ENGLISH You have purchased a product made by Pentair Jung Qualification and training of personnel All personnel involved with the operation, servicing, inspection Pumpen and with it, therefore, also excellent quality and and installation of the equipment must be suitably qualified service.
INSTALLATION The pump must never be used when a person is in the water. U2 KS submersible pumps are suitable for pumping domes- For installations in accordance with EN 12056-4, the pressure tic waste water without stones. This includes also water from pipe must be laid in a loop above the local backflow level and household dishwashers and household washing machines.
ENGLISH level available, for U2: 40 mm. CAUTION! Do not touch the pump until all rotating parts have come to a CAUTION! standstill. For safety reasons, mobile operation is only allowed with a foot NOTICE! If the water contains high levels of iron or lime, insuf- strainer.
Page 6
Varaosat - Części zamienne - Náhradní díly - Alkatrészek - Piese de schimb - Запасные части - 备件 ① Schwimmer Float JP42771 ② Kondensator Capacitor JP46353 ③ Anschlusseinheit Top cover U2 KS, 4m JP50035 U2 KS, 10 m JP50036 U2 KS, 10m, ANZ JP50037 ④ Mikroschalter Microswitch JP46351 ⑤ Schaltwelle Shift shaft JP42770 ⑥ Motor...
Page 7
EU-Konformitätserklärung EU-Déclaration de Conformité EU-Declaraţie de conformitate EU-Prohlášeni o shodě EU-Megfelelöségi nyilatkozat EU-Vyhlásenie o zhode EU-Overensstemmelseserklæring EU-Dichiarazione di conformità EU-Försäkran om överensstämmelse EU-Declaration of Conformity EU-Conformiteitsverklaring EU-Vaatimustenmukaisuusvakuutus EU-Deklaracja zgodności DE - Richtlinien - Harmonisierte Normen FR - Directives - Normes harmonisées RO - Directivă...
Need help?
Do you have a question about the U2 KS and is the answer not in the manual?
Questions and answers