Summary of Contents for Wood Stone CASCADE WS-GFR-6
Page 1
Installation and Operation Manual CASCADE Rotisserie Gas-Fired Rotisserie, Six- and Ten-Spit Models CASCADE WS-GFR-6 CASCADE WS-GFR-10 WOOD STONE CORPORATION Toll Free 800.988.8103 1801 W. Bakerview Rd. Tel 360.650.1111 Bellingham, WA 98226 USA Fax 360.650.1166 www.woodstone-corp.com DOC NO M0049.08 REVISED MARCH 2018...
CASCADE GAS-FIRED ROTISSERIE Cascade Gas-Fired Rotisserie Installation and Operation Manual INSTALLATION AND OPERATION MANUAL FOR THE WOOD STONE CASCADE ROTISSERIE STONE FIRED COOKING EQUIPMENT WS-GFR-6 (SIX SPIT) AND WS-GFR-10 (TEN SPIT) MODELS GAS-FIRED ROTISSERIE ADDITIONAL COPIES AVAILABLE UPON REQUEST WS-GFR-6 shown with left side...
Cascade Gas-Fired Rotisserie Installation and Operation Manual INSTALLATION AND OPERATING INSTRUCTIONS FOR THE GFR-(6, 10)-(NG, LP) WOOD STONE CASCADE GAS-FIRED ROTISSERIE RETAIN THIS MANUAL FOR FUTURE REFERENCE Additional copies of this manual at woodstone-corp�com� For prompt responses to service/maintenance questions, call us at @ 1-800-988-8103�...
Page 5
This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachusetts. SAVE THE INSTRUCTIONS The Wood Stone rotisseries have been tested and approved by Intertek Testing Services and conform to ANSI Z83.11:2016 Ed. 4; is certified to CSA 1.8:2016 Ed. 4 and CGA 2.17, and to NSF/ANSI 4:2016.
F WOOD STONE CORPORATION Rotisserie GAS INLET: 1" NPT OR USE IN PART OR AS A WHOLE UTILITIES SPECIFICATIONS 175,000 BTU, NG N PERMISSION OF WOOD STONE IS 185,000 BTU, LP Electrical Venting PROHIBITED 1 inch FNPT gas inlet 120 VAC, 5 A, 50/60 Hz...
(6) 1/4-20 x 1/2" stainless steel pan head machine screws (supplied) as shown at right� Air Block Panel (6) 1/4-20 x 1/2" stainless steel pan head machine screws WOOD STONE CORPORATION info@woodstone-corp.com M0049.08 MARCH 2018 800.988.8103 TOLL FREE E-MAIL woodstone-corp.com...
REV: WS-GFR-(6,10) lucasm DWN BY: 11/8/2017 DATE: GFR Rotisserie Restraining Hole Location File Location: \\woodstone\dfs\CAD\1_LucasM_Prelim\GFR_Restraini n g_Mount_Hole.dft WOOD STONE CORPORATION info@woodstone-corp.com M0049.08 MARCH 2018 800.988.8103 TOLL FREE E-MAIL woodstone-corp.com 1801 W. Bakerview Rd. 360.650.1111 An ongoing program of product improvement may Bellingham, WA 98226 USA 360.650.1166...
VENTING The Wood Stone Cascade Gas-Fired Rotisserie must be vented using a Listed Type 1 exhaust hood or one constructed in accordance with the Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations, NFPA 96, and all relevant local and national codes, and in a manner acceptable to the authority having jurisdiction�...
Wood Stone recommends that the rotisserie be equipped with a manual, individual shutoff valve, located between the oven and the main gas supply, and that this shutoff valve (supplied by others) be left readily accessible� Wood Stone also recommends that inspection and maintenance of the burners and gas piping connections of this appliance be performed at regularly scheduled intervals and only by professional gas appliance service agencies�...
Page 11
Electrical grounding: This appliance must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical code, ANSI/NFPA 70 or the Canadian Electrical Code, CSA C22�1 as applicable� WOOD STONE CORPORATION info@woodstone-corp.com M0049.08 MARCH 2018...
Supply an incoming gas line sufficient to provide the required input� The gas line will need to be fitted with a 1-inch MNPT connector� See pages INSTALLATION and UTILITY SPECIFICATIONS sections for more information� WOOD STONE CORPORATION info@woodstone-corp.com M0049.08 MARCH 2018 800.988.8103...
(rotisserie drum must be open, depressing the activated before burners button will jog the will light)� drum)� ALWAYS WAIT FIVE MINUTES BEFORE ATTEMPTING TO RELIGHT THE BURNERS. WOOD STONE CORPORATION info@woodstone-corp.com M0049.08 MARCH 2018 800.988.8103 TOLL FREE E-MAIL woodstone-corp.com 1801 W. Bakerview Rd.
Failure to fill the cabinet with water can result in warping of the cabinet and fire hazard from grease accumulation� Wood Stone recommends allowing the water to trickle into the tray while the rotisserie is in use to allow grease to flow safely out of the cabinet through the drain (which must be connected to a grease trap)�...
Page 15
2. Check that power cord is securely connected to the rotisserie and at the outlet� Check that the cord is not damaged� 3. Press the Push Button Circuit Breaker, located in center of Controller� 4. If the above do not solve the problem, call Wood Stone� SPIT LOCATIONS...
Page 16
All rotisserie attachments (spits, forks, basket pins) should be cleaned between uses using an approved mild detergent, hot water, and an approved sanitizing solution� Alternatively, these items can be cleaned in a dishwasher� EXHAUST HOOD Refer to the exhaust hood manufacturer’s recommendations for inspection, maintenance and cleaning� WOOD STONE CORPORATION info@woodstone-corp.com M0049.08 MARCH 2018 800.988.8103...
Cascade Gas-Fired Rotisserie Installation and Operation Manual A. STANDARD ANGLE SPIT The Standard Angle Spit is included with all Wood Stone rotisseries� Six to seven average-sized birds can be quickly loaded� The perforations are convenient for securing the string or skewers used to bind the legs�...
Page 18
N. PUSH RELEASE BASKET PIN Replacement locking pin on the Chain Assembly For Clamshell Basket� See the Tools and Accessories Catalog on the Wood Stone website for additional details. WOOD STONE CORPORATION info@woodstone-corp.com M0049.08 MARCH 2018 800.988.8103 TOLL FREE E-MAIL woodstone-corp.com...
One pump is sufficient� MOTOR BRUSHES REPLACEMENT (APPROXIMATELY EVERY 3 YEARS) The three year replacement recommendation is based upon an average daily use of 10 hours� Contact the Wood Stone Service Department or your local service technician for service�...
LIMITATIONS OF LIABILITY In the event of warranty claim or otherwise, the sole obligation of Wood Stone shall be the repair and/or replacement, at the option of Wood Stone, of the appliance or component or part thereof� Such repair or replacement shall be at the expense of Wood Stone with the exception of travel over 100 miles or two hours, overtime, and holiday charges which shall be at the expense of the purchaser�...
Page 26
This page left intentionally blank� M0049.08 MARCH 2018...
Page 27
This page left intentionally blank� M0049.08 MARCH 2018...
Page 28
WOOD STONE CORPORATION Toll Free 800.988.8103 1801 W. Bakerview Rd. Tel 360.650.1111 Bellingham, WA 98226 USA Fax 360.650.1166 www.woodstone-corp.com An ongoing program of product improvement may require us to change specifications without notice. M0049.08 MARCH 2018...
Need help?
Do you have a question about the CASCADE WS-GFR-6 and is the answer not in the manual?
Questions and answers