• RIGOL products are covered by P.R.C. and foreign patents, issued and pending. • RIGOL reserves the right to modify or change parts of or all the specifications and pricing policies at the company's sole decision. • Information in this publication replaces all previously released materials.
Page 18
Do Not Operate With Suspected Failures. If you suspect that any damage may occur to the instrument, have it inspected by RIGOL authorized personnel before further operations. Any maintenance, adjustment or replacement especially to circuits or accessories must be performed by RIGOL authorized personnel.
MSO8000 Series Overview MSO8000 series is a medium and high-end mixed signal digital oscilloscope designed based on UltraVision II platform built on RIGOL's custom ASIC technology. Integrating 7 independent instruments into one, the oscilloscope is equipped with the analog bandwidth of up to 2 GHz, extremely high memory depth of 500 Mpts, sound waveform display effects, excellent waveform capture rate, and powerful data analysis functions.
This manual gives you a quick review about the front and rear panel of MSO8000 series, the user interface, and the basic operation method. http:// For the latest version of this manual, download it from the official website of RIGOL ( www.rigol.com Publication Number...
The consigner or carrier shall be liable for the damage to the instrument resulting from shipment. RIGOL would not be responsible for free maintenance/rework or replacement of the instrument. 2. Inspect the instrument In case of any mechanical damage, missing parts, or failure in passing the electrical and mechanical tests, contact your RIGOL sales representative.
4.3.5 To Connect the Probe RIGOL provides the passive probe, the active probe, and the logic probe for the MSO8000 Datasheet . For MSO8000 series. For specific probe models, please refer to detailed technical information of the probes, please refer to the corresponding Probe User Guide.
Figure 4.9 2. Connect the other terminal of the logic probe to the signal terminal under test. RIGOL's MSO8000 series has a standard configuration of a logic probe RPL2316. To apply to different application scenarios, RPL2316 provides three connection RPL2316 Logic Probe methods to connect the signal under test.
Page 40
3. Press Online upgrade or enable the touch screen to tap "Online upgrade", then a "System Update Information" window is displayed, requesting you whether to accept or cancel "RIGOL TERMS OF ONLINE UPGRADE SERVICE". Tap "Accept" to start online upgrade. Tap "Cancel" to cancel the online upgrade.
Page 61
Then, you can install the option according to the following steps. a. Obtain an option license www.rigol.com a. Log in to the RIGOL official website ( ), click SERVICE CENTRE (Products & Services) > License Activation to enter the license activation interface.
5.10.1 Passive Probe If a passive probe is connected, for example, when RIGOL RP3500A probe model is connected to the oscilloscope, press Probe to open the probe menu. Its sub-menus are grayed out and disabled.
To Set the Vertical System 5.10.2 Active Probe If an active probe is connected, for example, when RIGOL RP7150 probe model is connected to the oscilloscope, press Probe to open the probe menu, then operate on the menu item. •...
In the trigger debugging process of video signals, the frequency in different part of the signal can be reflected by a different brightness, as RIGOL digital oscilloscope provides the intensity graded color display function. Experienced users can quickly judge the signal quality and discover abnormalities during the debugging process.
Binary Header Format 1. File Header There is only one file header in a binary file. The file header contains the following information. Two-byte characters, RG, indicating that the file is the RIGOL Cookie binary data file format. Version Two-byte, indicating the file version.
Remote Interface Configuration MSO8000 series can communicate with the PC via the USB, LAN, or GPIB (requiring to work with RIGOL's USB-GPIB adaptor) interface. Before using the remote interfaces, configure the corresponding interface according to the introductions in the following section.
RIGOL official website ( ). If yes, a red spot appears at the upper-left corner of the Online upgrade menu, prompting you that the latest upgrade version is available and you can perform online upgrade.
System Utility Function Setting - If you select "Text" under Screen Saver, press Text, and then the filename input interface is displayed. Input the filename, for example, "RIGOL Scope". For details, refer to descriptions in " To Create a Folder ".
At this time, you can pinch or stretch the icons on RIGOL to zoom out or zoom in icons to check whether the gestures work normally. Press three consecutive times to exit the touch test interface.
PC via the USB interface. You can also click USB-TMC to search for the resource. 3. View the device resource The resources found will appear under the "RIGOL Online Resource" directory, and the model number and USB interface information of the instrument will also be displayed.
4. View the device resource The resources found will appear under the "RIGOL Online Resource" directory. 5. Control the instrument remotely Right-click the device resource name and select "SCPI Panel Control" to open the remotely command control panel.
5. View the device resource Click OK to go back to the main interface of Ultra Sigma. The searched instrument resource will be displayed under the directory of "RIGOL Online Resource". 6. Control the instrument remotely Right-click the device resource name. In the displayed menu, select "SCPI Panel Control"...
Phase Deviation Correction Jig) Real-time Eye Diagram and Jitter Analysis MSO8000-JITTER NOTE For all the accessories and options, please contact the local office of RIGOL. 26.2 Appendix B: Warranty RIGOL TECHNOLOGIES CO., LTD. (hereinafter referred to as RIGOL) warrants that the product mainframe and product accessories will be free from defects in materials and workmanship within the warranty period.
Need help?
Do you have a question about the MSO8000-BND and is the answer not in the manual?
Questions and answers