ZURN AquaSense ZER-SM Series Installation, Operation, Maintenance And Parts Manual

Automatic battery-powered flush valve

Advertisement

ZER6000-SM
All goods sold hereunder are warranted to be free from defects in material and factory workmanship for a period of three years from the date of
purchase. Decorative finishes warranted for one year. We will replace at no costs goods that prove defective provided we are notified in writing of
such defect and the goods are returned to us prepaid at Sanford, NC, with evidence that they have been properly maintained and used in accordance
with instructions. We shall not be responsible for any labor charges or any loss, injury or damages whatsoever, including incidental or consequential
damages. The sole and exclusive remedy shall be limited to the replacement of the defective goods. Before installation and use, the purchaser shall
determine the suitability of the product for his intended use and the purchaser assumes all risk and liability whatever in connection therewith. Where
permitted by law, the implied warranty of merchantability is expressly excluded. If the products sold hereunder are "consumer products," the implied
warranty of merchantability is limited to a period of three years and shall be limited solely to the replacement of the defective goods. All weights stated
in our catalogs and lists are approximate and are not guaranteed.
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
!
ADVERTENCIA: Cáncer y Daño Reproductivo - www.P65Warnings.ca.gov
!
AVERTISSEMENT: Cancer et effet nocif sur la reproduction - www.P65Warnings.ca.gov
!
Rev. A | Date: 02/07/23 | C.N. No. 145085 | Prod./Dwg. No. FV828
Patent zurn.com/patents
US 1.855.ONE.ZURN CANADA 1.877.892.5216
ZURN.COM
AquaSense
ZER-SM Series
Automatic Battery-Powered
Flush Valve
Installation, Operation, Maintenance
and Parts Manual
ZER6003-SM
LIMITED WARRANTY
®
ZER6200-SM
ZER6203-SM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AquaSense ZER-SM Series and is the answer not in the manual?

Questions and answers

Summary of Contents for ZURN AquaSense ZER-SM Series

  • Page 1 WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov ADVERTENCIA: Cáncer y Daño Reproductivo - www.P65Warnings.ca.gov AVERTISSEMENT: Cancer et effet nocif sur la reproduction - www.P65Warnings.ca.gov Rev. A | Date: 02/07/23 | C.N. No. 145085 | Prod./Dwg. No. FV828 Patent zurn.com/patents US 1.855.ONE.ZURN CANADA 1.877.892.5216 ZURN.COM...
  • Page 2 This Page Intentionally Left Blank...
  • Page 3: Specifications

    35°F to 104°F [2°C to 40°C] Important Safety Information • Do not convert or modify this Zurn product. All warranties will be voided. • All plumbing is to be installed in accordance with applicable codes and regulations. • Water supply lines must be sized to provide an adequate volume of water for each fixture.
  • Page 4: Package Contents

    Package Contents Control Stop with Vandal Cap Diaphragm Metro ZER-SM Actuator (Optional with Aqua Flush) Valve Body Valve Body Sweat solder Connection with Cast Wall Flange ZERK-SM Hex Wrench Wrench Flush Connection Flush Connection for Urinal for Water Closet Required Tools Optional Accessories Smooth-Jawed Magic Magnet...
  • Page 5 Sweat Solder Adapter Installation Instructions NOTE: Before installation, turn off water supplies to existing fixture and remove flushometer if replacing an existing device. 1. Measure distance from finished wall to the center line of the fixture 2. Slide threaded sweat solder adapter onto water supply pipe until spud.
  • Page 6 Flush Valve Installation Instructions Prior to attaching flush valve tailpiece to control stop, inspect and Control Stop verify that the O-ring seal is located within the O-ring groove at the tailpiece. Ensure that the locking nut and locking snap ring O-Ring Groove are also present on the tailpiece.
  • Page 7 EZ Flush Activation Instruction Using supplied hex wrench,remove battery compartment from the EZ Flush™ unit. Load batteries into compartment tray and reinstall battery tray into the EZ Flush unit. See position of batteries on the left. installed incorrectly, valve will not work and LED will blink once every 5 seconds.
  • Page 8 Maintaining Your EZ Flush Before the supply water is turned on, be sure all stop valves to the flush valves are closed off tight. The stop valves can be opened and closed by using the adjusting screw located at the center of the stop valve cap, behind the stop valve cover if already installed.
  • Page 9 1. While standing next to (not directly in front of) the unit, hold a large and flat, nonreflective object (e.g. white sheet of paper) in front of lens at desired calibration distance (12”-60”). 2. Hold a Zurn Magic Magnet at the position shown below and observe the LED light for up 5 seconds and begin to blink once every half a second.
  • Page 10 ZER-SM Series Parts Breakdown FV828 Rev. A 02/07/23 Page 8...
  • Page 11 Part Identification 1. Seal 16. Vacuum Breaker Tube Nut 31. Piston 2. Collar Gasket 17. Spud Nut 32. Stop Spring 3. Shell & Sensor Module 18. Spud Friction Washer 33. Guide O-Ring 4. Replacement Sensor Lens 19. Spud Sleeve 34. Piston Guide 5.
  • Page 12 Rev. A | Date: 02/07/23 | C.N. No. 145085 | Prod./Dwg. No. FV828 Patent zurn.com/patents US 1.855.ONE.ZURN CANADA 1.877.892.5216 ZURN.COM...

Table of Contents