Download Print this page
ZURN AquaVantage ZH Series Installation, Operation, Maintenance And Parts Manual

ZURN AquaVantage ZH Series Installation, Operation, Maintenance And Parts Manual

Hydraulic-operation closet/urinal systems hydraulic-operation flush valve

Advertisement

Quick Links

Hydraulic-Operation
Closet/Urinal Systems
ZH6000AV
ZH6001AV
ZH6003AV
ZH6010AV
ZH6017AV
ZH6140AV
NOTICE: READ ENTIRE MANUAL PRIOR TO INSTALLING PRODUCT.
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
ADVERTENCIA: Cáncer y daño reproductivo - www.P65Warnings.ca.gov
AVERTISSEMENT: Cancer et effets néfastes sur la reproduction - www.P65Warnings.ca.gov
All goods sold hereunder are warranted to be free from defects in material and factory workmanship for a period of three years from the
date of purchase. Decorative finishes warranted for one year. We will replace at no costs goods that prove defective provided we are
notified in writing of such defect and the goods are returned to us prepaid at Sanford, NC, with evidence that they have been properly
maintained and used in accordance with instructions. We shall not be responsible for any labor charges or any loss, injury or damages
whatsoever, including incidental or consequential damages. The sole and exclusive remedy shall be limited to the replacement of
the defective goods. Before installation and use, the purchaser shall determine the suitability of the product for his intended use
and the purchaser assume all risk and liability whatever in connection therewith. Where permitted by law, the implied warranty of
merchantability is expressly excluded. If the products sold hereunder are "consumer products," the implied warranty of merchantability
is limited to a period of three years and shall be limited solely to the replacement of the defective goods. All weights stated in our
catalogs and listed are approximate and are not guaranteed.
NOTE: The information in this manual is subject to change at any time without notice. Installations may
be performed at different times of construction by different individuals. For this reason, these instructions
should be left on-site with the facility or maintenance manager.
Zurn Industries, LLC
511 W. Freshwater Way, Milwaukee, WI U.S.A. 53204 · Ph. 1-855-ONE-ZURN, Fax 919-775-3541
In Canada
|
Zurn Industries Limited
7900 Goreway Drive Unit 10, Brampton, Ontario L6T5W6 · Ph. 905-405-8272, Fax 905-405-1292
www.zurn.com
ZH6003AV
ZH6142AV
ZH6150AV
ZH6152AV
ZH6190AV
ZH6195AV
LIMITED WARRANTY
AquaVantage
ZH Series
Hydraulic-Operation Flush Valve
Installation, Operation, Maintenance
and Parts Manual
Patented and Patents Pending
ZH6152AV
Rev.
B
Date:
10/30/2018
C.N. No.
Prod. | Dwg. No.
®
SAN008373
FV241

Advertisement

loading
Need help?

Need help?

Do you have a question about the AquaVantage ZH Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ZURN AquaVantage ZH Series

  • Page 1 For this reason, these instructions should be left on-site with the facility or maintenance manager. Zurn Industries, LLC Rev. 511 W. Freshwater Way, Milwaukee, WI U.S.A. 53204 · Ph. 1-855-ONE-ZURN, Fax 919-775-3541 Date: 10/30/2018 In Canada Zurn Industries Limited C.N.
  • Page 2 ‘AV’ ZH Series ® FLOW OPTIONS Exposed/Concealed Flush Valve – Exposed/concealed,quiet diaphragm- Closets type,chrome plated/rough brass, flushometer valve with Zurn’s AquaVantage -WS1 1.6 Gal. Low Consumption Flush TPE, chloramine resistant, dual seal diaphragm with surface optimization and 4.5 Gal. Full Flush clog resistant dynamic orifice.
  • Page 3 25 psi flow pressure. Rough-in for plumbing and double gang box per specification sheet and Figure A. When installing your quality Zurn valve it is recommended that to protect the polished finishyou do not use a toothed wrench. This will cause gouges and scratches on your valve.
  • Page 4 Note: For sweat solder applications,see recommended instructions on Page 3 or refer to those included in the Zurn sweat solder kit. STEP 2 Install Vacuum Breaker Flush Connection (Figure 2) Top Spud –...
  • Page 5 AquaVantage Valve Installation Instructions for Exposed ZH Series ® STEP 4 Install push button actuator. STEP 5 Flush out supply line (Figure 6). Make sure the control stop is closed. Remove flushometer cover. Lift out the diaphragm kit assembly. Install the flushometer cover, wrench tight and open stop. Turn on water supply to flush line of any debris or sediment.
  • Page 6 AquaVantage Repair Kits ® Part Identification 1.Chrome Cover Plate 2. Return Cover Tube 3. Supply Cover Tube 4. Cover Tube Ring with Setscrew 5. Cover Tube Ring with Setscrew 6. Handle Nut 7. Hydraulic Plunger Assembly 8. 1/16” Compression Fitting 9.
  • Page 7 AquaVantage Trouble Shooting Guide ® Problem Cause* Corrective Action* Valve will not operate. 1. Water supply is shut off. 1. Turn on water supply/stop valve. 2. Internal valve filter is plugged. 2. Clean or replace filter. 3. Tubing is hooked up improperly. 3.
  • Page 8 ZURN INDUSTRIES, LLC COMMERCIAL BRASS OPERATION, 5900 ELWIN BUCHANAN DRIVE, SANFORD, NC, U.S.A. 27330 PHONE: 1-800-997-3876 FAX: 919/775-3541 www.zurn.com ZURN INDUSTRIES LIMITED 3544 NASHUA DRIVE, MISSISSAUGA, ONTARIO L4V 1L2 PHONE: 905/405-8272 FAX: 905/405-1292 FV241 Rev. A 10/30/18 Page 8...

This manual is also suitable for:

Aquavantage zh6003avAquavantage zh6010avAquavantage zh6000avAquavantage zh6017avAquavantage zh6001avAquavantage zh6140av ... Show all