Page 1
ADVANCE Split Ducted Unit Installation and Commissioning Guide - Indoor Model Numbers EVV140S EVV160S EVV180S EVV210S EVV240S IMPORTANT NOTE: Please read this manual carefully before installing or operating your air conditioning unit.
Split Ducted Indoor Units Installation and Commissioning Guide Table of Contents 01. Introduction ...........................3 01.01. Information About This Guide 01.02. Product Inspections 01.03. Codes, Regulations And Standards 01.04. Important Safety Symbols And Labels 02. Safety Instructions .........................4 03. Components Overview ........................5 03.01.
Check your air conditioning unit and all items against the invoice upon receiving your shipment. Inspect the unit, components and accessories for any sign of damage. If there is any damage to the unit, contact ActronAir Customer Care Department immediately on: 1300 522 722 to obtain a Goods Return Number.
Split Ducted Indoor Units Installation and Commissioning Guide 02. Safety Instructions • Only licensed HVAC technicians* should install and service this air conditioning equipment. Improper service or alteration by an unqualified technician could result in significant and major damage to the product or property which may render your warranty null and void.
Split Ducted Indoor Units Installation and Commissioning Guide 03. Components Overview 03.01. Indoor Unit Components Overview INDOOR UNIT EC MOTOR ID COIL ID FAN ELECTRICAL BOX COVER INDOOR CONTROL PANEL 03.02. Indoor Unit Electrical Panel Overview EMC FILTER TRANSFORMER (for some models) INDOOR UNIT CONTROL BOARD Installation and Commissioning Guide - Split Ducted Indoor Unit...
3. Minimum Service Access Areas and Spaces for HEIGHT CLEARANCE = 340mm Airflow Clearances are responsibilities of the installer, ActronAir will not be held liable for any extra charges incurred due to lack of access and space for airflow. Installation and Commissioning Guide - Split Ducted Indoor Unit...
3. Minimum Service Access Areas and Spaces for HEIGHT CLEARANCE = 410mm Airflow Clearances are responsibilities of the installer, ActronAir will not be held liable for any extra charges incurred due to lack of access and space for airflow. Installation and Commissioning Guide - Split Ducted Indoor Unit...
3. Minimum Service Access Areas and Spaces for HEIGHT CLEARANCE = 410mm Airflow Clearances are responsibilities of the installer, ActronAir will not be held liable for any extra charges incurred due to lack of access and space for airflow. Installation and Commissioning Guide - Split Ducted Indoor Unit...
TOP VIEW HEIGHT CLEARANCE = 340mm Airflow Clearances are responsibilities of the installer, ActronAir will not be held liable for any extra charges incurred due to lack of access and space for airflow. Installation and Commissioning Guide - Split Ducted Indoor Unit...
Page 10
TOP VIEW HEIGHT CLEARANCE = 410mm Airflow Clearances are responsibilities of the installer, ActronAir will not be held liable for any extra charges incurred due to lack of access and space for airflow. Installation and Commissioning Guide - Split Ducted Indoor Unit...
Page 11
HEIGHT CLEARANCE = 410mm Airflow Clearances are responsibilities of the TOP VIEW installer, ActronAir will not be held liable for any extra charges incurred due to lack of access and space for airflow. Installation and Commissioning Guide - Split Ducted Indoor Unit...
3. Minimum Service Access Areas and Spaces for TOP VIEW Airflow Clearances are responsibilities of the installer, ActronAir will not be held liable for any extra charges incurred due to lack of access and space for airflow. Installation and Commissioning Guide - Split Ducted Indoor Unit...
Page 13
3. Minimum Service Access Areas and Spaces for TOP VIEW Airflow Clearances are responsibilities of the installer, ActronAir will not be held liable for any extra charges incurred due to lack of access and space for airflow. Installation and Commissioning Guide - Split Ducted Indoor Unit...
Compliance and consultation with the authorities having jurisdiction with the installation of this equipment is the responsibility of the installer. ActronAir will not be held liable for any damages or costs as a result of the installer’s failure to comply. Please refer to the matching outdoor unit Installation and Commissioning Guide for further information and details.
Page 15
Split Fan Coil System (Optional) The ActronAir innovative 2-piece fan coil system provides a solution to your difficult and tight roof space installation requirement. This versatile system has a separate fan and coil sections. Each of the compact and lightweight section is simply installed in two separate locations and joined by flexible duct system.
Split Ducted Indoor Units Installation and Commissioning Guide 07. Unit Lifting Procedures 07.01. Crane Lifting Method WARNING WH&S regulations must be observed and will take precedence during lifting process. DANGER Make sure rigging equipment, accessories and plant are sufficiently and safely capable to lift the unit in order to prevent potential damage to property, severe personal injury or death.
Split Ducted Indoor Units Installation and Commissioning Guide 07.02. Fork Lift Method FIGURE 2 INSERT FORKLIFT TINES HERE ELECTRICAL PANEL END INSERT FORKLIFT TINES HERE CAUTION DO NOT LIFT UNIT from this end in order to prevent damage to electrical panel and pipes. Procedure: 1.
Split Ducted Indoor Units Installation and Commissioning Guide 08. Safety Drain Tray NOTES CONDENSATE AND SAFETY TRAY DRAINAGE • Refer to indoor unit dimension page for specification of drain connectors. • Test condensate drain installation to ensure that water flows freely and does not leak. Also check that the drain tray does REVISION DATE DRAWING NUMBER 05 - 05 - 2010...
(positions that range from 9 o’clock to 3 o’clock), as shown below: It is also recommended that only ActronAir 24V zones be connected to this system using RJ45 cable connections. Warranty may be void if third party zones cause damage to the system.
Split Ducted Indoor Units Installation and Commissioning Guide 10. Electrical Installation All electrical work must be carried out by a qualified technician. Make sure all wiring is in accordance with local wiring rules. Wiring connections should be made in accordance with the wiring diagram provided. DANGER Live Electrical Supply ! •...
Split Ducted Indoor Units Installation and Commissioning Guide 11. Indoor Unit Wiring Diagram Variation Code: Variation: Base VARIOUS Model No: Description: INDOOR BOARD + 8 ZONE WITH 3 WALL CONTROLLERS Drawn: Date: 08-05-2019 Drawing No: Revision Size: WD2210 This drawing remains the intellectual property of Actron Engineering Pty Ltd. Date: 02-06-2020 Approved:...
Split Ducted Indoor Units Installation and Commissioning Guide 12. Split Unit Electrical Connection NOTE To minimise noise interference, Data and Power cable clearance should be maintained as much as possible. DETAILED WIRING DIAGRAM IS PROVIDED WITH THE UNIT. Outdoor Unit: Located at the back of electrical/compressor access panel. Indoor Unit: Located at the back of electrical box cover.
Page 23
Split Ducted Indoor Units Installation and Commissioning Guide 2 Core Twisted Data Cable Shielding Instructions (ActronAir Part Number: AEDC2) NOTES • Maintain the twist of the core wires up to the Green Terminal Plug. • Maximum strip length of outer insulation to the Green Terminal Plug is 50mm.
Split Ducted Indoor Units Installation and Commissioning Guide 13.02. Wiring Configuration : Recommended LR7-1 INDOOR UNIT WALL CONTROLLER WALL CONTROLLER WALL CONTROLLER (OPTIONAL) (OPTIONAL) (OPTIONAL) 3570-043 LM-RS-2 OUTDOOR UNIT (OPTIONAL) DATA CONTROL AERSS CABLE (OPTIONAL) MEPS MODEL C ERT I FI ED R-410A LIVE ELECTRICAL WITHIN ENCLOSURE ISOLATE ELECTRICAL SUPPLY BEFORE REMOVING PANELS...
Split Ducted Indoor Units Installation and Commissioning Guide 13.03. Wiring Configuration : Alternate NOTES • Diagram shown below is a general representation only. Refer to individual unit wiring diagram for complete wiring connection details. • Long runs beside Mains cables or TV antenna cables should be avoided where possible. •...
1 to 4 (Optional 4 Zones Piggy-Back Configuration), if 1 to 3 is 75m, then 3 to 4 must be 25m to make a total of 100m. *** Recommended maximum cable length, providing total of preceding cable connections are only 5m. ^ Total Cumulative length of all the aggregate cable must not exceed 500 meters. Consult ActronAir for longer cable length requirement.
Split Ducted Indoor Units Installation and Commissioning Guide 16. Indoor Commissioning Guide Before activating the self-learn mode, ensure the following: 1. System should be in the OFF mode. 2. Ensure all connected zones are able to be turned on. If a connected zone cannot be opened, refer to Troubleshooting guide for more information.
Page 31
Split Ducted Indoor Units Installation and Commissioning Guide Case 2: Multi zone system (Only zones motors no common zones) • Only detected zones should appear to be ON, in Wall Controller Menu 14. • Last Zone Protection will be enabled for zone 1 only (unless changed from the Wall Controller). •...
Split Ducted Indoor Units Installation and Commissioning Guide 18. Maintenance Frequency Checklist Regular servicing of equipment by a qualified technician is recommended every 12 months for residential applications and every quarter for commercial applications. Regular servicing of your unit helps in maintaining its optimum performance and reliability.
Split Ducted Indoor Units Installation and Commissioning Guide 19. Key Parts List PART ITEM DESCRIPTION EVV140S EVV160S EVV180S EVV210S EVV240S NUMBER 2520-338 EC ID Fan 2520-334 2520-313 4540-084 4540-090 Coil Piston 4540-100 4540-128 ID Control Board 2020-169 Filter Board 4080-013 1040-156 1040-254 Indoor Coil...
Need help?
Do you have a question about the ADVANCE EVV140S and is the answer not in the manual?
Questions and answers