Ultra low temperature smart freezer under-bench type (72 pages)
Summary of Contents for Daihan Scientific Cef-6
Page 1
Certifications by - - - ISO 9001 Certified. PL Insurance. User Manual (Version 2.3) written for Cef-6/-8/-50.6 "Cef-6" Table-Top Centrifuge, with 6 Holes Fixed Angle Rotor Sales & Basic A/S : By the Nearest Official Distributors. Man 219 (19 Aug. 2015)
This symbol indicates power “OFF” on the power on/off switch. This symbol indicates power “ON” on the power on/off switch. This symbol indicates the connection point of the neutral conductor on the installed unit. This symbol indicates alternating current Voltage. DAIHAN Scientific, General purpose Table-top Centrifuge "Cef-6/-8/-50.6" 3/15...
7. Please be careful so that moisture, organic solvent, dust, corrosive and gas, etc. do not enter into this product. 8. Please do not expose this product in the place where there is direct heat sources. DAIHAN Scientific, General purpose Table-top Centrifuge "Cef-6/-8/-50.6" 5/15...
Product Liability (PL) Insurance Admission ¨ DAIHAN Scientific (Co., Ltd.) is a member of Product Liability Insurance (PL Insurance), so that its customers can trust our products, (believe and use its products,) by preparing against the accident which can be occurred during using the products by self- production.
Do not install the product in a location at an altitude of over 2,000 meters (6,562 feet). Do not operate the product outdoors. Avoid areas where the sun shines directly on the product. It could cause an overheating condition or a short circuit. DAIHAN Scientific, General purpose Table-top Centrifuge "Cef-6/-8/-50.6" 7/15...
Page 8
※ All of the circuits, electrical or mechanical parts and configurations used in this product are the technical assets of DAIHAN Scientific (Co., Ltd.). Only technicians of the technical support team at DAIHAN Scientific (Co., Ltd.) or technicians approved through the education from DAIHAN Scientific should be allowed to repair this product.
Lid Lock Safety Lid Locking ③ Door (Lid) Rotation motion Protection ④ Controller Set and Check operation ⑤ Circular Fixed Angle Rotor Install Sample Tube ⑥ <Table.3.2.1> Names of each part and description DAIHAN Scientific, General purpose Table-top Centrifuge "Cef-6/-8/-50.6" 9/15...
Page 10
DAIHAN-Sci.com or ALL for LAB.com Shopping Mall l Controller ① ② ③ "Cef-6" < Figure 3.2.3> Controller of ④ ⑤ ① ③ ② "Cef-8" < Figure 3.2.4> Controller of ① ② ③ "Cef-50.6" < Figure 3.2.5> Controller of DAIHAN Scientific, General purpose Table-top Centrifuge "Cef-6/-8/-50.6" 10/15...
< Fig 3.3.2. Lid locking> 5. After closing the Lid, please set the timer. 6. Operation Led will blink when start timer. 7. Please set level of speed by turning of speed adjust knob. DAIHAN Scientific, General purpose Table-top Centrifuge "Cef-6/-8/-50.6" 11/15...
Page 12
6 Tubes 4 Tubes < Fig 3.3.3. Tube Balance of Cef-6> 1. Tubes should be used balanced in the same way as the figure. 2. Use of the product in a stage of imbalance causes an accident and products damages.
③ 5~7ml Tube Adapter PP “TA7”, idΦ13.5×L69mm, Fit to “TA15”, Tube Adapter, for Centrifuge “Cef-6”, “Cef-8”, “Cef-50.6”, and “Cef-D50.6” DH.CefA002 ④ 1.5/2ml Tube Adapter PP “TA2”, idΦ11×L42mm, Fit to “TA15”, “TA1503” Tube Adapter, for Centrifuge “Cef-6”, “Cef-8”, “Cef-50.6”, and “Cef-D50.6” DAIHAN Scientific, General purpose Table-top Centrifuge "Cef-6/-8/-50.6" 13/15...
Make sure that Power Cord is plugged well. Check that there are no problems in the power supplied. ※ If you have any problem other than the above, please call technical service of manufacturer or an official agent. DAIHAN Scientific, General purpose Table-top Centrifuge "Cef-6/-8/-50.6" 14/15...
Serial No. Date Customer DAIHAN Scientific Co., Ltd. 326, Sinpyeongseokhwa-ro, jijeong-myeon, Wonj-si, Gangwon-do, Korea Tel : +82 2 967 5235 Fax : +82 963 5231 email : info@daihansci.co.kr -Sci.com www.DAIHAN www.ALL forLAB.com DAIHAN Scientific, General purpose Table-top Centrifuge "Cef-6/-8/-50.6" 15/15...
Page 16
벤처기업 사용자 설명서 (Version 2.3) written for Cef-6/-8/-50.6 "Cef-6" Table-Top Centrifuge, with 6 Holes Fixed Angle Rotor Sales & Basic A/S : By the Nearest Official Distributors. 판매 및 기본 A/S : ㈜대한과학 전국 대리점. Man 219 (19 Aug. 2015)
Page 17
3.2 각 부의 명칭 ..................3.3 사용법 ....................4. 제품 관리법 Accessories ................... 4.2 유지 및 관리 ..................4.3 이상 발생 시 처리 ................. 5. 제품 보증 5.1 품질 보증 .................... 5.2 전국 대리점 ................... DAIHAN Scientific, General purpose Table-top Centrifuge "Cef-6/-8/-50.6" 2/16...
휘발성, 폭발성 화학물질을 사용할 경우 폭발의 위험이 있음을 알립니다. 감전 예방을 위한 접지 표시를 알립니다. ON/OFF 전원 스위치에서 OFF를 나타냅니다. ON/OFF 전원 스위치에서 ON을 나타냅니다. 설치 부 중성선의 접속 포인트를 알립니다. 교류전압을 나타냅니다. DAIHAN Scientific, General purpose Table-top Centrifuge "Cef-6/-8/-50.6" 3/16...
구성품명 적용 모델 및 구성 개수 General Purpose Table-top Centrifuge "Cef-6" 본체 1 Unit (Include Fixed Angle Rotor, 6Holes) General Purpose Table-top Centrifuge "Cef-8" 본체 1 Unit (Include Fixed Angle Rotor, 8Holes) DAIHAN Scientific, General purpose Table-top Centrifuge "Cef-6/-8/-50.6" 4/16...
7. 인화성 가스 누설의 가능성과 유기 증발 가스로 인한 폭발 가능성이 있는 환경에 제품을 설치하지 마십시오. 8. 제품 내부로 습기, 유기용매, 먼지, 부식성 가스 등이 들어가지 않도록 주의하십시오. 9. 제품을 직접적인 열원이 있는 곳에 노출시키지 마십시오. DAIHAN Scientific, General purpose Table-top Centrifuge "Cef-6/-8/-50.6" 5/16...
280 X 280 X h255 mm, 3.5kg 280 X 280 X h265 mm, 4.5kg 300×300×h315mm, 8.5kg Electric Reqts. AC 120V~, 60Hz or AC 230V~, 50/60Hz * Other Specifications are available upon Customer's Request. DAIHAN Scientific, General purpose Table-top Centrifuge "Cef-6/-8/-50.6" 6/16...
2,000 미터 이상의 고도에서 설치하지 마십시오. (6,562 피트) 야외에서 제품을 작동하지 마십시오. 햇빛이 지속적으로 비추는 곳이나 비를 맞을 수 있는 곳에서의 사용을 금합니다. 이는 제품의 과열이나 전기적 결함을 일으킬 수 있습니다. 히터나 에어컨 근처에서 제품을 작동하지 마십시오. DAIHAN Scientific, General purpose Table-top Centrifuge "Cef-6/-8/-50.6" 7/16...
Page 23
전에 장치를 조작하지 마십시오. 감전이나 화재의 원인이 될 수 있습니다. ※ 이 제품에 사용된 모든 회로 및 전기적/기계적 부품 및 구성들은 ㈜대한과학의 기술적 자산입니다. ㈜대한과학의 기술지원팀 기술자나 ㈜대한과학의 교육을 통해 인정한 기술자 에게 수리를 의뢰하시기 바랍니다. DAIHAN Scientific, General purpose Table-top Centrifuge "Cef-6/-8/-50.6" 8/16...
Lid 잠금 장치 Lid Lock ③ Door (Lid) ④ 회전 동작 보호 ⑤ 조절기 제품의 동작을 조절, 확인 Sample Tube 장착 Circular Fixed Angle Rotor ⑥ <Table.3.2.1> 각 부의 명칭 및 설명 DAIHAN Scientific, General purpose Table-top Centrifuge "Cef-6/-8/-50.6" 9/16...
Page 25
DAIHAN-Sci.com or ALL for LAB.com Shopping Mall l 조절기 ① ② ③ "Cef-6" < Figure 3.2.3> Controller of ④ ⑤ ① ③ ② "Cef-8" < Figure 3.2.4> Controller of ① ② ③ "Cef-50.6" < Figure 3.2.5> Controller of DAIHAN Scientific, General purpose Table-top Centrifuge "Cef-6/-8/-50.6" 10/16...
< Fig 3.3.1. Lid 잠금 해제> < Fig 3.3.2. Lid 잠금 설정> 5. Lid를 잠근 후 타이머를 조절합니다. 타이머 조절 노브로 원하는 분단위를 조절합니다. 6. 타이머가 동작되면 Operation LED가 점등됩니다. 7. 속도 조절 노브를 돌려서 속도단계를 조절합니다. DAIHAN Scientific, General purpose Table-top Centrifuge "Cef-6/-8/-50.6" 11/16...
Page 27
2. 불균형 상태로 제품을 사용하시면 사고 및 제품의 이상 원인이 발생될 수 있습니다. 3. “편심”이 발생 할 경우 즉시 사용을 정지하고, 균형을 맞추어서 다시 사용합니다. 4. 각각의 튜브에는 같은 양과 무게의 샘플이 담겨있어야 합니다. * Cef-6 Model Cef-6 모델의 Speed Step에 따른 RPM 평균수치는 아래 표와 같습니다. Speed Step 1010...
③ 5~7ml Tube Adapter PP “TA7”, idΦ13.5×L69mm, Fit to “TA15”, Tube Adapter, for Centrifuge “Cef-6”, “Cef-8”, “Cef-50.6”, and “Cef-D50.6” DH.CefA002 ④ 1.5/2ml Tube Adapter PP “TA2”, idΦ11×L42mm, Fit to “TA15”, “TA1503” Tube Adapter, for Centrifuge “Cef-6”, “Cef-8”, “Cef-50.6”, and “Cef-D50.6” DAIHAN Scientific, General purpose Table-top Centrifuge "Cef-6/-8/-50.6" 13/16...
Power Cord가 잘 꽂혀 있는지 확인합니다. Fuse가 끊어져 있는지 확인합니다. 전원이 들어오지 않는 경우 공급되는 전력에 이상이 없는지 확인합니다. ※ 상기 내용을 확인하여도 이상 증상이 계속될 경우, 구매한 대리점이나 본사 서비스센터 080-008-3000으로 연락하셔서 A/S를 의뢰하시기 바랍니다. DAIHAN Scientific, General purpose Table-top Centrifuge "Cef-6/-8/-50.6" 14/16...
033-262-7729 포항 대한사이언스 (대표 엄청호) 경상북도 포항시 남구 효자로 118번길 46-2 054-275-1018 054-274-1014 (주) 대 한 과 학 ㈜대한과학 Call Center 080-008-3000(본사) 080-008-9009(대전) Call Center 080-008-3000(본사) 080-008-9009(대전) 서울사업소 : 02-967-5235 E-mail: info@daihansci.co.kr DAIHAN Scientific, General purpose Table-top Centrifuge "Cef-6/-8/-50.6" 16/16...