Summary of Contents for Wood Stone BISTRO LINE 3030
Page 1
Service Manual BISTRO LINE - CE Stone Hearth Oven Gas-Fired, Gas/Wood Combination, European Models BISTRO LINE 3030 WS-BL-3030-RFG-CE BISTRO LINE 4343 WS-BL-4343-RFG-(W)-CE BISTRO LINE 4355 WS-BL-4355-RFG-(W)-CE BISTRO LINE 4836 WS-CS-REC-8-RFG-CE WOOD STONE CORPORATION 1801 W. Bakerview Rd. Tel +1.360.650.1111 Bellingham, WA 98226 USA Fax +1.360.650.1166...
CAUTIONS & WARNINGS Bistro CE Service Manual INSTALLATION AND OPERATION MANUAL FOR THE WOOD STONE BISTRO CE MODEL OVEN NATURAL GAS (NG) OR PROPANE (LP) FUELED STONE HEARTH OVEN WS-BL-(3030, 4343, 4355) CE MODELS RETAIN THIS MANUAL FOR FUTURE REFERENCE Additional copies of this manual and prompt responses to service/maintenance questions are available from your local Wood Stone distributor�...
OPERATIONAL OVERVIEW Bistro CE Service Manual WOOD STONE BISTRO OVEN CE EUROPEAN MODELS Power ON Control displays floor temperature- Control sends power to ICS module� ICS module sends spark to Igniter and powers Pilot Solenoid on Gas Valve� Pilot does not light- ICS module will Pilot lights, ICS module senses Pilot retry for 90 seconds�...
(Throttle) Filter fuses (New as of Control Valve Control Valve 1/26/17) info@woodstone-corp.com M0013.04 APRIL 2018 WOOD STONE CORPORATION 800.988.8103 TOLL FREE E-MAIL woodstone-corp.com 1801 W. Bakerview Rd. 360.650.1111 An ongoing program of product improvement may Bellingham, WA 98226 USA 360.650.1166 require us to change specifications without notice.
Valve Junction Box Radiant Burner Assembly Igniter Wire Flex Piping to Burner Pilot Tube info@woodstone-corp.com M0013.04 APRIL 2018 WOOD STONE CORPORATION 800.988.8103 TOLL FREE E-MAIL woodstone-corp.com 1801 W. Bakerview Rd. 360.650.1111 An ongoing program of product improvement may Bellingham, WA 98226 USA 360.650.1166...
Turn power back on and retry� If 24 VAC is still not present at the output of the Transformer, replace the Transformer� Continued on next page. info@woodstone-corp.com M0013.04 APRIL 2018 WOOD STONE CORPORATION 800.988.8103 TOLL FREE E-MAIL woodstone-corp.com 1801 W. Bakerview Rd.
Page 8
When oven is turned ON there should be 24 VAC at the output terminals on the Controller (Brown and White wires)� If 24 VAC not present when Controller is turned ON, replace Controller� Continued on next page. info@woodstone-corp.com M0013.04 APRIL 2018 WOOD STONE CORPORATION 800.988.8103 TOLL FREE E-MAIL woodstone-corp.com 1801 W. Bakerview Rd.
Page 9
The Pilot should be lit and within a few seconds the main Burner should light� Continued on next page > info@woodstone-corp.com M0013.04 APRIL 2018 WOOD STONE CORPORATION 800.988.8103 TOLL FREE E-MAIL woodstone-corp.com 1801 W. Bakerview Rd.
Page 10
Jets are clean and that the Pilot/Igniter has not been knocked out of position� The base of the Pilot/Igniter Assembly should be horizontal, even with the top of the Burner� info@woodstone-corp.com M0013.04 APRIL 2018 WOOD STONE CORPORATION 800.988.8103 TOLL FREE E-MAIL woodstone-corp.com 1801 W.
Page 11
Correct the airflow problem and make sure the Igniter gasket is in place� There should be no discernible airflow beneath the oven� 5. Defective Pilot/Igniter, replace. If Burner is still cutting out, replace Gas Control Valve� info@woodstone-corp.com M0013.04 APRIL 2018 WOOD STONE CORPORATION 800.988.8103 TOLL FREE E-MAIL woodstone-corp.com 1801 W. Bakerview Rd.
Page 12
Inspect Thermocouple wire for damage� 2. Damaged Thermocouple. Unplug the Thermocouple connector and check for continuity between the two leads� If there is no continuity replace the Thermocouple� info@woodstone-corp.com M0013.04 APRIL 2018 WOOD STONE CORPORATION 800.988.8103 TOLL FREE E-MAIL woodstone-corp.com 1801 W. Bakerview Rd.
CHECKING BURNER GAS PRESSURES Proper gas pressure settings and an adequate incoming gas supply are critically important for any gas-fired Wood Stone oven to operate correctly� Burner gas pressure measurements should be taken at the outlet port on the Gas Control Valve� Make sure that the Throttle Valve is fully open (maximum flame height) when taking the pressure reading�...
Page 14
7. Plug the new Thermocouple into the back of the Control Box� info@woodstone-corp.com M0013.04 APRIL 2018 WOOD STONE CORPORATION 800.988.8103 TOLL FREE E-MAIL woodstone-corp.com...
Pilot / Igniter—LP 70CE-0020-LP Pilot Gasket 7000-0777 Ignition (ICS) Module—Fenwal 70CE-0022 SV-2 Gas Control Valve—Specify Gas Type Contact Wood Stone Transformer for 200–240 VAC input 70CE-0026 2 A Fuse 70CE-0063 5 A Fuse 70CE-0061 Fuse Holder for either 5 A or 2 A Fuse...
WIRE DIAGRAMS-PRE-2005 Bistro CE Service Manual BISTRO RFG CE MODELS PRODUCED BEFORE APRIL 2005 info@woodstone-corp.com M0013.04 APRIL 2018 WOOD STONE CORPORATION 800.988.8103 TOLL FREE E-MAIL woodstone-corp.com 1801 W. Bakerview Rd. 360.650.1111 An ongoing program of product improvement may Bellingham, WA 98226 USA 360.650.1166...
info@woodstone-corp.com M0013.04 APRIL 2018 WOOD STONE CORPORATION 800.988.8103 TOLL FREE E-MAIL woodstone-corp.com 1801 W. Bakerview Rd. 360.650.1111 An ongoing program of product improvement may Bellingham, WA 98226 USA 360.650.1166 require us to change specifications without notice.
info@woodstone-corp.com M0013.04 APRIL 2018 WOOD STONE CORPORATION 800.988.8103 TOLL FREE E-MAIL woodstone-corp.com 1801 W. Bakerview Rd. 360.650.1111 An ongoing program of product improvement may Bellingham, WA 98226 USA 360.650.1166 require us to change specifications without notice.
LIMITATIONS OF LIABILITY In the event of warranty claim or otherwise, the sole obligation of Wood Stone shall be the repair and/or replacement, at the option of Wood Stone, of the appliance or component or part thereof� Such repair or replacement shall be at the expense of Wood Stone with the exception of travel over 100 miles or two hours, overtime, and holiday charges which shall be at the expense of the purchaser�...
Page 20
WOOD STONE CORPORATION 1801 W. Bakerview Rd. Tel +1.360.650.1111 Bellingham, WA 98226 USA Fax +1.360.650.1166 www.woodstone-corp.com An ongoing program of product improvement may require us to change specifications without notice. M0013.04 APRIL 2018...
Need help?
Do you have a question about the BISTRO LINE 3030 and is the answer not in the manual?
Questions and answers