  • Page 1 Installation Manual (Translation of original language) N421097A - Rev. 01 - 07/2024 AirLeaf SL - RS - SLS (with visible cabinet)
  • Page 2 By following the suggestions contained in this manual, the product you have purchased will operate without problems giving you optimum room temperatures with minimum energy costs. INNOVA S.r.l. Conformity This unit complies with the European directives: •...
  • Page 3: Table Of Contents

    TabLE of CoNTENTS TABLE OF CONTENTS Coding                                                                     p. 5 1.1 Product related coding .
  • Page 4 TabLE of CoNTENTS 4.11.1 Preliminary warnings ........p. 20 4.11.2 Device preparation .
  • Page 5: Product Related Coding

    CoDINg CODING 11 Product related coding This instruction manual refers to the following product codes. Check the correspondence with the technical rating plate on the product. See chapter "Identification" p. 10. FASL02DC1II SL 200 Vertical right FASL02OC1II SL 200 Horizontal left FASL02RC1II SL 200 Horizontal right FASL02SC1II SL 200 Vertical left FASL04DC1II SL 400 Vertical right FASL04OC1II SL 400 Horizontal left...
  • Page 6 CoDINg FA4L08SC1II SL 800 4 PIPES Vertical left FA4L10DC1II SL 1000 4 PIPES Vertical right FA4L10OC1II SL 1000 4 PIPES Horizontal left FA4L10RC1II SL 1000 4 PIPES Horizontal right FA4L10SC1II SL 1000 4 PIPES Vertical left FARS02DC1II RS 200 Right vertical FARS02SC1II RS 200 Vertical left...
  • Page 7: General Information                                                        P

    gENERaL INfoRMaTIoN GENERAL INFORMATION 21 About the manual  I nthefigures This manual was written to provide all the explanations for the correct management of the appliance. 1 The numbers indicate the individual components. This instruction manual forms an integral part of the a The capital letters indicate component assemblies.
  • Page 8: General Warnings

    gENERaL INfoRMaTIoN Coding Installation It addresses all recipients. It is addressed exclusively to the installer. It contains the list of products and/or accessories referred It contains specific warnings and all the information nec- to in the manual. essary for positioning, mounting and connecting the ap- pliance.
  • Page 9: Disposal

    gENERaL INfoRMaTIoN It is forbidden to introduce objects and substances It is forbidden to dispose of, or leave in the reach of through the air inlet and outlet grilles. children, the packaging materials which could become a source of danger. It is forbidden to open the access doors of the device's internal parts without first having set main switch of the system to" off".
  • Page 10: Product Presentation                                                      P

    PRoDUCT PRESENTaTIoN PRODUCT PRESENTATION 31   I dentification The appliance can be identified by the rating plate: Technical rating plate Tampering with, removal of, or lack of identification plates will not allow for the safe identification of the product by its serial number and therefore invalidates the warranty. Technical rating plate 32 Destination of use These appliances have been designed for conditioning...
  • Page 11: Components

    PRoDUCT PRESENTaTIoN Check the type of appliances you have with the chapter "Product related coding" p.  5, using the appliance code. 34 Components Cover cabinet Wall mounting brackets fan motor Condensation drain tray Side panels Air filter Preparation for on-board control (accessory) Heat exchanger Intrusion protection grid front grid...
  • Page 12: Compatible Accessories

    PRoDUCT PRESENTaTIoN 35 Compatible accessories Check the matching products column for a match with the size purchased. Accessory description Combinable products Code Controls on the appliance Control panels 2 PIPES On-board electronic control with 4 fixed speeds and thermostat E2T543II (1) 2 PIPES SMART TOUCH on-board electronic control with 4 fixed speeds and E4T643II (1)
  • Page 13 LED electronic control panel with touch interface, wall-mounted complete with thermostat and room temperature and relative humidity EFB749II probe with integrated WiFi module, App Innova Butler. Cable connection. Colour white LED electronic control panel with touch interface, wall-mounted complete with thermostat and room temperature and relative humidity EGB749II probe.
  • Page 14 PRoDUCT PRESENTaTIoN Accessory description Combinable products Code Modules MZS, Single zone module. Electronic board for external terminal control (e.g. radiant panel or radiator valves). For connection to wall control EG1028II units EEA649II/EEB649II/EEB749II Reversal attacks (motor connection cable for LEFT hydraulic connections Hydraulic connection reversal kit BB0646II (1) 1.
  • Page 15 PRoDUCT PRESENTaTIoN Accessory description Combinable products Code SL 200 SL 400 3 way valve group (with inlet 3 way valve, shut off valve, and electro thermal SL 600 V30361II (1) motor SL 800 SL 1000 Air sterilisation UV-C device for air sterilization SL 200 SL 400 Air sterilization device with UV-C lamp...
  • Page 16: Installation                                                               P

    INSTaLLaTIoN INSTALLATION 41 Preliminary warnings This section is dedicated to the Installer. The fea- During the installation, it is necessary to observe the tures of the installer are described in the "Recipi- precautions mentioned in this manual, and on the la- ents"...
  • Page 17: Handling With Packaging

    INSTaLLaTIoN SL 4 pipes 1000 1000 Models m.u. Dimensions and weight for shopping Width 1135 1335 1535 1137 1337 1537 Height Total depth Weight 18,0 20,0 23,0 26,0 29,0 18,0 21,0 25,0 28,0 32,0 AirLeaf AirLeaf AirLeaf AirLeaf AirLeaf AirLeaf AirLeaf AirLeaf AirLeaf...
  • Page 18: Unpacking

    INSTaLLaTIoN 46 Unpacking 461 Preliminary warnings Handle with care. The packing material (cardboard, staples, plastic bags, Check that no components were damaged during etc.) must not be dispersed or abandoned in the sur- transport. rounding environment and must be kept out of chil- Dispose of the packaging components following the ap- dren reach, as it can be dangerous.
  • Page 19: Installation Mode

    INSTaLLaTIoN • narrow places where the sound level of the appliance • the wall surface is perfectly levelled can be enhanced by reverberations or resonances • there are no obstacles to the free circulation of air • environments with the presence of flammable or ex- • the appliance must be installed in a position where it plosive gases can be easily serviced •...
  • Page 20: Positioning

    INSTaLLaTIoN 411 Positioning The assembly steps described below and their draw- Intrusion protection grid ings refer to a version of the machine with connec- tions on the left side. 4111 Preliminary warnings The unit required two or more people to position the unit.
  • Page 21: Positioning For Vertical Configurations

    INSTaLLaTIoN Front grille removal ► lift the front grille ► pull and remove the grille front grid The front grille is not always present in all versions. 4113  P ositioningforverticalconfigurations The units are supplied with a paper template for mark- ►...
  • Page 22: Positioning For Horizontal Configurations

    INSTaLLaTIoN fixing brackets front grid Unit Clamp fixing screws Screws ► Attach the unit to the fixing brackets ► insert the screws into the grille fin holes and secure ► check right attachment to the fixing brackets To prevent accidental removal of the grille, thus pre- ► Secure the unit with the fixing screws venting the proper operation of the fan coil unit, two ► reassemble the unit screws are provided for fixing the front grille.
  • Page 23: Hydraulic Connections

    INSTaLLaTIoN ► use a leveler fixing screws Unit ► check the inclination towards the attachment side ► fix the screws a maximum inlination of 1° toward the condensate drain connection is allowed to facilitate the drainage of condensate. front grid Clamp Screws ►...
  • Page 24: Position And Dimensions

    INSTaLLaTIoN 4122 Position and dimensions AirLeaf SL, RS, SLS 1000 Models m.u. Pipeline diameter for dimensional information, refer to chapter "Techni- avoid partial insulation of the pipes. cal information" p. 37. avoid over-tightening the pipes to avoid damage to the insulation. 4123 System connection Carefully check that the insulation is tight, in order to To make the connections:...
  • Page 25: Condensate Drain Dimensions

    INSTaLLaTIoN for vertical installations, the pump must be installed under the side drain pan. for horizontal installations, the pump should be in- stalled according to specific requirements. If using an open drain: Drain the condensate liquid flow directly onto a gutter or into a "white water" drain If the condensation is not collected, it will be deposited on the support surface.
  • Page 26: Filling The System

    INSTaLLaTIoN Liquid drain pipe Unit ► connect the condensate drain pipe to the copper pipe ► direct the liquid drain pipe towards a suitable location 4135 Check for drainage ► keep a minimum slope of 3% towards the drain lo- Make sure that: cation •...
  • Page 27: Mounting The Thermostatic Head

    INSTaLLaTIoN 4141 Mounting the thermostatic head To fill the system: ► open the vent valves To mount the thermostatic head: ► open all the system's shut-off devices ► tighten the head to the valve body ► slowly open the water tap To facilitate the system mounting, filling and venting oper- for vertically installed models, act, using a screwdriver, ations, even without electric power, the thermostatic head on the battery vent located higher up.
  • Page 28: Access To The Terminal Block

    INSTaLLaTIoN 1000 Models m.u. Power conductor (phase+neutral) mm² protective conductor section on ground mm² Circuit breaker 4153 Access to the terminal block fixing screws Terminal block for wiring Cover of the electrical box 4154 Power supply connection before doing any work, make sure that the supply pow- er is disconnect.
  • Page 29 INSTaLLaTIoN Connection Terminal block for wiring Power supply cables Quick-connect terminal Earth connection To make the connections: ► use the supplied quick terminal ► connect phase and neutral (L-N) to the quick terminal ► connect the quick-connect terminal to the terminal block ►...
  • Page 30: Maintenance                                                              P

    MaINTENaNCE MAINTENANCE Routine maintenance is essential to keep the device always efficient, safe and reliable over time. 51 Preliminary warnings This section is dedicated to the Technical Service after completing the maintenance work, must be re- Assistance. The features of the Technical Ser- stored the original condition. vice Assistance are described in chapter "Recipi- Warnings: ents"...
  • Page 31: Air Intake Filter Cleaning

    MaINTENaNCE 522   A irintakefiltercleaning Cleaning the filter must be carried out: • when you plan to restart the system after prolungate • after prolonged operation, considered the concentra- disuse tion of impurities in the air 523 Filter extraction Versionwithfinnedintakegrill Air intake grill with fins filter...
  • Page 32 MaINTENaNCE Version with mobile intake panel Mobile intake panel filter To removing the filter in versions with mobile intake panel: ► press the plastic tabs at the lower ends of the mobile panel ► lift the mobile panel slightly ► rotate until the complete exit from the housing ►...
  • Page 33 MaINTENaNCE  C leaningthefilters Vacuum cleaner filter To clean the filter: ► aspirate dust ► use a vacuum cleaner Water flow filter If the quantity of dust is considerable: ► wash the filter under running water (max. 40 °C) ► allow to dry in the shade Exposure to the sun or washing water temperatures above 40 °C can shrink the filters.
  • Page 34 MaINTENaNCE Filter installation Versionwithfinnedintakegrill filter filter housing To reassemble the filter: ► bring the filter closer to the unit ► insert the filter into its housing ► bring the finned grill closer ► insert the grill into the appropriate slots ► rotating the grill ► hooking the grill Check that the filter is fitted correctly. It is forbidden to use the unit without a filter.
  • Page 35: Suggestions For Energy Saving

    MaINTENaNCE Version with mobile intake panel filter filter housing Mobile panel To reassemble the filter: The appliance is equipped with a safety switch that pre- ► bring the filter closer to the unit vents fan operation in the absence or with a poorly po- ► insert the filter into its housing sitioned moving panel.
  • Page 36: Preliminary Warnings

    TRoUbLESHooTINg TROUBLESHOOTING 61 Preliminary warnings Should you encounter any of the anomalies below: ► disconnect the device from power supply immediate- • the ventilation does not start even if the water circuit is filled with hot or cold water ► close the water taps • the device is losing water in heating mode ►...
  • Page 37 TECHNICaL INfoRMaTIoN TECHNICAL INFORMATION 71 Technical data 711 Technical data AirLeaf SL AirLeaf SL - 2 PIPES versions AirLeaf SL 1000 Models m.u. Cooling performances (W 7/12 °C; A 27 °C) (1) Total cooling capacity 0,91 2,12 2,81 3,30 3,71 Sensible cooling capacity 0,71 1,54...
  • Page 38 TECHNICaL INfoRMaTIoN AirLeaf SL 1000 Models m.u. Sound pressure level at maxi- dB(A) mum air flow Sound pressure level at medium dB(A) air flow Sound pressure level at mini- dB(A) mum air flow 1. Water temperature in coil inlet 7 °C, Water temperature in coil outlet 12 °C, Room air temperature 27 °C b.s. and 19 °C b.u. (according to EN 1397) - maximum speed and head 0 Pa 2.
  • Page 39 TECHNICaL INfoRMaTIoN AirLeaf SL 1000 Models m.u. Sound data Sound pressure level at maxi- dB(A) mum air flow Sound pressure level at medium dB(A) air flow Sound pressure level at mini- dB(A) mum air flow Product dimensions and weight Width 1137 1337 1537...
  • Page 40 TECHNICaL INfoRMaTIoN AirLeaf RS 1000 Models m.u. Medium air flow m³/h Minimum flow rate m³/h Static pressure available Electrical data Power supply V/ph/Hz 230/1/50 Maximum absorbed current 0,11 0,16 0,18 0,26 0,28 Power consumption at the minimum speed Sound data Sound pressure level at maxi- dB(A) mum air flow...
  • Page 41 TECHNICaL INfoRMaTIoN 713 Technical data AirLeaf SLS AirLeaf SLS 1000 Models m.u. Cooling performances (W 7/12 °C; A 27 °C) (1) Total cooling capacity 0,51 1,21 1,62 2,12 2,60 Sensible cooling capacity 0,43 1,01 1,43 1,89 2,19 Water flow 88,00 208,00 279,00 365,00...
  • Page 42: Operating Limits

    TECHNICaL INfoRMaTIoN 72 Operating limits Operating limits Heating Cooling Minimum water inlet temperature °C Maximum water inlet temperature °C Minimum room air temperature °C Maximum room air temperature °C Maximum water-side pressure 1000 1000 73 Dimensions 731 AirLeaf SL, RS front view Lateral view SL 4 pipes...
  • Page 43: Airleaf Sls

    TECHNICaL INfoRMaTIoN 732 AirLeaf SLS front view Lateral view 1000 Models m.u. Product dimensions and weight Width 1135 1335 1535 Height Total depth Net weigth 12,0 14,0 16,0 19,0 23,0...
  • Page 44: Airleaf Sl 2 Pipes Version And Airleaf Rs

    TECHNICaL INfoRMaTIoN 74 Installation template The units are supplied with a paper template for mark- The template is unique for all sizes. for some sizes it is ing the holes necessary for installation. necessary to cut the template following the instructions within it.
  • Page 45: Airleaf Sl 4 Pipes Version

    TECHNICaL INfoRMaTIoN 742 AirLeaf SL 4 pipes version External perimeter of the machine Hole ø8 for horizontal dowel Holes ø8 for dowels External perimeter of the machine Reference H for the assembly instructions of the hydraulic kits Space for pipe passage Electrical box Electrical box for hydraulic connections on the right...
  • Page 46: Airleaf Sls

    TECHNICaL INfoRMaTIoN 743 AirLeaf SLS Holes ø8 for dowels Space for pipe passage for connections on the right Hydraulic connections area on the right wall with flexible pipes Space for pipe passage Condensate drain for hydraulic connections on the right Electrical connection area for hydraulic connections on the right Electrical connection area Condensate drain External perimeter of the machine...
  • Page 47 TECHNICaL INfoRMaTIoN...
  • Page 48 INNoVa S.r.l. Via I Maggio 8 - 38089 Storo (TN) - ITaLY tel. +39.0465.670104 – fax +39.0465.674965 info@innovaenergie.com...