TROUBLESHOOTING
Problem
Full-time surge protection outlets stop
providing power to equipment. Circuit
Circuit breaker has been tripped due to
breaker button is projecting from the
an overload.
side of the unit.
Battery not fully charged.
The UPS does not perform
expected runtime.
Battery is worn out.
The on/off switch is designed to
prevent damage from rapidly turning
it off and on.
The unit is not connected to an
AC outlet.
The UPS will not turn on.
The battery is worn out.
Mechanical problem.
The frequency is beyond 47-63Hz
The USB cable is not connected.
PowerPanel® Personal is inactive
The USB cable is connected to a bad
(all icons are gray).
USB port.
The unit is not providing battery power.
Additional troubleshooting information can be found at "Support" at www.CyberPowerSystems.com
TECHNICAL SPECIFICATIONS
Model
SL700U
Capacity
700VA / 370W
Nominal Input
Voltage
Input Frequency
On-Battery
Output Voltage
On-Battery
Output Frequency
Max. Load for
700VA / 370W
UPS Outlets
Max. Load for
Full-Time Surge
Protection outlets
On-Battery Output
Wave Form
Operating
Temperature
Operating Relative
Humidity
Size
Width/Height/Depth
Net Weight
(lbs./kg)
Typical Battery
Recharge Time
Typical Battery Life
3 to 6 years, depending on number of discharge/recharge cycles
Recommended
Battery
Safety Approvals
UL1778(UPS), cUL CSA C22.2 No. 107.3-05, FCC/DoC Class B
7
Possible Cause
Solution
Turn the UPS off and unplug at least one
piece of equipment. Reset the circuit
breaker by depressing the button, and
then turn the UPS on.
Recharge the battery by leaving the
UPS plugged in.
Contact CyberPower Systems
about replacement batteries at:
cyberpowersystems.com/support.
Turn the UPS off. Wait 10 seconds and
then turn the UPS on.
The unit must be connected to a
110/120V 50/60Hz outlet.
Contact CyberPower Systems
about replacement batteries at:
cyberpowersystems.com/support.
Contact CyberPower Systems at:
cyberpowersystems.com/support.
Turn the UPS off. Make sure the
frequency range is within 47-63Hz.
Or you can turn on with battery mode.
Connect the USB cable to the UPS unit
and an open USB port on the back of
the computer.
Check for a different USB port and plug
the cable in.
Shutdown your computer and turn the
UPS off. Wait 10 seconds and turn the
UPS back on. This should reset the unit.
SL750U
SL900UC
750VA / 375W
900VA / 450W
120 Vac
50/60 Hz +/- 3 Hz
120Vac +/- 5%
50Hz/60Hz +/- 1% (auto-sensing)
750VA / 375W
900VA / 450W
12 Amps
Simulated Sine Wave
+ 32°F to 104°F / 0°C to 40°C
0 to 95% non-condensing
12.76 x 5.4 x 2.76 in. / 324 x 138 x 70 mm
6.78 lbs. / 3.07 kg
8 hours typical from total discharge
Sealed Maintenance Free Lead Acid Battery
DEFINITIONS FOR LED INDICATORS & AUDIBLE ALARMS
POWER
On
On*
On*
Off
Off
SYSTEM FUNCTION BLOCK DIAGRAM
Input
EMI
Filter
Normal Mode
Battery Mode
CYBERPOWER GREENPOWER UPS™ TECHNOLOGY
Advanced Energy-Saving Design
SL950U
The GreenPower UPS™ has a high-efficiency charger, which makes it
the most energy-efficient UPS in its class. The advanced high-frequency
charging system significantly improves charging efficiency and conserves
950VA / 510W
energy. As a result of this advanced design, the GreenPower UPS™ uses
less energy compared to competitive models. The GreenPower UPS™ is
manufactured in accordance with the Restriction on Hazardous Substances
(RoHS) directive making it one of the most environmentally-friendly UPS
systems on the market today.
FCC COMPLIANCE STATEMENT
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this
device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in
950VA / 510W
a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference
by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the user's
authority to operate the equipment.
Canadian Compliance Statement
CAN ICES-3 (B)/NMB-3(B)
LIMITED WARRANTY AND CONNECTED EQUIPMENT GUARANTEE
Please visit www.CyberPowerSystems.com for a copy of the Limited Warranty and Connected
Equipment Guarantee.
Where Can I Get More Information?
The application of the United Nations Convention of Contracts for the International Sale of
Goods is expressly excluded. CyberPower is the warrantor under this Limited Warranty.
For further information please feel free to contact CyberPower at:
Cyber Power Systems (USA), Inc. 4241 12th Ave E., STE 400, Shakopee, MN 55379;
call us at (877) 297-6937; or submit a web ticket online at cyberpowersystems.com/support.
Cyber Power Systems (USA), Inc. encourages environmentally sound methods for disposal
and recycling of its UPS products. Please dispose and/or recycle your UPS and batteries in
accordance to the local regulations of your state.
WARNING: This product can expose you to chemicals including bisphenol A (BPA) and styrene,
which is known to the State of California to cause reproductive harm and cancer. For more
information, go to www.P65Warnings.ca.gov.
© 2024 CyberPower Systems (USA), Inc. PowerPanel® Personal is a trademark of Cyber Power Systems(USA) Inc.
All rights reserved. All other trademarks are the property of their respective owners.
ALARM
Off
Normal
Beep
Utility Failure - Battery Mode –
twice every
The UPS is providing power to battery power-supplied outlets
30 seconds
from its battery.
Rapid
Utility Failure - Low Battery –
beeping every
The UPS is providing battery power. Rapid beeping indicates
1/2 second
the unit will run out of power soon.
Overload –
Occurs when connected equipment exceeds the rating of battery outlets
Constant tone
of the UPS. Turn the UPS off, unplug at least one piece of equipment
from battery outlets, reset the circuit breaker and turn the unit on.
Utility Failure –
Constant tone
The frequency is beyond 47-63Hz. The UPS will not turn on
in line mode.
* LED will flash when UPS alarm is beeping.
Surge
Suppressor
Charger
AC / DC
6
CONDITION
Output
Inverter
Battery
G
P
UPS
REEN
OWER
Energy-Saving Technology
8
K01-0000740-03