4.2 - Electrical data

BW05 (without hydronic module)
Power circuit
Nominal power supply
Voltage range
Control circuit supply
Maximum unit power input*
Nominal unit current draw**
Maximum unit current draw†
Maximum start-up current (standard
unit without electronic starter)††
Maximum start-up current
(electronic-starter option)‡
Holding current for
three-phase short circuits
*
Power input of the compressor(s) at maximum unit operating conditions: entering/leaving evaporator water temperature = 15°C/10°C, maximum condensing temperature of
65°C, and 400 V nominal voltage.
**
Nominal unit current draw at standard conditions: evaporator entering/leaving water temperature 12°C/7°C, condenser entering/leaving water temperature 30°C/35°C. The
current values are given at 400 V nominal voltage.
*** Nominal unit current draw at standard conditions: evaporator entering/leaving water temperature 12°C/7°C, saturated condensing temperature (dew point) 45°C, subcooling 5
K. The current values are given at 400 V nominal voltage.
Maximum unit operating current at maximum unit power input and 400 V.
†† Maximum instantaneous starting current at 400 V nominal voltage and with compressor in across-the-line start (maximum operating current of the smallest compressor(s) +
locked rotor current of the largest compressor).
Maximum instantaneous starting current at 400 V nominal voltage and with compressor with electronic starter (maximum operating current of the smallest compressor(s) +
reduced start-up current of the largest compressor).
Evaporator hydronic module
BW05
Single pump
Shaft power rating
Power input*
Maximum current draw**
Dual pump
Shaft power rating
Power input
Maximum current draw
Condenser hydronic module
BW05
Variable-speed single pump
Shaft power rating
Power input***
Maximum current draw†
Variable-speed dual-pump
Shaft power rating
Power input
Maximum current draw
Notes
The water pump power input values given are for guidance only.
BW05 units have an evaporator and a condenser pump.
To obtain the maximum unit power input for a unit with hydronic kit add the evaporator (*) and condenser pump (***) power input to the maximum power input of the unit
without hydronic module, given in the top table.
To obtain the maximum unit current draw for a unit with hydronic kit add the evaporator (**) and condenser pump current (†) draw to the maximum current draw of the unit
without hydronic module, given in the top table.
12
020
025
030
040
V-ph-Hz
400-3-50
V
360-440
The control circuit is supplied via the unit-mounted transformer
kW 8.1
10.3
12.0 15.8
A 9. 9
12.6
14.6 17.9
A 13.7 17.6
20.5 25.9
A
86.0
130.0 130.0 135.0 155.0 147.6 155.5 160.9 185.2 245.2 254.0 309.0 318.0 212.6 245.7 314.5 332.0 396.0 414,0
A
51,6
78,0
78,0
81,0
kA
7.5
7.5
7.5
7.5
020
025
030
040
kW
0.75
0.75
0.75
0.75
kW
1.0
1.0
1.0
1.0
A
1.9
1.9
1.9
1.9
kW
-
-
-
-
kW
-
-
-
-
A
-
-
-
-
020
025
030
040
kW
1.85
1.85
1.85
1.85
kW
2.5
2.5
2.5
2.5
A
4.6
4.6
4.6
4.6
kW
-
-
-
-
kW
-
-
-
-
A
-
-
-
-
045
060
070
080
090
110
18.0
22.3
27.8 31.6 36.1
21.1
27.2
32.5 35.8 42.1
30.2
38.0
46.3 52.0 61.0
93,0
95,6 101,5 106,9 123,2 159,2 168,0 201,0 210,0 158,6 183,7 228,5 246,0 288,0 306.0
7.5
10
10
10
10
10
045
060
070
080
090
0.75
1.5
1.5
1.5
1.5
1.0
2.1
2.1
2.1
2.1
1.9
3.9
3.9
3.9
3.9
-
2.2
2.2
2.2
2.2
-
2.8
2.8
2.8
2.8
-
4.7
4.7
4.7
4.7
045
060
070
080
090
1.85
1.85
1.85
1.85
1.85
2.5
2.5
2.5
2.5
2.5
4.6
4.6
4.6
4.6
4.6
-
2.2
2.2
2.2
2.2
-
2.8
2.8
2.8
2.8
-
4.7
4.7
4.7
4.7
120
135
150
160
185
42.4
48.8
54.0
59.1
63.2
72.2 84.9
48,1
54,0
61,0
68,0
71,7
84,2 96,1
69.0
78.0
87.0
96.0
104.0 121.0 139.0 156.0 174.0 192.
10
10
10
18
18
110
120
135
150
160
185
1.85
1.85
1.85
1.85
4
4
2.5
2.5
2.5
2.5
5
5
4.6
4.6
4.6
4.6
8.3
8.3
4
4
4
4
4
4
5.3
5.3
5.3
5.3
5.3
5.3
8.7
8.7
8.7
8.7
8.7
8.7
110
120
135
150
160
185
4
4
4
4
4
4
5
5
5
5
5
5
8.3
8.3
8.3
8.3
8.3
8.3
4
4
4
4
4
4
5.3
5.3
5.3
5.3
5.3
5.3
8.7
8.7
8.7
8.7
8.7
8.7
210
245
275
300
97.6 107.9 118.2
108,0 122,0 136,0
18
18
18
18
210
245
275
300
4
4
4
4
5
5
5
5
8.3
8.3
8.3
8.3
5.5
5.5
5.5
5.5
6.8
6.8
6.8
6.8
11.6
11.6
11.6
11.6
210
245
275
300
5.5
5.5
5.5
5.5
6.7
6.7
6.7
6.7
11.5
11.5
11.5
11.5
5.5
5.5
5.5
5.5
6.8
6.8
6.8
6.8
11.6
11.6 11.6
11.6
VUGFB102