INTRODUCTION

The MLR2000 is a Multi-Line, Multi-Format Digital Receiver for
commercial fire and burglary. The base unit consists of up to 60
individual line-cards (DRL-2000) connected to a dual redundant
central resource, router and protocol converter (CPM-2000). The
MLR2000 includes many features, especially high bandwidth
internal buses and high bandwidth external connections to allow
traditional network philosophies to be observed for the first time
on a central station receiver. The MLR2000 can decode a variety
of popular and widely used communication formats. Refer to
Appendix D, DRL2000 Communication Formats for a list of the
available communication protocols.
The MLR2000's real-time clock and calendar 'stamps' all information
received with the time and date, and all information may be
printed or forwarded to a computer. To ensure security,
adjustment of the clock, calendar and other programming is
protected by password codes.

CPM2000

The CPM2000 Central Processing Module oversees operation
of the receivers. Along with its built-in keypad and LCD message
screen, the CPM2000 features TCP/IP, two parallel printers, one
serial printer and two serial computer interface capability.

DRL2000

Each DRL2000 Line Card Module can monitor one telephone
line. The Line Card module is equipped with a 256-event nonvolatile
memory to record events and corresponding telephone numbers.
Calling source (caller ID and calling name) capability is built-in
and telephone numbers can be printed out, sent to automation
and stored in memory. Events and information stored in memory
may be printed at any time. Each line card also features flash
downloads through Ethernet or serial output for fast software
upgrades.

Power and Supervision

PSU 2000
PSU 2000
PSU 2000
PSU 2000
PSU 2000
The MLR2000 power supplies inputs are 120 V
Hz. Each AC power supply supplies a nominal 28 V
power. The receiver is equipped with 24V rechargeable stand-
by battery connections at 160 Ahr. and an automatic battery
charger. Provision is made for an internal battery pack for
temporary use. User supplied batteries may be used externally
but must be fused and connected to 10-32 lugs supplied via
a stud termination.
Full power operation is .5 Amps per line and 1 Amp per CPM at
28 V
nominal. All elements have extensive power down capabilities
DC
and are implemented in CMOS logic.
Supervision
Supervision
Supervision
Supervision
Supervision
The stand-by battery voltage and connections are supervised.
The Line Cards are also continuously supervised to ensure
uninterrupted communication with the CPM2000. Any trouble
conditions are reported on the LCD screens and sent to the
printer and the computer.
The DRL2000 Line Card Module also verifies communications
with the CPM2000. In the event of a malfunction, the operator
will be advised with a visual indication and the Line Cards will
continue to function. Each line card will continue to receive
information.
The printer is supervised for off-line, paper out and other trouble
conditions. The communication link to the computer through
the RS232 ports is monitored by the supervisory 'heartbeat'
test transmissions.
AC
Compatibility
Compatibility
Compatibility
Compatibility
Compatibility
Central station automation software packages such as:
• MAS
• SIS
support the MLR2000 Sur-Gard interface.
Refer to automation software specifications for compatibility.
NOTES: Automation connections are considered supplemen-
NOTES: Automation connections are considered supplemen-
NOTES: Automation connections are considered supplemen-
NOTES: Automation connections are considered supplemen-
NOTES: Automation connections are considered supplemen-
tary per UL864 Listing. Compatibility with the automation
tary per UL864 Listing. Compatibility with the automation
tary per UL864 Listing. Compatibility with the automation
tary per UL864 Listing. Compatibility with the automation
tary per UL864 Listing. Compatibility with the automation
software in a system used at a central station is intended
software in a system used at a central station is intended
software in a system used at a central station is intended
software in a system used at a central station is intended
software in a system used at a central station is intended
to be handled under a separate UL1981 software and/or
to be handled under a separate UL1981 software and/or
to be handled under a separate UL1981 software and/or
to be handled under a separate UL1981 software and/or
to be handled under a separate UL1981 software and/or
site certification evaluation.
site certification evaluation.
site certification evaluation.
site certification evaluation.
site certification evaluation.

CPM2000 Outputs/ Inputs

The CPM2000 features four switched-negative (PGMOUT1 is
activated when automation fails) outputs, two relay outputs
and four inputs.

System Overview

• Patented Caller Identification (Call Display) capability
• Patent Pending DNIS and ANI Identification
• Nonvolatile RAM on each DRL2000 line card module for
programming and event buffer.
• Fast Ethernet communication between line-cards and CPM
• Flash download for software upgrades
• DSP
• Up to 64 different options set (profiles per line)
• Patent pending virtual configurations
• 3/1, 4/2 formats with or without parity, 4/1 without parity
at 10, 14, 20, or 40 baud
• 4/1, 4/2, 4/3, and 4/3 DTMF formats
• Optional* formats: 3-2, 4/1, 4/2 extended
• ACRON DTMF format
• Contact ID (DTMF) format
• Adcor 20 baud
at 10A, 60
• Super fast or high speed DTMF format, with or without parity
+/-5%
DC
• DTMF 4/1 express format (optional)
• DTMF 4/2 express format
• FBI super fast format with or without parity
• Radionics Modem II, Modem IIE, Modem IIIa
• SIA format: 110 and 300 baud, tone and data
acknowledgement
• SK FSK1, FSK2
• Any handshake frequencies by increment of 100 Hz from
100 Hz to 2300 HZ, Dual Tone, SIA FSK, Modem II and ITI
selected by configuration commands
• Up to 8 different handshakes per profile.
• Large, easy to read 2-line, 16-characters-per-line, LCD (Liquid
Crystal Display) screen
• All modules function individually to help ensure uninterrupted
operation during hardware or software upgrades
• Inputs on CPM2000 for UPS supervisory
• 255 lines maximum per receiver
• 256-event memory buffer on each individual line card
• Real-time clock
• CPM2000 features 32-bit micro-controller
• Two parallel printer port; three serial RS232 ports and 10
Base T connection.
• Programmable serial ports configuration
1
• DICE
• SIMS II
• ABM
• MICRO KEY
• GENESYS
2
and BFSK formats

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SG SECURITY COMMUNICATIONS MLR-2000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Sur-Gard SG SECURITY COMMUNICATIONS MLR-2000

  • Page 1: Introduction

    • ABM • MICRO KEY MLR2000 includes many features, especially high bandwidth support the MLR2000 Sur-Gard interface. internal buses and high bandwidth external connections to allow Refer to automation software specifications for compatibility. traditional network philosophies to be observed for the first time...
  • Page 2: Virtual Receiver Architecture

    All device status and with redundant CPM's the B unit will take up where the information is in Sur-Gard format. The reporting of status on A unit failed with a loss of no more than 30 seconds. External...
  • Page 3: Quick Start

    ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ QUICK START Receiver Setup and Operation • Take a 50-ohm coaxial cable and connect one end to the BNC connector (ETHERNET B) of the CPM2000.
  • Page 4 72 Line Cards Configuration (Expansion Cabinet) 72 Line Cards Configuration (Expansion Cabinet) 72 Line Cards Configuration (Expansion Cabinet) 72 Line Cards Configuration (Expansion Cabinet) 72 Line Cards Configuration (Expansion Cabinet) ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○...
  • Page 5 Power Cable Connections Power Cable Connections Power Cable Connections Power Cable Connections Power Cable Connections • Take the power cables (10 gage) and connect one end to • Take the power cable for the CPM2000 and connect the the power terminals of the backplane marked PWR-GND (black labelled wire to the designated terminal on the backplane.
  • Page 6 72 Line Cards Configuration (Expansion Cabinet) 72 Line Cards Configuration (Expansion Cabinet) 72 Line Cards Configuration (Expansion Cabinet) 72 Line Cards Configuration (Expansion Cabinet) 72 Line Cards Configuration (Expansion Cabinet) ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○...
  • Page 7 Signaling/Supervisory Connections 60 Line Cards Configuration 60 Line Cards Configuration 60 Line Cards Configuration 60 Line Cards Configuration 60 Line Cards Configuration ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○...
  • Page 8 72 Line Cards Configuration (Expansion Cabinet) 72 Line Cards Configuration (Expansion Cabinet) 72 Line Cards Configuration (Expansion Cabinet) 72 Line Cards Configuration (Expansion Cabinet) 72 Line Cards Configuration (Expansion Cabinet) ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○...
  • Page 9: Bench Testing

    'DRL2000 Library Decoding and Event Codes Table' will 2. Point and click at 'Transfer' on the Hyper Terminal menu and be used with the Sur-Gard automation communication protocol access the 'Send File' category. The 'Send File' window should to send signals to the computer, if connected.
  • Page 10: Installation

    Printer Connections The maximum battery charging current is factory set at 5A. The following UL Listed printers can be used with the MLR2000: Sur-Gard CPU-1150 (Panasonic KX-P1150) Removing and Installing System Components DMP SCS-PTR (Okidata Microline 182/184) Note that the receiver does not have to be powered down Connect the parallel printers to the MLR2000 printer output when components are removed or installed.
  • Page 11: Drl2000 Digital Receiver Line Card

    ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ DRL2000 DIGITAL RECEIVER LINE CARD The DRL2000 acts as an interface between the digital alarm DRL2000 Controls transmitter and the CPM2000.
  • Page 12: Drl2000 Operating Mode

    Printer: 19-Nov-1998 10:40:56 - Nov 19 1998-11:32:25- retained in the DRL2000 event buffer. When the event buffer F3/00-SG -19-069-123F—SUR-GARD SECURT is full, the line card will stop answering the calls. When the CPM2000 Error condition is corrected, the alarm messages in the event buffer will be transmitted to the CPM2000 with the corresponding time/ date the alarm have been received.
  • Page 13: Profiles Introduction

    ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○...
  • Page 14 above occur Option [0F] to [10]: Reserved Option [0F] to [10]: Reserved Option [0F] to [10]: Reserved Option [0F] to [10]: Reserved Option [0F] to [10]: Reserved 02 Same as set to 00 when used with the Call Centre Feature Option [11]: Hookflash Enable/Disable Option [11]: Hookflash Enable/Disable Option [11]: Hookflash Enable/Disable...
  • Page 15: Options [30] - [Ff]: Dynamic Options

    Options [30] - [3F]: 3/1 - 4/1 Digit 0-F Options [30] - [3F]: 3/1 - 4/1 Digit 0-F 10 DUCT The DRL2000 uses a unique Sur-Gard communication format to 11 FLAME transmit data through the CPM2000 to the central station computer.
  • Page 16 46 FIRE SUPERVISORY LOSS OF CENTRAL POLLING 47 LOW WATER PRESSURE USER TX USWR 48 LOW CO2 80 LOW RECEIVED SIGNAL STRENGTH 49 GATE VALVE SENSOR 4A LOW WATER LEVEL 82 PROTECTION LOOP 4B PUMP ACTIVATED 83 PROTECTION LOOP OPEN 4C PUMP FAILURE 84 PROTECTION LOOP SHORT 4D ENVIRONMENTAL...
  • Page 17 D9 RESERVED other brand receivers to the Sur-Gard receiver. DA RESERVED NOTE: Option [70] is ignored when using SIA, ITI, Contact- NOTE: Option [70] is ignored when using SIA, ITI, Contact-...
  • Page 18 account codes between 300 and 6FF to activate the 2-Way Audio Option [76]: Accounts 3/x to 4/x Option [76]: Accounts 3/x to 4/x Option [76]: Accounts 3/x to 4/x Option [76]: Accounts 3/x to 4/x Option [76]: Accounts 3/x to 4/x function, program Option [7B] as '36'.
  • Page 19 Bit 0 3 Digit pulse formats. Option [8F] : Handshake #7 duration Option [8F] : Handshake #7 duration Option [8F] : Handshake #7 duration Option [8F] : Handshake #7 duration Option [8F] : Handshake #7 duration Bit 1 4 Digit pulse formats. Option [90]: Handshake #8 duration Option [90]: Handshake #8 duration Option [90]: Handshake #8 duration...
  • Page 20 02 and 03 if the SIA protocol is desired. settings 02 and 03 if the SIA protocol is desired. The Sur-Gard 4/3 DTMF format is made up of a 4-digit account code, a 1-digit event code, and a 2-digit hexadecimal zone code...
  • Page 21 Where = Receiver Number Option [9F]: Ademco High Speed RS232 Option [9F]: Ademco High Speed RS232 Option [9F]: Ademco High Speed RS232 Option [9F]: Ademco High Speed RS232 Option [9F]: Ademco High Speed RS232 When this option is programmed as '00', the DRL2000 will = Line Number convert the High Speed format signal into 4/2 format (Ex: = Space...
  • Page 22: Dnis/Caller Id Implementation

    DNIS/Caller ID Implementation DNIS Number DNIS Number Ten digit data Ten digit data Profile Profile DNIS Number DNIS Number DNIS Number Ten digit data Ten digit data Ten digit data Profile Profile Profile The proposition of DNIS input in the number field of NACID 0000 0000000000 (North American Caller ID) is required for the implementation of...
  • Page 23: Drl2000 Communication Formats Common Formats

    Sur-Gard DTMF Formats Sur-Gard DTMF Formats Sur-Gard DTMF Formats 120 Panic alarm Sur-Gard DTMF 4/3 and 4/3 with Checksum formats provide 121 Duress fast, reliable and easy to understand and decode data transmission. 122 Silent On-line time will be greatly reduced when using 4/3 and 4/3 123 Audible with Checksum formats.
  • Page 24 159 Low temp 355 Loss of radio supervision 457 exit Error 161 Loss of air flow 356 Loss of central polling 458 User on Premises Fire supervisory - 200 and 210 Fire supervisory - 200 and 210 Fire supervisory - 200 and 210 357 Radio Xmtr VSWR 459 Recent Close Fire supervisory - 200 and 210...
  • Page 25 The DRL2000 will decode the signal as regular 4/ 1 or 4/2 format. Option [99] must be programmed as '01' to FBI RS232 Option On decode the 4/1 Express format instead of the Sur-Gard 4/3 with Computer: JO1123 23452032 [14] Checksum format.
  • Page 26 For Alarm For Alarm Corresponding Event Corresponding Event For Alarm For Alarm For Alarm Corresponding Event Corresponding Event Corresponding Event Modem II RS232 option OFF Message Code Message Code Message Code Message Code Message Code Code (Options 30-3F) Code (Options 30-3F) Code (Options 30-3F) Code (Options 30-3F) Code (Options 30-3F)
  • Page 27: Sg-Cpm2000 Central Processing Module

    ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ SG-CPM2000 CENTRAL PROCESSING MODULE CPM2000 Controls The CPM2000 is the central processing module that monitors the DRL2000 Line Cards and forwards the information from the •...
  • Page 28: Cpm2000 Wiring Diagram

    The Manual Restore rule is a command that may be issued on It is estimated that sockets may appear and disappear regularly the Sur-Gard console to jump back to the first entry. as processes are terminated and reconstituted. After 5 seconds The CPM and automation must connect to all resources announced of loss the CPM2000 shifts to the next connection level.
  • Page 29: Mlr2000 Computer Interface

    To setup this mode a menu will prompt the user for an IP read () Address. Once the IP address is set up all other options and setups may be done via the Sur-Gard Console Package running on a Windows 95/98/NT platform. Status Addressing TCP/IP Ports Line card status will be reported via physical addressing.
  • Page 30: Console Specifies Which Sg Automation To Supervise

    CPM2000 Internal Status Messages: CPM2000 Internal Status Messages: CPM2000 Internal Status Messages: CPM2000 Internal Status Messages: CPM2000 Internal Status Messages: Description Description Printer Message Printer Message Automation message Automation message Description Description Description Printer Message Printer Message Printer Message Automation message Automation message Automation message 12V Battery Low...
  • Page 31: Psu2000 Power Supply Module

    ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○...
  • Page 32: Automation Protocols

    ○ ○ ○ AUTOMATION PROTOCOLS DETAILED DESCRIPTION OF COM OUTPUTS The Sur-Gard SG-MLR2000 receiver sends a variety of protocols to report signals to the central station computer via a TCP/IP or COM Responses COM Responses COM Responses COM Responses COM Responses an RS232 port.
  • Page 33: Appendix A: Drl2000 Communication Formats

    Silent Knight Fast 1400 Hz 1900 Hz 14 bps 4/2,4/1,3/1 1400 Hz Silent Knight FSK1 1400 Hz 1400 Hz Silent Knight FSK2 1400 Hz 1400 Hz Sur-Gard 2300 Hz DTMF DTMF 2300 Hz Sur-Gard 2300 Hz DTMF DTMF 4/3+Checksum 2300 Hz Sur-Gard...
  • Page 34: Decimal - Hex - Binary Conversion Chart

    ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○...
  • Page 35: Appendix C: Ascii Character Chart

    BINARY BINARY BINARY BINARY BINARY BINARY BINARY BINARY BINARY BINARY ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ APPENDIX C: ASCII 1110 1010 1010 1110 1010 1111 1110 1011 CHARACTER CHART 1011 0000...
  • Page 36 Limited Warranty Sur-Gard Ltd. warrants that for a period of ninety days from the date of purchase, the product shall be free of defects in materials and workmanship under normal use and that in fulfillment of any breach of such warranty, Sur-Gard Ltd. shall, at its option, repair or replace the defective equipment upon return of the equipment to its repair depot.
  • Page 37 Industry Canada NOTICE Notice: Notice: Notice: Notice: The Industry Canada label identifies certified equipment. This Notice: AVIS: AVIS: L'étiquette de l'Industrie Canada identifie le matériel homologué. AVIS: AVIS: AVIS: certification means that the equipment meets certain telecommunications Cette étiquette certifie que le matériel est conforme à certaines network protective, operational and safety requirements.
  • Page 38 © 1999 SG Security Communications 401 Magnetic Drive, Units 24-28 Downsview, Ontario Canada M3J 3H9 (416) 665-4494 (416) 665-4222 29003029 R002 1-800-418-7618 Printed in Canada www.sur-gard.com...
  • Page 39 ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○...
  • Page 40: Table Of Contents

    ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○...

Table of Contents