REV. #1 (05/07/18) — PAGE 25...
Refer to the HONDA shop Manual for service procedures. 3. For commercial use, log hours of operation to determine proper maintenance intervals. NOTICE Refer to manufacturer engine manual for specific servicing instructions. PAGE 26 — QP3Ti TRASH PUMP • OPERATION AND PARTS MANUAL — REV. #1 (05/07/18)
Page 27
Table 5. Engine oil capacity is 1.16 quarts (1.1 liters). DO NOT over fill. 4. Install drain bolt with sealing washer and tighten securely. Figure 19. Engine Oil (Draining) Figure 20. Engine Air Cleaner QP3Ti TRASH PUMP • OPERATION AND PARTS MANUAL —REV. #1 (05/07/18) — PAGE 27...
Page 28
5. If the spark arrester is damaged and has breaks or holes, replace with a new one. 6. Reinstall the spark arrester and muffler protector in reverse order of disassembly. Figure 21. Spark Arrester Removal PAGE 28 — QP3Ti TRASH PUMP • OPERATION AND PARTS MANUAL — REV. #1 (05/07/18)
(new or used) through the discharge opening on the pump and crank the engine several times. This will prevent excessive corrosion and also keep the mechanical seal lubricated. QP3Ti TRASH PUMP • OPERATION AND PARTS MANUAL —REV. #1 (05/07/18) — PAGE 29...
Red light flashes 5 times ECU error? Contact Multiquip. and repeats. Red light flashes 2 times, turns OFF for 3 sec and Harness disconnected? Repair harness connection. repeats PAGE 30 — QP3Ti TRASH PUMP • OPERATION AND PARTS MANUAL — REV. #1 (05/07/18)
Green and red lamps OFF. Adjust clearance by removing shim from is hard to start. Impeller and volute binding? behind impeller. Defective engine? See Engine Owner's Manual. PAGE 32 — QP3Ti TRASH PUMP • OPERATION AND PARTS MANUAL — REV. #1 (05/07/18)
Page 33
NOTES QP3Ti TRASH PUMP • OPERATION AND PARTS MANUAL —REV. #1 (05/07/18) — PAGE 33...
EXT (+) EXT (-) FS (+) FS (-) ORANGE YELLOW BLUE SKY BLUE GREEN LIGHT GREEN PINK WHITE GRAY VIOLET BEIGE COLOR COMBO : GROUND/MARKING PAGE 34 — QP3Ti TRASH PUMP • OPERATION AND PARTS MANUAL — REV. #1 (05/07/18)
IV ) Red light Flashing 3 times, turns OFF for 3 seconds and repeats Check electrical connections. V ) Red light Flashing 5 times, turns OFF for 3 seconds and repeats ECU error. Contact Multiquip for service. QP3Ti TRASH PUMP • OPERATION AND PARTS MANUAL —REV. #1 (05/07/18) — PAGE 35...
“Remarks” Column. assembly/kit that can be purchased, or is not available for sale through Multiquip. PAGE 36 — QP3Ti TRASH PUMP • OPERATION AND PARTS MANUAL — REV. #1 (05/07/18)
2....1992108050 ..CAP 1....9820043000 ..FUSE, MINI 30A NOTICE Part numbers on this Suggested Spare Parts list may supersede/replace the part numbers shown in the following parts lists. QP3Ti TRASH PUMP • OPERATION AND PARTS MANUAL —REV. #1 (05/07/18) — PAGE 37...
DECAL, CAUTION, HOT MUFFLER DECAL, DO NOT RUN PUMP DRY SERIAL PLATE ............1....CONTACT MQ PARTS DEPT. DECAL, WARNING, FLAMMABLE DECAL, WARNING, START FIRES DECAL, MQ LOGO/STRIPE QP3Ti TRASH PUMP • OPERATION AND PARTS MANUAL —REV. #1 (05/07/18) — PAGE 39...
PUMP ASSEMBLY MECHANICAL SEAL & O-RINGS 27-1 PAGE 40 — QP3Ti TRASH PUMP • OPERATION AND PARTS MANUAL — REV. #1 (05/07/18)
Page 41
When ordered as part of the kit, quantity of -ring is one. Replacement Impeller requires two O-rings, so it is necessary to order one additional O-ring. QP3Ti TRASH PUMP • OPERATION AND PARTS MANUAL —REV. #1 (05/07/18) — PAGE 41...
Page 42
PUMP ASSEMBLY (CONTINUED) MECHANICAL SEAL & O-RINGS 27-1 PAGE 42 — QP3Ti TRASH PUMP • OPERATION AND PARTS MANUAL — REV. #1 (05/07/18)
INCLUDED WITH PILOT LAMPS ITEMS 32 AND 33. INCLUDED WITH DRAIN/FILL SWITCH ITEM 20. INCLUDED WITH FLOW CONTROL POTENTIOMETER ITEM 19. WIRE HARNESS INCLUDED WITH CONTROL PANEL. PAGE 44 — QP3Ti TRASH PUMP • OPERATION AND PARTS MANUAL — REV. #1 (05/07/18)
HOUR METER 7308662910 KNOB ROCKER SWITCH, AUTO/STANDBY PILOT LAMP RED PILOT LAMP GREEN WIRE HARNESS 36#. 0143090510 TRUSS HEAD SCREW 3TIOPTCOPN CONTROL PANEL ASSY........1....INCLUDES ITEMS W/# QP3Ti TRASH PUMP • OPERATION AND PARTS MANUAL —REV. #1 (05/07/18) — PAGE 45...
FRAME AND BATTERY ASSEMBLY 28 29 NOTES: INCLUDED WITH HINGE PIN ITEM# 9. INCLUDED WITH U-BOLT ITEM 16. USE WITH PUMP END ONLY. PAGE 48 — QP3Ti TRASH PUMP • OPERATION AND PARTS MANUAL — REV. #1 (05/07/18)
Need help?
Do you have a question about the QP3Ti and is the answer not in the manual?
Questions and answers