If you have any questions at any stage during installation then please contact the Aqualisa customer helpline on 01959 560010 for advice. The Aquastream Thermo shower system is designed to operate up to a maximum static pressure of 0.1 MPa (1 bar) (14.5 psi).
Supply lines should be flushed clear of any debris prior to installation of the unit. The Aquastream Thermo is supplied for connection to conventional supplies with HOT on the LEFT and COLD on the RIGHT when viewed from the front.
Page 6
Aqualisa customer helpline for assistance. Siting The Aquastream Thermo unit must be sited so that the top of the casing is below the underside of the cistern. The casing must not be sited where it is subjected to continuous spray from the shower head.
Page 7
CYLINDER TEMPERATURE IN EXCESS OF 65ºC MAY RESULT IN POOR SHOWER PERFORMANCE. Pipe work can generally be run in 15mm. A typical layout is shown on the reverse of this guide. Aquastream Thermo installation instructions Page 7...
Page 8
BS 7671 (Wiring Regulations) and certified to current building regulations. The Aquastream Thermo is supplied with universal fixings. Using the template provided, mark out the fixing points and entry point for the low voltage cable and rear entry pipe work as necessary.
Page 9
Remove the fixing screw from the top of the Aquastream Thermo casing and pull the front cover away from the unit. The Aquastream Thermo has been designed to accept rear entry concealed pipe work or exposed top or bottom entry pipe work. Aquastream Thermo installation instructions...
Page 10
Lubricate the supply pipe ends using a silicone based lubricant and carefully slide the Aquastream Thermo unit onto the pipes whilst feeding the low voltage cable through the cable entry point. Secure the unit to the wall using the screws provided.
Page 11
These should be inserted into the locking collets and depressed as the pipes are withdrawn. Proceed to step 17. Aquastream Thermo installation instructions Page 11...
Page 12
20-35mm to allow for full retention by the gripper rings located in the bottom fitting. Lubricate the supply pipe ends with a silicone based lubricant and push into the unit fully home. Aquastream Thermo installation instructions Page 12...
Secure using the fixing screw at the top of the front cover ensuring not to overtighten. Aquastream Thermo installation instructions Page 13...
Page 14
THE POWER SUPPLY TO THE AQUASTREAM THERMO MUST BE ISOLATED BEFORE REINSTATING THE DOMESTIC ELECTRICAL SUPPLY. ALL COPPER PIPE WORK MUST BE CROSS BONDED AND CONNECTED TO A RELIABLE EARTHING POINT.
Page 15
Place the top fixing bracket into position and secure to the wall using the screws provided, if suitable. Slide the rail end covers onto the rail brackets and click into position. Aquastream Thermo installation instructions Page 15...
Page 16
Pass the hose through the gel hook. Ensuring the hose washers are in the correct position, depress the anti-swivel locking button on the handset and secure the handset to the hose. Place the handset into the handset holder. Aquastream Thermo installation instructions Page 16...
Page 17
Part No:243801 Issue 05 May 11 Please note that calls may be recorded for training and quality purposes The company reserves the right to alter, change or modify the product specifications without prior warning ® Registered Trademark Aqualisa Products Limited...
Page 18
Digital Showers Mixer Showers Power Showers Smart Showers Shower Towers From Top Shower Brands Mira Showers Aqualisa Showers Triton Showers Gainsborough Showers Shower Pumps can upgrade your showering experience even more Stuart Turner Shower Pumps Salamander Shower Pumps Grundfos Shower Pumps...