Summary of Contents for Pentair Jung Pumpen U5

  • Page 1 U5 - U6 U5 K U6 KE U6 KD U5 KS U6 KES U6 KDS DE Original- Instruction Manual Instrukcja eksploatacji Betriebsanleitung Instructions de service Návod pro provoz Gebruikshandleiding Návod na prevádzku Istruzioni per l‘uso Üzemeltetési útmutató Manual de utilizare JUNG-PUMPEN.DE...
  • Page 2: Safety Instructions

    ENGLISH You have purchased a product made by • Installation of backflow protection for drain- age units that can be damaged by wastewater JUNG PUMPEN and with it, therefore, also leakage upon product failure. excellent quality and service. Secure this •...
  • Page 3 The use of other parts can result in liability in the water. for consequential damage being rescinded. Submersible pumps from the U5 and U6 series Unauthorised operating methods are suitable for pumping domestic waste water without stones. This includes also water from...
  • Page 4 Dimensions [mm] to -20°C when stored in dry conditions. When installed, however, it must not be allowed to freeze in the water. U5 K Transport U6 K The pump must always be lifted by the handle Pumps with special float assembly, (JP44207)
  • Page 5: Electrical Connection

    The rubber Observe the operating voltage (see the type flap supplied (U5) is for mobile operation only. plate)! A correspondingly larger diameter pipe should The pump is provided with a winding thermo- be used for longer pressure pipelines to avoid stat.
  • Page 6 When reattaching the foot strainer, ensure that the new drill-holes are not covered by the bars of the foot strainer. The U5 and U6 ranges provide markings on the housing and the foot strainer to help you.
  • Page 7: Maintenance

    The foot strainer prevents coarse impurities from entering the pump. Regular cleaning of the The free passage of the U5 and U6 pump ranges float and the foot strainer ensures optimum per- can be enlarged from 10 to 20 mm. This is done formance and operation.
  • Page 8: Quick Tips For Remedying Faults

    • Empty the pressure pipe or hose to allow the U6 K E (JP00226/2) non-return valve to open and the air to escape U6 K D (JP00228/3) U5 K (JP09386/0) from the pump housing, it may be necessary U6 K ES (JP00227/2) U5 KS (JP09387/0)
  • Page 9 VDE GS 40054271 (U3/3, UV3) EMC-VDE 92272 (U6 E/D/1) JUNG PUMPEN - Stefan Sirges - Industriestr. 4-6 - 33803 Steinhagen EMC-VDE 40052857 (U3/3, UV3) Steinhagen, 20-12-2022 VDE GS 40020521 (U3/2, U5) EMC-VDE 40020827 (U5) VDE GS 40020499 (U6K D/3) ______________________ i.V. ____________________...