ATTENTION!
![]() | PURITY | 450 | 600 | 1200 |
450 | ![]() | X | X | |
600 | X | ![]() | X | |
1200 | X | X | ![]() |
The PURITY replacement cartridge may only be used in combination with the pressure vessel that has been specifically designed for its size.
The BRITA PURITY Quell ST Water Filter System is used for decarbonisation of drinking water to prevent limescale deposits in downstream appliances. Depending on the by-pass setting, calcium, magnesium and metal ions can be selectively removed from the drinking water during the flow process. Furthermore, the filter material reduces cloudiness and organic impurities, as well as contents which affect taste and odour (e.g. chlorine residues) in the filtrate and bypass water. By-pass settings on the connector head are used to set the total hardness reduction to the local water hardness or the requirements of the application in order to achieve an optimum water quality. The filter systems are available in 3 different filter system sizes (PURITY 450, PURITY 600 and PURITY 1200) and each in the version without integrated measuring and display electronics or with measuring and display (Advanced Control System, ACS-Technology) electronics.
Filter systems with ACS Technology show you the current remaining capacity and bypass setting of your filter cartridge, the set type and size of the filter system and the last replacement date of the filter cartridge. This ensures optimum filter control and water filtrate quality. Further information on the filter system with ACS Technology.
The unique IntelliBypass ensures a constant by-pass proportion over the entire usage periods, irrespective of the volumetric flow of the terminal device concerned. The result is a consistently high water quality specifically tailored to the application-specific requirements and the local water conditions.
Typical applications for BRITA PURITY Quell ST water filter systems are coffee and espresso machines, hot and cold drinks vending machines as well as steam ovens (combi ovens) and air humidifiers.
The filter system is designed for limited spaces, especially in drinks machines and kitchen installations and can be operated horizontally and vertically.
The food quality of BRITA water filter products has been inspected and confirmed by an independent institute.
Adhere to the ambient conditions in the Technical Data for storage and transport.
The manual should be seen as part of the product and kept for the whole service life of the filter system and passed on to subsequent owners.
Installation, filter replacement and maintenance of the filter system may be carried out only by specialist staff.
The product can only operated perfectly and safely if it is installed, used and serviced in the manner described in this manual.
Only solution-specific BRITA filter cartridges may be used for the applications listed.
Installation must be performed precisely in accordance with the instructions in this manual. BRITA shall not be held liable for any damage, including subsequent damage, arising from the incorrect installation or use of the product.
Filter system | x* flush quantity after 2–3 days stagnation | x** flush quantity after 4 weeks stagnation |
PURITY 450 | 6 litres | 30 litres |
PURITY 600 | 12 litres | 60 litres |
PURITY 1200 | 24 litres | 120 litres |
Production code sticker filter cartridge and box, example: 1000231 D 19120020010 | ||
1000231 | Article number | ![]() |
D | Production site (Deutschland/Germany) | |
19 | Production year, here: 2019 | |
12 | Production week, here: calendar week 12 | |
002 | Batch No. of filter medium, here the second batch filled in terms of quantity | |
0010 | Serial number of the filter cartridge, here the tenth cartridge from the second batch | |
Production code sticker Display Unit (optional) - Example: 1011208E919319008764 | ||
1011208 | BRITA identification number | ![]() |
E | Supplier ID | |
9 | Production year, here: 2019 | |
19 | Production week, here: calendar week 19 | |
3 | Production day from Monday (1) to Friday (5), here: Wednesday | |
19 | Production year, here: 2019 | |
008764 | Serial identification number | |
Production date of pressure vessel and pressure vessel lid, example: 0319 | ||
03 | Production month, here: March | ![]() |
19 | Production year, here: 2019 |
Prior to installation, read the Technical Data and the Operating and Safety Information. After the product has been stored and transported at temperatures below 0°C, it must be stored with the original packaging open for at least 24 hours before commissioning.
To install a PURITY Quell new filter, you need a pressure vessel , filter cartridge
and pressure vessel lid
.
Before installing, remove everything included in the delivery from the packaging and check that everything is present:
1 x Pressure Vessel
1 x Pressure Vessel Lid
1 x Filter Cartridge
1 x Manual
1 x Carbonate hardness test or total hardness test
If anything is missing, please contact your local BRITA Office.
Note: The inlet and outlet hoses are not included in the standard scope of delivery. The use of BRITA hose sets is recommended.
The max. tightening torque at the 1" and 3/4" connections must not exceed 15 Nm! Only hose connections with flat seals may be used. Hoses with conical screwed connections damage the filter head connections and invalidate any guarantee claims. Only hoses that comply with DVGW-W 543 may be used to connect the device.
Before assembly, note the direction of flow on the upper side of the filter head, "IN" = water inlet, "OUT" = water outlet. Prior to installation, note installation dimensions and operating position. If no original hoses are used, the 1"–3/4" adapter supplied must be used to ensure the return valve is sealed correctly (pre-fitted in the water inlet).
Representation in operating mode
Carbonate hardness
The units of carbonate hardness or total hardness can be set as required to German °dH (= display setting °KH, °DH), English (°e = Clark) (= display setting °EH), French (°f) (= display setting °FH), American (grains per gallon) (= display setting gpg) or international hardness values (mg/l CaCO3) (= display setting mg/L).
If the setting for the type of hardness (= unit) is changed while the filter is operating, the values that were set originally are converted automatically.
Bar chart
Representation of the remaining capacity using bar charts. After installation of a new filter system or after a filter change, the symbolised filter cartridge is completely filled with 10 bars.
Bypass proportion in percentage
The by-pass proportion is defined as the proportion of decarbonised water in the total amount of filtrate and is indicated as a percentage.
Flow symbol
When water is removed via the filter system, a graphic wave is shown on the display.
Available remaining capacity of the filter cartridge
The remaining capacity of the filter cartridge is shown in litres or in US gallons, depending on which has been selected.
When water is removed, it counts backwards in 1 litre or 1 US gallon stages. If the cartridge is already exhausted, the capacity is indicated as being negative by flashing.
With a remaining capacity of 20% the last two bars in the bar chart start to flash.
With a remaining capacity of 10% the last bar in the bar chart flashes with the two change arrows. From a remaining capacity of 0% the negative bars and the change arrows flash alternately with the remaining capacity shown in negative.
If the monthly limit has been reached up to a month before expiry of the set time limit, it is signalled by the date field flashing.
If the monthly limit is 100% reached, it is signalled by alternate flashing of the date field and the change arrows.
If the remaining capacity and the monthly limit are exceeded, the negative remaining capacity and the date field flash alternately with the change arrows.
Date of the filter commissioning or last filter cartridge change
The date of filter commissioning or last filter cartridge change is indicated as follows:
Example: 28/10/09 | |
28 | Day, here the 28th day |
10 | Month, here October |
09 | Year, here 2009 |
Selecting the units of measurement
You can choose between European, American and international units of measurement on the display.
For European units of measurement: depending on the type of filter system (STD, STM), select the specified unit of measurement for water hardness °KH, °EH, °FH or ° DH. The unit of v olume and date format are then automatically displayed in litres and DD/MM/YY respectively.
For American units of measurement, select gpg (unit of measurement for water hardness); the unit of volume and the date format are then automatically displayed in US gallons and MM/DD/YY respectively.
For international units of measurement, select mg/L (unit of measurement for water hardness); the unit of volume and the date format are then automatically displayed in litres and DD/MM/YY respectively.
Parameterisation
The following parameters have to be entered:
Monthly limit 2–12
Operating the display unit
To operate the display unit, it must be removed from the connecting fittings. Slide the display housing up approx. 10 mm and pull off the display unit. The display unit is operated using a button on the back of the display unit. The display unit is supplied in standby mode. To activate the display, press the button on the back once briefly and then reset after inputting the parameters.
Parameter input water hardness and filter system size
At this level, parameters needed for operation are set manually. The type and size of filter system is selected, the unit of hardness is set, the local carbonate hardness or total hardness of the tap water is entered, and the maximum cartridge service life (monthly limit) is activated. After this the parameters must be accepted.
The set parameters can now be accepted. If you want to accept the parameters, proceed as follows:
The set parameters have been accepted.
Note: If no input is made within 30 seconds, the display will return to standby or operating mode without accepting amended parameters.
Determining the by-pass setting
The by-pass setting is identified according to the application and the carbonate hardness or total hardness identified on the basis of the bypass and capacity table. The by-pass is then set on the by-pass screw as follows:
Turn the by-pass screw until the desired by-pass (0–50%) agrees with the marking.
Use Allen key 6mm or 7/32".
Never overwind the by-pass screw to avoid any damage.
Note: A 10 litre bucket is required for flushing/draining.
The PURITY replacement cartridge may only be used in combination with the pressure vessel that has been specifically designed for its size. See cover.
During the exchange, carefully examine all dismantled parts! Faulty parts must be exchanged and dirty parts should be cleaned. Read the Operating and Safety Information prior to replacement. After the product has been stored and transported at temperatures below 0°C, it must be stored with the original packaging open for at least 24 hours before commissioning at the ambient temperatures.
Filter systems without a measuring and display unit
The filter cartridge must be replaced after 6–12 months, at the latest 12 months after commissioning, irrespective of the level of exhaustion of the filter system. If the capacity of the filter cartridge has already been exhausted, it must be exchanged e arlier.
Filter systems with a measuring and display unit
The filter cartridge must be replaced no later than 12 months after commissioning, irrespective of the level of exhaustion of the filter system. If the capacity of the filter cartridge has already been exhausted, it must be replaced earlier.
If the cartridge is already exhausted, the capacity is indicated as being negative by flashing. No bars are shown in the display.
If the monthly limit for the cartridge has been exceeded, this is indicated by the date flashing.
Resetting the display unit
To operate the display unit it has to be removed from the connecting fittings. Slide the display housing up approx. 10 mm and pull off the display unit to the front. The display unit is operated using a button on the back of the display unit.
Note: This automatically sets the monthly limit to 12 months.
Note: If no input is made within 30 seconds, the display will return to operating mode without accepting amended parameters.
Insert display unit from front at a height of approx. 10 mm and slide down. The loops on the display part must be inserted in the grooves on the measuring head.
By-pass and capacity table for combi ovens and conventional ovens
Depending on machine type, select by-pass setting 10% to achieve optimally treated water for the combi oven/conventional oven. We will be happy to make specific recommendations.
Note: The capacity limits refer to average utilisation of the terminal equipment, do not contain any filter flushing and cleaning cycles and depend on local water quality, flow, mains pressure and flow continuity.
Regularly check the filter system for leaks. Regularly check the hoses for kinks. Bent hoses must be replaced.
The complete filter system must be replaced in rotation after a maximum of ten years.
The hoses must be replaced in rotation after a maximum of five years.
Prior to changing, read the Technical Data and the Operating and Safety Information.
Regularly clean the outside of the filter system with a soft, damp cloth.
Do not use any substances incompatible with the material or abrasive cleaning materials.
The following data can be queried in the query mode:
Production data
Production year: Example 08 = 2008
Device number: consecutive
Battery useful life: Example 31/12/19 = The battery in the display unit will be exhausted on 31/12/19 and the complete filter system has reached its max. usage period.
Total volume meter
The total volume meter is managed at this level; it counts up from 0 irrespective of the cartridge change.
Memory Call-Up
In the Memory Call-Up mode, the data of the last 4 filter cartridges used can be called up.
At the top left, the indicator for the filter cartridge (-1 for previous filter cartridge) is displayed alternately with the carbonate hardness set and the hardness unit. At the top right, the filter system size is displayed alternately with the by-pass setting (display 1 s indicator, 1 s carbonate hardness), at the bottom left, the meter reading when changing the cartridge (-1) and at the bottom right, the installation date of the cartridge.
Meaning: the filter cartridge most recently used was a PURITY 1200 cartridge, the filter cartridge was inserted on 25/06/09 and operated up to a meter reading of 23166 litres. The carbonate hardness set was 14°KH and the by-pass measured was 30%.
The same applies to the cartridge(-2), preceding filter cartridge and the other preceding filter cartridges -3, -4.
Error Messages
Error level E1 indicates whether an error has occurred in blend detection.
E1 is activated as soon as the current bypass is not correctly identified. The word Start is then displayed together with the date of occurrence.
As soon as the current bypass setting is identified correctly again, the error has ended and the Stop date is added. At error level 01 the Stop and Start display alternates every s econd.
Error level E2 indicates whether and from when until when an error has occurred at the outlet water meter. Display is similar to level E1.
Cause: Water intake closed.
Troubleshooting: Open water intake on the upstream stop valve or inlet valve on inlet hose
.
Installation and maintenance of the filter system may be carried out only by specialist staff.
No or low water flow in spite of open water intake
Cause: Mains pressure too low.
Troubleshooting: Check mains pressure.
If the fault continues in spite of adequate mains pressure, check the filter system and filter cartridge and change if necessary.
Prior to changing, read the Technical Data and the Operating and Safety Information.
Cause: Screwed connections not fitted correctly.
Troubleshooting: Check mains pressure. Check all screwed connections and mount.
If the fault continues, exchange filter system.
Prior to changing, read the Technical Data and the Operating and Safety Information.
Cause: O-ring at the filter cartridge is not seated correctly.
Troubleshooting: Check correct seat of the O-ring.
Prior to dismantling read the data and the Operating and Safety Information.
Cause: Battery drained.
Troubleshooting: Replace display unit (Order number).
Note: When replacing the display unit, follow the enclosed manual.
Cause: Monthly limit expired or the remaining capacity of the filter cartridge is exhausted.
Troubleshooting: Replace filter cartridge.
Bypass setting in the display does not agree with the setting of the bypass screw
Cause: Filter was not commissioned correctly.
Troubleshooting: F lush filter again. Check data in the display after flushing.
Bypass setting in the display does not agree with the setting of the bypass screw
Cause: Valve strip of the by-pass setting not set correctly.
Troubleshooting: Flush filter system again and readjust bypass screw.
The installed battery is designed for a service life of approx. 10 years. The battery and display unit must not be burnt and must not be disposed of in domestic waste.
To remove the battery, please proceed as follows:
PURITY Quell ST filter system
PURITY 450 Quell ST | PURITY 600 Quell ST | PURITY 1200 Quell ST | |||||
MDU* | without MDU* | MDU* | without MDU* | MDU* | without MDU* | ||
Operating pressure | 2 bar – max. 6.9 bar | ||||||
Operating/water temperature | 4°C to 30°C | ||||||
Ambient temperature during | operation | 10°C to 40°C | |||||
storage | –20°C to 50°C | ||||||
Flow rate with 1 bar pressure loss | 300 l/h | 350 l/h | 300 l/h | 350 l/h | 300 l/h | 350 l/h | |
Empty filter cartridge volume | 3.9 l | 5.8 l | 10.9 l | ||||
Weight (dry/wet) | 10 kg/12 kg | 12 kg/15 kg | 18 kg/24 kg | ||||
Dimensions | 249 mm/222 mm/408 mm | 249 mm/222 mm/520 mm | 288 mm/255 mm/550 mm | ||||
Operating position | Vertically or horizontally | ||||||
Inlet connection | G 1" | ||||||
Outlet connection | G 3/4" |
* Measuring and Display Unit
The PURITY replacement cartridge may only be used in combination with the pressure vessel that has been specifically designed for its size. See cover.
PURITY Quell ST
Article number | Item | |
PURITY 450 Quell ST | ||
PURITY 450 Quell ST (Complete System with Filter Cartridge) with Measuring and Display unit | 1009227 | 1 + 2 + 3 |
PURITY 450 Quell ST (Complete System with Filter Cartridge) | 1009228 | 1 + 2 + 4 |
Filter cartridge | 273000 | 2 |
PURITY 600 Quell ST | ||
PURITY 600 Quell ST (Complete System with Filter Cartridge) with Measuring and Display unit | 1009229 | 1 + 2 + 3 |
PURITY 600 Quell ST (Complete System with Filter Cartridge) | 1009230 | 1 + 2 + 4 |
Filter cartridge | 273200 | 2 |
PURITY 1200 Quell ST | ||
PURITY 1200 Quell ST (Complete System with Filter Cartridge) with Measuring and Display unit | 1009231 | 1 + 2 + 3 |
PURITY 1200 Quell ST (Complete System with Filter Cartridge) | 1009232 | 1 + 2 + 4 |
Filter cartridge | 273400 | 2 |