Summary of Contents for Wood Stone Traditional Series
Page 1
Installation and Operation Manual TRADITIONAL SERIES Stone Hearth Oven Gas-Fired, Gas/Wood Combination Models TRADITIONAL SERIES WS-TS-5-(RFG)-(IR)-(W) TRADITIONAL SERIES WS-TS-6-(RFG)-(IR)-(W) WOOD STONE CORPORATION Toll Free 800.988.8103 1801 W. Bakerview Rd. Tel 360.650.1111 Bellingham, WA 98226 USA Fax 360.650.1166 www.woodstone-corp.com DOC NO M0119.12...
Gas-Fired & Gas/Wood Traditional Series Installation and Operation Manual TABLE OF CONTENTS This manual covers all configurations of the Traditional Series Oven: Gas-Fired and Wood/Gas Combination models. Make certain you read the appropriate section for your model. Blocks indicate sections relevant to your model...
TRADITIONAL SERIES OVEN Gas-Fired & Gas/Wood Traditional Series Installation and Operation Manual INSTALLATION AND OPERATION MANUAL THE WOOD STONE TRADITIONAL SERIES STONE HEARTH COOKING EQUIPMENT WS-TS-(5,6)-RFG-(W) WS-TS-(5,6)-RFG-IR-(W) WS-TS-(5,6)-W-IR GAS-FIRED & GAS/WOOD COMBINATION MODELS ADDITIONAL COPIES AVAILABLE UPON REQUEST Shown: TS-5-RFG-IR info@woodstone-corp.com...
CAUTIONS & WARNINGS Gas-Fired & Gas/Wood Traditional Series Installation and Operation Manual WOOD STONE TRADITIONAL SERIES GAS-FIRED AND GAS/WOOD COMBINATION OVEN INSTALLATION AND OPERATING INSTRUCTIONS RETAIN THIS MANUAL FOR FUTURE REFERENCE Additional copies of this manual at woodstone-corp.com. For prompt responses to service/maintenance questions, call us at @ 1-800-988-8103.
Page 5
CAUTIONS & WARNINGS Gas-Fired & Gas/Wood Traditional Series Installation and Operation Manual A MAJOR CAUSE OF OVEN RELATED FIRES IS A FAILURE TO MAINTAIN REQUIRED CLEARANCES TO COMBUSTIBLE MATERIAL. IT IS OF UTMOST IMPORTANCE THAT THIS OVEN BE INSTALLED ONLY IN ACCORDANCE WITH THESE INSTRUCTIONS.
188,000 BTU, NG (RFG-IR) 120VAC, 4A Bellingham, WA 98226 USA 360.650.1166 UT THE WRITTEN PERMISSION OF WOOD STONE IS require us to change specifications without notice. NFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF WOOD STONE CORPORATION 159,000 BTU, LP (RFG-IR)
THE INFORMATION CONTAINED IN THIS DRAWING IS THE THE INFORMATION CONTAINED IN THIS DRAWING IS THE An ongoing program of product improvement may 188,000 BTU, NG (RFG-IR) WITHOUT THE WRITTEN PERMISSION OF WOOD STONE IS Bellingham, WA 98226 USA 159,000 BTU, LP (RFG-IR) 360.650.1166...
The customer will receive an Oven Shipping Notification when the oven leaves the Wood Stone factory. This will include a PRO# and a trucking company contact number. Wood Stone recommends that you confirm the delivery date/time with the trucking company before committing to heavy equipment and/or labor. Our goal is a smooth and safe delivery.
Installation and Operation Manual CLEARANCES 1. The Wood Stone Traditional Series oven must have a minimum 1-inch clearance to combustibles from all sides, and 6-inch clearance to combustibles from the top. If building materials will contact the oven, they must be completely non-combustible.
Page 10
INSTALLATION CLEARANCES Gas-Fired & Gas/Wood Traditional Series Installation and Operation Manual THE FOLLOWING CLEARANCE INFORMATION APPLIES TO ALL WOOD STONE TRADITIONAL SERIES OVENS 6" 6" top clearance to combustible building materials. If enclosing the oven, any facade materials 6" to either side of the doorway and above must be NON-COMBUSTIBLE.
We recommend 1/2" or smaller tiles applied over a suitable non-combustible skim coat. Smaller tiles can more easily conform to the curved shape of the oven. Because of the unique shape of the Traditional Series oven, we recommend employing a skilled tile contractor.
DO NOT USE FLAME TO TEST FOR LEAKS. Wood Stone recommends that the oven’s individual shutoff valve (supplied by others) be left readily accessible. Wood Stone also recommends that inspection and maintenance of the burner and gas piping connections of this appliance be performed at regularly scheduled intervals and only by professional gas appliance service agencies.
Page 13
GAS SPECIFICATIONS Gas-Fired & Gas/Wood Traditional Series Installation and Operation Manual MAXIMUM HOURLY BTU INPUT RATES FOR WS-TS MODELS Burner Configuration (NG) Model RFG-IR-W, RFG-IR RFG, RFG-W W-IR WS-TS-5-NG 188,000 105,000 83,000 188,000 105,000 83,000 WS-TS-6- NG Burner Configuration (LP)
ELECTRICAL SPECIFICATIONS Gas-Fired & Gas/Wood Traditional Series Installation and Operation Manual Incoming power should be connected to the terminal strip located in the transformer junction box beneath the oven (see diagram below). The standard oven model comes configured for connection to a 120 VAC circuit. The oven can be ordered configured for connection to a 240 VAC circuit.
The following are the manufacturer’s recommendations for venting the Wood Stone Traditional Series ovens. It is never appropriate to use “B vent” in any part of an exhaust system connected to a Wood Stone oven. All duct material must be manufactured to the specifications of a grease duct.
Page 16
Solid fuel burning ovens must be vented separately from non-solid fuel burning equipment. It is never appropriate to use “B vent” in any part of an exhaust system connected to a Wood Stone oven. All duct material must be manufactured to the specifications of a grease duct. Due to the possibility of sparks entering the duct, exhaust systems serving solid fuel equipment MUST not be combined with exhaust systems serving other (non-solid fuel) equipment.
FRONT PANEL ASSEMBLY Gas-Fired & Gas/Wood Traditional Series Installation and Operation Manual STANDARD FRONT PANEL AND TOE KICK ASSEMBLY INSTRUCTIONS Flame Height Control Knob Controller Service Panel Transformer Box Contains terminal strip for incoming power supply. NOTE: Have licensed electrician make this electrical connection.
GAS CONTROLLERS Gas-Fired & Gas/Wood Traditional Series Installation and Operation Manual CONTROLLER FUNCTIONS TYPE 2 RFG-IR-(W) AND W-IR MODELS Hearth Heat indicator light Dome Flame indicator light Indicates that the pilot for the Indicates the pilot for the Power indicator light Underfloor IR burner is lit.
FLAME HEIGHT CONTROL Gas-Fired & Gas/Wood Traditional Series Installation and Operation Manual DETERMINING THE APPROPRIATE FLAME HEIGHT For each specific configuration of oven there is a system that determines what the desired flame height will be. Each flame height corresponds to a saturated floor temperature. Several factors need to be accounted for in order to determine this relationship for each oven.
THERMAL CLEANING If a Wood Stone gas-fired oven is operated at low temperatures (below 450 °F), it is possible that grease from food could condense on the walls and ceiling of the oven. To remove the grease that has accumulated on the walls and ceiling of the oven, simply turn the radiant flame to its highest setting.
NOTE: Always wait 5 minutes before restarting the oven. Never run the oven with the Night Heat Retention Door(s)in place. NOTE: Small “crazing” cracks will occur with normal heating and cooling. They will not effect the performance or durability of the oven. If cracks of 1/8" or more develop, contact the Wood Stone Service Department for evaluation. info@woodstone-corp.com M0119.12 DECEMBER 2019...
RFG-(W) DAILY OPERATION Gas-Fired & Gas/Wood Traditional Series Installation and Operation Manual DAILY OVEN OPERATION OVERVIEW RFG AND RFG-W MODELS: DAILY OPERATION 1. Remove the Night Heat Retention Door(s). 2. Push ON/OFF button. Using the Flame Height Control Knob, turn the radiant flame to its highest setting. Check your temperature after approximately one hour.
NOTE: Always wait 5 minutes before restarting the oven. Never run the oven with the Night Heat Retention Door(s) in place. NOTE: Small “crazing” cracks will occur with normal heating and cooling. They will not effect the performance or durability of the oven. If cracks of 1/8" or more develop, contact Wood Stone for evaluation. info@woodstone-corp.com M0119.12 DECEMBER 2019...
RFG-IR-(W) DAILY OPERATION Gas-Fired & Gas/Wood Traditional Series Installation and Operation Manual RFG-IR AND RFG-IR-W OVENS: DAILY OVEN OPERATION OVERVIEW DAILY OPERATION 1. Remove the Night Heat Retention Door(s). 2. Push ON/OFF button, adjust the Hearth Set Point on the Controller to the desired floor temperature. Using the Flame Height Control Knob, turn the radiant flame to its highest setting.
Never use any type of flammable liquid or fuel to start a fire in a Wood Stone oven. Doing so could cause a dangerous situation and/or damage to the oven ceramic.
Page 26
“green” wood, will cause a build-up of residue throughout the exhaust system. (See the FUELWOOD FACTS section of this manual, or consult Wood Stone for information on what types of wood can be used for oven fuel.) The fire should be ignited a couple of hours before the oven needs to be at cooking temperature, and can be located practically anywhere in the oven, far enough inside and of a size that doesn’t permit the flame to go up the flue.
They should be retained in the closed container until all cinders have thoroughly cooled. Check with your dealer about Wood Stone’s Ash Dolly.
Page 28
Ashes can then be disposed of safely. Wood Stone’s stainless steel Ash Shovel and Double Compartment Ash Dolly disposal system offer a safe and convenient way to dispose of ash. Specification sheets may be viewed on the Wood Stone website under Tools & Accessories. info@woodstone-corp.com M0119.12 DECEMBER 2019...
The oven flue and exhaust system will require inspection and cleaning. The exhaust system should be inspected and cleaned per the manufacturer’s and or local code official’s recommendations. Wood Stone recommends cleaning and inspection at least monthly on any ventilation system serving solid fuel equipment.
Wet wood is the most common operational difficulty associated with wood-fired cooking equipment. Wood Stone’s optional Mini-Ligno E Wood Moisture Meter can save you from paying for water when you thought you were paying for wood (see the Tools &...
RFG-(W) OPERATION SEQUENCE Gas-Fired & Gas/Wood Traditional Series Installation and Operation Manual BURNER OPERATION SEQUENCE RFG-(W) OVEN - TYPE 4 CONTROLLER Power on. SV-2 valve powers Igniter and opens Pilot valve. Pilot does not light, SV-2 times out. Pilot lights.
RFG-IR-(W) OPERATION SEQUENCE Gas-Fired & Gas/Wood Traditional Series Installation and Operation Manual BURNER OPERATION SEQUENCE RFG-IR-(W) OVEN - TYPE 2 CONTROLLER Power on. SV-2 valve powers Igniter and opens Pilot valve to Radiant (rear) burner. Pilot lights. Pilot does not light, SV-2 times out.
W-IR OPERATION SEQUENCE Gas-Fired & Gas/Wood Traditional Series Installation and Operation Manual BURNER OPERATION SEQUENCE W-IR OVEN - TYPE 2 CONTROLLER Power on. Floor temperature above Floor temperature below Hearth Set Hearth Set Point Point – Controller sends power to temperature –...
RFG-(W) ELECTRICAL DIAGRAM Gas-Fired & Gas/Wood Traditional Series Installation and Operation Manual RFG MODELS 120 VAC Single RFG XFMR Junction CB 4A Blue Yellow 110-120 VAC 50/60Hz Brown wired by others Radiant White Temperature Controller Thermo Couple...
W-IR ELECTRICAL DIAGRAM Gas-Fired & Gas/Wood Traditional Series Installation and Operation Manual W-IR MODELS 120 VAC IR Only (W-IR) Temperature Controller Control Panel Type 2 Thermo TB4-R Couple TB4-Y Yellow TB3-2 TB1-2 5 orange TB3-5 TB1-6 pink TB4-P Yellow TB1-4...
Any interruption of the power to the oven will cause the oven (including all burners and pilots) to shut off, and it will be necessary to restart the oven by pressing the start switch once power is restored. For additional interlock options, see the Wood Stone Interlock Options supplement in the Manuals section on the website, woodstone-corp.com, or contact Wood Stone for additional information.
See “Radiant flame does not light” above. RFG-(W) Please contact Wood Stone at 1-800-988-8103 should service be necessary, or if you have any questions about your oven. Our service hours are 8am to 5pm Pacific time. Follow the recorded instructions for Emergency Service if you require assistance during non-business hours.
Parts to be replaced under this warranty will be repaired or replaced at the option of Wood Stone with new or functionally operative parts. The liability of Wood Stone on any claim of any...
Page 40
WOOD STONE CORPORATION Toll Free 800.988.8103 1801 W. Bakerview Rd. Tel 360.650.1111 Bellingham, WA 98226 USA Fax 360.650.1166 www.woodstone-corp.com An ongoing program of product improvement may require us to change specifications without notice. M0119.12 DECEMBER 2019...
Need help?
Do you have a question about the Traditional Series and is the answer not in the manual?
Questions and answers