ActronAir ADVANCE EVV140S Installation And Commissioning Manual

ActronAir ADVANCE EVV140S Installation And Commissioning Manual

Split ducted unit
Hide thumbs Also See for ADVANCE EVV140S:

Advertisement

Quick Links

ADVANCE
Split Ducted Unit
Installation and Commissioning Guide - Indoor
Model Numbers
EVV140S
EVV160S
EVV180S
EVV210S
EVV240S
IMPORTANT NOTE:
Please read this manual carefully before installing or operating your air conditioning unit.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ADVANCE EVV140S and is the answer not in the manual?

Questions and answers

Summary of Contents for ActronAir ADVANCE EVV140S

  • Page 1 ADVANCE Split Ducted Unit Installation and Commissioning Guide - Indoor Model Numbers EVV140S EVV160S EVV180S EVV210S EVV240S IMPORTANT NOTE: Please read this manual carefully before installing or operating your air conditioning unit.
  • Page 2: Table Of Contents

    Split Ducted Indoor Units Installation and Commissioning Guide Table of Contents 01. Introduction ...........................3 01.01. Information About This Guide 01.02. Product Inspections 01.03. Codes, Regulations And Standards 01.04. Important Safety Symbols And Labels 02. Safety Instructions .........................4 03. Components Overview ........................5 03.01.
  • Page 3: Introduction

    Check your air conditioning unit and all items against the invoice upon receiving your shipment. Inspect the unit, components and accessories for any sign of damage. If there is any damage to the unit, contact ActronAir Customer Care Department immediately on: 1300 522 722 to obtain a Goods Return Number.
  • Page 4: Safety Instructions

    Split Ducted Indoor Units Installation and Commissioning Guide 02. Safety Instructions • Only licensed HVAC technicians* should install and service this air conditioning equipment. Improper service or alteration by an unqualified technician could result in significant and major damage to the product or property which may render your warranty null and void.
  • Page 5: Components Overview

    Split Ducted Indoor Units Installation and Commissioning Guide 03. Components Overview 03.01. Indoor Unit Components Overview INDOOR UNIT EC MOTOR ID COIL ID FAN ELECTRICAL BOX COVER INDOOR CONTROL PANEL 03.02. Indoor Unit Electrical Panel Overview EMC FILTER TRANSFORMER (for some models) INDOOR UNIT CONTROL BOARD Installation and Commissioning Guide - Split Ducted Indoor Unit...
  • Page 6: Unit Dimensions And Clearances

    3. Minimum Service Access Areas and Spaces for HEIGHT CLEARANCE = 340mm Airflow Clearances are responsibilities of the installer, ActronAir will not be held liable for any extra charges incurred due to lack of access and space for airflow. Installation and Commissioning Guide - Split Ducted Indoor Unit...
  • Page 7: Evv180S

    3. Minimum Service Access Areas and Spaces for HEIGHT CLEARANCE = 410mm Airflow Clearances are responsibilities of the installer, ActronAir will not be held liable for any extra charges incurred due to lack of access and space for airflow. Installation and Commissioning Guide - Split Ducted Indoor Unit...
  • Page 8: Evv210S/Evv240S

    3. Minimum Service Access Areas and Spaces for HEIGHT CLEARANCE = 410mm Airflow Clearances are responsibilities of the installer, ActronAir will not be held liable for any extra charges incurred due to lack of access and space for airflow. Installation and Commissioning Guide - Split Ducted Indoor Unit...
  • Page 9: Two-Piece Fan Coil

    TOP VIEW HEIGHT CLEARANCE = 340mm Airflow Clearances are responsibilities of the installer, ActronAir will not be held liable for any extra charges incurred due to lack of access and space for airflow. Installation and Commissioning Guide - Split Ducted Indoor Unit...
  • Page 10 TOP VIEW HEIGHT CLEARANCE = 410mm Airflow Clearances are responsibilities of the installer, ActronAir will not be held liable for any extra charges incurred due to lack of access and space for airflow. Installation and Commissioning Guide - Split Ducted Indoor Unit...
  • Page 11 HEIGHT CLEARANCE = 410mm Airflow Clearances are responsibilities of the TOP VIEW installer, ActronAir will not be held liable for any extra charges incurred due to lack of access and space for airflow. Installation and Commissioning Guide - Split Ducted Indoor Unit...
  • Page 12: Fan Section

    3. Minimum Service Access Areas and Spaces for TOP VIEW Airflow Clearances are responsibilities of the installer, ActronAir will not be held liable for any extra charges incurred due to lack of access and space for airflow. Installation and Commissioning Guide - Split Ducted Indoor Unit...
  • Page 13 3. Minimum Service Access Areas and Spaces for TOP VIEW Airflow Clearances are responsibilities of the installer, ActronAir will not be held liable for any extra charges incurred due to lack of access and space for airflow. Installation and Commissioning Guide - Split Ducted Indoor Unit...
  • Page 14: Installation Instructions

    Compliance and consultation with the authorities having jurisdiction with the installation of this equipment is the responsibility of the installer. ActronAir will not be held liable for any damages or costs as a result of the installer’s failure to comply. Please refer to the matching outdoor unit Installation and Commissioning Guide for further information and details.
  • Page 15 Split Fan Coil System (Optional) The ActronAir innovative 2-piece fan coil system provides a solution to your difficult and tight roof space installation requirement. This versatile system has a separate fan and coil sections. Each of the compact and lightweight section is simply installed in two separate locations and joined by flexible duct system.
  • Page 16: Unit Lifting Procedures

    Split Ducted Indoor Units Installation and Commissioning Guide 07. Unit Lifting Procedures 07.01. Crane Lifting Method WARNING WH&S regulations must be observed and will take precedence during lifting process. DANGER Make sure rigging equipment, accessories and plant are sufficiently and safely capable to lift the unit in order to prevent potential damage to property, severe personal injury or death.
  • Page 17: Fork Lift Method

    Split Ducted Indoor Units Installation and Commissioning Guide 07.02. Fork Lift Method FIGURE 2 INSERT FORKLIFT TINES HERE ELECTRICAL PANEL END INSERT FORKLIFT TINES HERE CAUTION DO NOT LIFT UNIT from this end in order to prevent damage to electrical panel and pipes. Procedure: 1.
  • Page 18: Safety Drain Tray

    Split Ducted Indoor Units Installation and Commissioning Guide 08. Safety Drain Tray NOTES CONDENSATE AND SAFETY TRAY DRAINAGE • Refer to indoor unit dimension page for specification of drain connectors. • Test condensate drain installation to ensure that water flows freely and does not leak. Also check that the drain tray does REVISION DATE DRAWING NUMBER 05 - 05 - 2010...
  • Page 19: Zone Barrel Installation Instructions

    (positions that range from 9 o’clock to 3 o’clock), as shown below: It is also recommended that only ActronAir 24V zones be connected to this system using RJ45 cable connections. Warranty may be void if third party zones cause damage to the system.
  • Page 20: Electrical Installation

    Split Ducted Indoor Units Installation and Commissioning Guide 10. Electrical Installation All electrical work must be carried out by a qualified technician. Make sure all wiring is in accordance with local wiring rules. Wiring connections should be made in accordance with the wiring diagram provided. DANGER Live Electrical Supply ! •...
  • Page 21: Indoor Unit Wiring Diagram

    Split Ducted Indoor Units Installation and Commissioning Guide 11. Indoor Unit Wiring Diagram Variation Code: Variation: Base VARIOUS Model No: Description: INDOOR BOARD + 8 ZONE WITH 3 WALL CONTROLLERS Drawn: Date: 08-05-2019 Drawing No: Revision Size: WD2210 This drawing remains the intellectual property of Actron Engineering Pty Ltd. Date: 02-06-2020 Approved:...
  • Page 22: Split Unit Electrical Connection

    Split Ducted Indoor Units Installation and Commissioning Guide 12. Split Unit Electrical Connection NOTE To minimise noise interference, Data and Power cable clearance should be maintained as much as possible. DETAILED WIRING DIAGRAM IS PROVIDED WITH THE UNIT. Outdoor Unit: Located at the back of electrical/compressor access panel. Indoor Unit: Located at the back of electrical box cover.
  • Page 23 Split Ducted Indoor Units Installation and Commissioning Guide 2 Core Twisted Data Cable Shielding Instructions (ActronAir Part Number: AEDC2) NOTES • Maintain the twist of the core wires up to the Green Terminal Plug. • Maximum strip length of outer insulation to the Green Terminal Plug is 50mm.
  • Page 24: Wall Controller Options

    Split Ducted Indoor Units Installation and Commissioning Guide Circuit Breaker Size and Cable Size Requirement Circuit Breaker Size Cable Size (mm²) Amps MAIN O.D. to I.D. Model CRV140S / EVV140S 25.0 CRV160S / EVV160S 32.0 CRV180S / EVV180S 32.0 CRV160T / EVV160S 20.0 CRV180T / EVV180S 20.0...
  • Page 25: Wiring Configuration : Recommended

    Split Ducted Indoor Units Installation and Commissioning Guide 13.02. Wiring Configuration : Recommended LR7-1 INDOOR UNIT WALL CONTROLLER WALL CONTROLLER WALL CONTROLLER (OPTIONAL) (OPTIONAL) (OPTIONAL) 3570-043 LM-RS-2 OUTDOOR UNIT (OPTIONAL) DATA CONTROL AERSS CABLE (OPTIONAL) MEPS MODEL C ERT I FI ED R-410A LIVE ELECTRICAL WITHIN ENCLOSURE ISOLATE ELECTRICAL SUPPLY BEFORE REMOVING PANELS...
  • Page 26: Wiring Configuration : Alternate

    Split Ducted Indoor Units Installation and Commissioning Guide 13.03. Wiring Configuration : Alternate NOTES • Diagram shown below is a general representation only. Refer to individual unit wiring diagram for complete wiring connection details. • Long runs beside Mains cables or TV antenna cables should be avoided where possible. •...
  • Page 27: Cable Length - Zoning

    1 to 4 (Optional 4 Zones Piggy-Back Configuration), if 1 to 3 is 75m, then 3 to 4 must be 25m to make a total of 100m. *** Recommended maximum cable length, providing total of preceding cable connections are only 5m. ^ Total Cumulative length of all the aggregate cable must not exceed 500 meters. Consult ActronAir for longer cable length requirement.
  • Page 28: Wiring Connections

    Split Ducted Indoor Units Installation and Commissioning Guide 15. Wiring Connections 15.01. LR7-1 AND LC7-2 Wall Control Wiring Connections INDOOR CONTROL WALL CONTROL WIRING BOARD POWER: - BROWN / ORANGE WALL CONTROLLER 485 A: - BLUE +12V A 485 B: - BLUE-WHITE GND: - BROWN-WHITE / ORANGE-WHITE...
  • Page 29: Lm-Rs-2 Optional Sensor Wiring Connections

    Split Ducted Indoor Units Installation and Commissioning Guide 15.03. LM-RS-2 Optional Sensor Wiring Connections REMOTE SENSOR WIRING INDOOR PAIR 1 (BLUE / BLUE-WHITE) CONTROL PAIR 2 (ORANGE / ORANGE-WHITE) REMOTE SENSOR WIRING PAIR 3 (GREEN / GREEN-WHITE) BOARD PAIR 4 (BROWN / BROWN-WHITE) PAIR 1: - BLUE / BLUE-WHITE PAIR 2: - ORANGE / ORANGE-WHITE TEMP...
  • Page 30: Indoor Commissioning Guide

    Split Ducted Indoor Units Installation and Commissioning Guide 16. Indoor Commissioning Guide Before activating the self-learn mode, ensure the following: 1. System should be in the OFF mode. 2. Ensure all connected zones are able to be turned on. If a connected zone cannot be opened, refer to Troubleshooting guide for more information.
  • Page 31 Split Ducted Indoor Units Installation and Commissioning Guide Case 2: Multi zone system (Only zones motors no common zones) • Only detected zones should appear to be ON, in Wall Controller Menu 14. • Last Zone Protection will be enabled for zone 1 only (unless changed from the Wall Controller). •...
  • Page 32: Maintenance Frequency Checklist

    Split Ducted Indoor Units Installation and Commissioning Guide 18. Maintenance Frequency Checklist Regular servicing of equipment by a qualified technician is recommended every 12 months for residential applications and every quarter for commercial applications. Regular servicing of your unit helps in maintaining its optimum performance and reliability.
  • Page 33: Key Parts List

    Split Ducted Indoor Units Installation and Commissioning Guide 19. Key Parts List PART ITEM DESCRIPTION EVV140S EVV160S EVV180S EVV210S EVV240S NUMBER 2520-338 EC ID Fan 2520-334 2520-313 4540-084 4540-090 Coil Piston 4540-100 4540-128 ID Control Board 2020-169 Filter Board 4080-013 1040-156 1040-254 Indoor Coil...
  • Page 34 THIS PAGE WAS INTENTIONALLY LEFT BLANK...
  • Page 35 THIS PAGE WAS INTENTIONALLY LEFT BLANK...
  • Page 36 ©Copyright 2020 Actron Engineering Pty Limited ABN 34 002767240. ®Registered Trade Marks of Actron Engineering Pty Limited. ActronAir is constantly seeking ways to improve the design of its products. Therefore, specifications are subject to change without notice. Document: 0525-084 Ver. 1 Issue Date: 07/2020...