For further information regarding the installation of your product, refer to the Smart Shower Installation Guide. Declaration of Conformity Aqualisa Products Limited declares that the Elisa ® SmartValve and supplied controller, in conjunction with...
GET SMART CONNECTED Unlock the potential of your shower; from water consumption analysis to enhanced user functions. Keep up to date with latest features for the Aqualisa® App and voice activation by visiting the Elisa website and download the free Aqualisa®...
Quick Start You can prepare your temperature and outlet before you switch on the shower, or adjust with ease while showering. WAKE UP, (POWER ON) SHOWER ON AND POWER OFF TEMPERATURE FLOW SELECT OUTLET* Adjust before or Adjust during Push and hold lever for over 3 seconds then release when during showering.
Page 5
Wake-up The controller has a proximity sensor, so as you approach or move your hand towards the controller, the display wakes up and is ready to go. (You can disable this feature in the Settings menu - see page 13). 0.5 metres The proximity sensor detects any object directly in front,...
20 minutes. The flow can be stopped and started at any time by following the instruction on this page. This can be enhanced by activating and using the free Aqualisa® App. See page 3.
Adjusting the Temperature From the Home screen you can adjust the temperature at any time, before or during showering, by turning the bezel. TIP: This is your Home screen. When in any of the Menu or Settings screens, you can easily return to the home screen by turning the temperature bezel.
Adjusting the Flow From the Home screen you can adjust the flow during showering, by moving the lever left or right.* FLOW FEEDBACK DISPLAY Flow Flow After adjusting the flow, the display will return to the temperature Home screen after a few seconds. Note: the change in flow will vary depending on the water system pressure and the configuration of the pipework.
Selecting your Outlet Divert models only From the Home screen, you can alternate between outlets by pushing and holding the lever for over 3 seconds and releasing when the desired outlet icon appears. This can be done upon starting the shower, or during showering.
Adjustable Head Vita™ Head 1. Inner To avoid water dripping from the shower head after use, we advise to tilt the head back to allow residual water to drain out. The above recommendation applies to both adjustable and fixed shower heads. 2.
Fixed Head The angle of the fixed shower head can be adjusted. The shower head is mounted on a multi directional ball joint to allow for minor angular adjustment in any direction by carefully holding the shower head and moving the head to the desired angle. To avoid water dripping from the shower head after use, we advise to tilt the head to allow residual water to drain out.
Settings Intuition™ features optional settings to enhance your shower. To enter Settings, from the Home Screen, move the lever left or right until the Settings screen appears. Push the lever to enter. Access to the settings menu is only available when water is not flowing. HOME SETTINGS BROWSING THE SETTINGS...
Page 13
Settings AUTO WAKE UP WIFI This setting allows To connect to the the Wake Up feature Aqualisa® App and Auto Wake up Wifi to be turned off. This enable shower may be required if functionality using you have a small...
Configuring your Outlets This setting enables you to choose the icons that represent your outlets. If you have multiple outlets, Confi gure Outlets you can also select the most commonly used, this is known as the primary outlet. Water will divert to this outlet unless you select otherwise.
Caring for your Shower Over time, your shower may be affected by hard water scaling. To keep your shower working effectively, we recommend that you clean your shower regularly. Your product should be cleaned using only a soft cloth and washing up liquid. The bath system ‘click clack’...
Shower Troubleshooting Symptom Possible cause Action Controller Power supply Check power supply is turned on - Green unresponsive - turned off to Elisa power light should be illuminated on the Elisa No Lights / SmartValve SmartValve . Additionally check the following 2 Blank action points.
Page 17
Symptom Possible cause Action Low / no flow Seasonal conditions See previous point. Incorrect If water supplies are gravity fed, the PUMPED Elisa SmartValve Elisa SmartValve must be used (unless a fitted separate stand alone pump is being utilised). Refer to the Smart Shower Installation Guide. Water supply issue For the Standard Elisa SmartValve - Ensure...
Page 18
Symptom Possible cause Action Fluctuating Hot water temperature Ensure hot water supply temperature is below water too high 65ºC (minimum 55ºC for stored water and 50ºC temperature for combination boilers). (continued) Communications issue Check data cable connections and that there is no visible damage.
Page 19
Symptom Possible cause Action Maximum Settings need Refer to section 'Temperature too low', possible temperature adjusting cause 'Logic module setting too low'. setting is not to your preference Controller remains Poor cable connection Check data cable connections are making good illuminated after contact, are fully inserted and that there is no switching shower...
Have you Registered? Our products are manufactured to the highest standards. In the unlikely event that something goes wrong, we want all our customers to be protected, which is why we give you a totally free of charge 1 year parts and labour guarantee*.
Need Help? You can find Frequently Asked Questions at elisabathrooms.com Speak to our Customer Service team on 01959 560003 Or email us at enquiries@elisabathrooms.com...
Page 24
www.elisabathrooms.com The Flyers Way, Westerham, Kent TN16 1DE, UK Register your guarantee instantly at www.elisabathrooms.com/guarantee Speak to our Customer Service team on 01959 560003 The company reserves the right to alter, change or modify the product specifications without prior warning. Q5938 Part No 705735 Issue 03 - Jan 23...
Need help?
Do you have a question about the Elisa Intuition and is the answer not in the manual?
Questions and answers
Can I disconnect the pump on the Elisa as customer has now changed to a mains fed system