WARNINGS
Risk of electrical shock
ALL ELECTRICAL CONNECTIONS MUST BE PERFORMED BY A LICENSED ELECTRICIAN AND
MUST CONFORM TO ALL NATIONAL, STATE AND LOCAL ELECTRICAL CODES IN EFFECT AT
THE TIME OF INSTALLATION INCLUDING ENSURING PARTS ARE INSTALLED IN THE
CORRECT ZONE AND EQUIPOTENTIAL BONDING IS CARRIED OUT IF REQUIRED.
The appliance should be supplied through a residual current device (RCD) having a rated
residual operating current not exceeding 30mA.
The appliance must be connected to a suitable rated and weather protected power supply. The
supply line should be a dedicated power circuit and means for disconnection must be incorporated in
the fixed wiring in accordance with your local wiring regulations. Means for disconnection from the
supply mains should have a contact separation in all poles that provide full disconnection under over
voltage Category III conditions.
Earthed appliances must be permanently connected to fixed wiring.
The appliance contains no serviceable parts. Do not attempt service of this control pack. Contact
your dealer or authorised service agent for assistance.
Turn the mains power OFF before servicing appliance or modifying any cable connection.
Suitable for indoor use only or when installed under a weatherproof spa skirt. The appliance should
be installed in an enclosure such that all electrical connections cannot be accessible to the user
without the use of a tool.
Low voltage or improper wiring may cause damage to this appliance. Read and follow all wiring
instructions when connecting to power supply.
If the supply cord is damaged it must be replaced by the manufacturer, its service agent, licensed
electrician or similarly qualified persons in order to avoid a hazard.
To prevent electric shock hazard and/or water damage to this appliance, all unused receptacles
must have a water proof seal in place.
Parts incorporating electrical components must be located or fixed so that they cannot fall into the
bath or spa.
Parts containing live parts, except parts supplied with safety extra-low voltage not exceeding 12V
must be inaccessible to a person in the bath or spa.
This appliance must NOT be installed in proximity to highly flammable materials.
Water temperature in excess of 38
It is the spa manufacturer's and/or installer's responsibility to select suitable loads and configure
load shed settings (if required) to ensure the system does not exceed its rated maximum total load.
It is the installer's responsibility to ensure the floor can support the expected load of the bath or spa
and an adequate drainage system has to be provided to deal with overflow water.
A whirlpool spa should incorporate a water filtration system where the required level of water purity
can be achieved.
An adequate drainage system must be provided if the equipment is to be installed in a pit.
This appliance is not intended for use by persons (including children) with reduced physical, sensory
or mental capabilities, or lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
V.2005
C may cause hyperthermia (heat stress).
o
Page | 1

Advertisement

loading
Need help?

Need help?

Do you have a question about the Mini 1 and is the answer not in the manual?

Questions and answers

Summary of Contents for SpaNet Mini 1

  • Page 1 WARNINGS Risk of electrical shock ALL ELECTRICAL CONNECTIONS MUST BE PERFORMED BY A LICENSED ELECTRICIAN AND • MUST CONFORM TO ALL NATIONAL, STATE AND LOCAL ELECTRICAL CODES IN EFFECT AT THE TIME OF INSTALLATION INCLUDING ENSURING PARTS ARE INSTALLED IN THE CORRECT ZONE AND EQUIPOTENTIAL BONDING IS CARRIED OUT IF REQUIRED.
  • Page 2: Electrical Installation

    Load Shedding” section on page 18 of this manual for further information. Electrical Specifications Model Max Current Input Voltage Phases Heater Size Mini 1 / Mini 2 230-240V AC 50/60 1.5kW / 2.0kW / 3.0kW Wiring Diagram (Mini 1) Output Ratings Model...
  • Page 3: Dip Switches

    Wiring Diagram (Mini 2) Output Ratings Model Outlet Max Current Output Voltage Typical Accessory SV Mini 2 230V 230-240V AC 50/60 Heat Pump / Stereo Pump 1 230-240V AC 50/60 Circ / 2-spd or 1-spd Pump Pump 2 230-240V AC 50/60 1-spd Pump 03/UV...
  • Page 4 SPA PACK INSTALLATION Floor Mounting Procedure The controller should be mounted vertically in a fixed position Select a suitable location on the spa base and firmly secure spa pack using four (4) x screws of appropriate length backed with flat washers. Each screw should be positioned in the moulded cut outs of the mounting feet (refer aside).
  • Page 5: Heater Installation

    HEATERS INSTALLED IN AN INCORRECT ORIENTATION WILL NOT BE COVERED BY THE SPANET PRODUCT WARRANTY. The heater can be plumbed on either suction or discharge lines however water should flow from the spa over the heater sensors first, then returning the heated water to the spa.
  • Page 6 PCB. PRODUCT FAILURES AS A RESULT OF POOR CONNECTION AT THE HEATER TERMINAL BLOCK WILL NOT BE COVERED BY THE SPANET PRODUCT WARRANTY. IMPORTANT NOTE Ensure heater wires are connected to the terminal block correctly and confirm that terminal screws are tight and secure.
  • Page 7 Contact Us Spa Net Pty Ltd Unit 1 103 Mulgrave Road Mulgrave NSW 2756 Australia Phone: +61 2 4587 7766 Fax: +61 2 4587 8766 www.spanet.com.au Technical Support & Service service@spanet.com.au Accounts Department accounts@spanet.com.au Sales Department sales@spanet.com.au V.2005 Page | 7...

This manual is also suitable for:

Mini 2Sv mini 1Sv mini 2