Summary of Contents for Pentair Jung Pumpen MULTISTREAM EX 75/4 C5 EX
Page 1
MULTISTREAM 55/2 B2 75/2 B5 100/2 B5 55/2 B2 EX 75/2 B5 EX 100/2 B5 EX 55/4 B6 75/4 B6 100/4 C2 55/4 B6 EX 75/4 B6 EX 100/4 C2 EX 55/4 C2 75/4 C2 100/4 C5 55/4 C2 EX 75/4 C2 EX 100/4 C5 EX 55/4 C5...
Page 2
ENGLISH You have purchased a product made by Pentair Jung Pum- Qualification and training of personnel All personnel involved with the operation, servicing, inspection pen and with it, therefore, also excellent quality and service. and installation of the equipment must be suitably qualified Secure this service by carrying out the installation works for this work and must have studied the instruction manual in in accordance with the instructions, so that our product...
Page 3
ENGLISH For installations in areas subject to explosion hazards, special ELECTRICAL CONNECTION regulations apply! Circuitry AREAS OF APPLICATION Submersible pumps in the MultiStream range are suitable for pumping wastewater in municipal and industrial pumping sta- tions, and in rainwater retention tanks. MultiStream pumps are favoured for use with: –...
Page 4
ENGLISH INSTALLATION WARNING! After an automatic cut-out via the temperature limiters, the ATTENTION! Before the pump can be installed, the 4 plastic cause of the malfunction must first be eliminated. Only then may the motor be switched on again manually. packaging feet must be unscrewed from the bottom of the pump housing and removed.
Page 5
ENGLISH This situation can also occur if the pump runs dry, pumps down NOTICE! The oil reservoir may only be filled with the specified to a lower lever than that shown in the installation drawing, or quantity of oil. Overfilling will result in the pump being rendered runs in "snore"...
Page 6
ENGLISH a new seal. 4. Tighten the four cylinder head screws again. 5. After this, readjust the impeller gap again. Replacing the impeller CAUTION! Worn impellers can have sharp edges. 1. Remove the 4 hexagonal screws and lift the motor unit off the spiral housing.
Page 7
DEUTSCH ENGLISH 0197 0197 JUNG PUMPEN GmbH - Industriestr. 4-6 - 33803 Steinhagen, Germany JUNG PUMPEN GmbH - Industriestr. 4-6 - 33803 Steinhagen, Germany 412.14.1910 412.14.1910 EN 12050-1:2001 EN 12050-1:2001 Fäkalienhebeanlage Lifting plant for wastewater containing faecal matter 55/2 B2 (JP09663/2) 55/2 B2, EX (JP09664/2) 55/2 B2 (JP09663/2) 55/2 B2, EX (JP09664/2)
Page 21
MULTISTREAM 55/2 Spare parts ① Leitung Cable 10 m JP46575 JP46576 EX, 10 m EX, 15 m JP46634 EX, 20 m JP46635 EX, 25 m JP46636 EX, 30 m JP46637 ② Schäkel Shackle JP45904 ③ Stator + Gehäuse Stator + Housing JP47141 ④...
Page 22
MULTISTREAM 55/4 - 100/4 ① Leitung Cable 10 m JP46575 EX, 10 m JP46576 JP46634 EX, 15 m EX, 20 m JP46635 EX, 25 m JP46636 EX, 30 m JP46637 ② Schäkel Shackle JP45904 ③ Stator + Gehäuse Stator + Housing 55/4 JP47142 75/2...