Download Print this page
Dover DESTACO 810 Series Installation Instructions

Dover DESTACO 810 Series Installation Instructions

Pneumatic hold down clamps

Advertisement

Quick Links

Warranty
All DESTACO products are thoroughly inspected and tested. We fully guarantee all materials to be free of defects. Any product that is found to be defective will be promptly 
replaced. This warranty does not apply to any product where the failure of misapplication or abuse,  nor is there any warranty expressed or implied as to the merchantability 
of the product. This warranty is null and void if the product is altered in any way without factory consent. Removing and or modifying the  clamp's internal flow restrictor, and 
or violating any of the conditions mentioned above will void this warranty. DESTACO is not liable for labor, Special or consequential damages and under no circumstances any 
charges in excess of the invoice amount of the product proven to be defective.
Maintenance and Service
For proper operation, clean, dry air is required. This cylinder is shipped with internally applied lubricant and should not require lubricant for the life of the product. Using 
lubricated air will "wash out" the lubricant applied at the factory. Using lubricated air is acceptable as long as it is maintained over the life of the product and that the 
lubrication used is compatible with the clamp. (Seal material is Buna‐N & Urethane).
An occasional light spray of  a penetrating oil at the pivot points will increase the life of the clamp. The frequency or need to do this at all is based on the application where 
used.
Installation
Toggle mechanisms are capable of creating very high forces. The force increases dramatically as the clamp approaches toggle. It may be possible to exert more force than the 
rated holding capacity of the clamp. This will cause the clamp to fail prematurely.
During initial setup observe the clamp as it cycles paying close attention as it approaches toggle lock. If the clamp hesitates during this time it is likely exerting too much force. 
Reduce the amount of interference by adjusting the spindle or shimming the clamp until there is slight hesitation only.
To obtain the maximum cycle life from this product it is not recommended exceeding the arm weight shown in the chart. This 
weight includes the supplied spindle, washers and hex nuts. Although the clamp will operate with more weight than shown, any 
additional weight added will reduce the cycle life.
Specifications
MODEL
BORE
802
20mm
[.787]
10mm [.394]
807
25mm
[.984]
10mm [.394]
810
32mm
[1.260]
12mm [.472]
Models: 802, 807 & 810 PNEUMATIC HOLD DOWN CLAMPS
ROD
CLAMP STROKE
39mm [1.535]
48mm [1.890]
63mm
[2.480]
INSTALLATION INSTRUCTIONS
VOLUME PER STROKE
NOMINAL WORKING PRESSURE
21 cm³
[1.31 in³]
5.5 ‐ 6.2 bar
43 cm³
[2.65 in³]
5.5 ‐ 6.2 bar
94 cm³
[5.75 in³]
5.5 ‐ 6.2 bar
DOC No:
Revision:
MAXIMUM RECOMMENDED ARM 
MODEL
802
100 g
807
142 g
810
MAXIMUM OPERATING 
PRESSURE
[80‐90 psi]
8.3 bar [120 psi]
[80‐90 psi]
8.3 bar
[120 psi]
[80‐90 psi]
8.3 bar
[120 psi]
NPN‐80X‐1
Sheet 1 of 2
1
12/12/2018
WEIGHT
57 g
[2.0 oz]
[3.5 oz]
[5.0 oz]
MINIMUM 
OPERATING 
PRESSURE
2.8 bar [40 psi]
2.8 bar [40 psi]
2.8 bar [40 psi]
DESTACO
Copyright 

Advertisement

loading
Need help?

Need help?

Do you have a question about the DESTACO 810 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Dover DESTACO 810 Series

  • Page 1 NPN‐80X‐1 DOC No: INSTALLATION INSTRUCTIONS Sheet 1 of 2 Models: 802, 807 & 810 PNEUMATIC HOLD DOWN CLAMPS Revision: 12/12/2018 Warranty All DESTACO products are thoroughly inspected and tested. We fully guarantee all materials to be free of defects. Any product that is found to be defective will be promptly  replaced. This warranty does not apply to any product where the failure of misapplication or abuse,  nor is there any warranty expressed or implied as to the merchantability  of the product. This warranty is null and void if the product is altered in any way without factory consent. Removing and or modifying the  clamp’s internal flow restrictor, and  or violating any of the conditions mentioned above will void this warranty. DESTACO is not liable for labor, Special or consequential damages and under no circumstances any  charges in excess of the invoice amount of the product proven to be defective. Maintenance and Service For proper operation, clean, dry air is required. This cylinder is shipped with internally applied lubricant and should not require lubricant for the life of the product. Using  lubricated air will “wash out” the lubricant applied at the factory. Using lubricated air is acceptable as long as it is maintained over the life of the product and that the  lubrication used is compatible with the clamp. (Seal material is Buna‐N & Urethane). An occasional light spray of  a penetrating oil at the pivot points will increase the life of the clamp. The frequency or need to do this at all is based on the application where  used. Installation Toggle mechanisms are capable of creating very high forces. The force increases dramatically as the clamp approaches toggle. It may be possible to exert more force than the  rated holding capacity of the clamp. This will cause the clamp to fail prematurely. During initial setup observe the clamp as it cycles paying close attention as it approaches toggle lock. If the clamp hesitates during this time it is likely exerting too much force.  Reduce the amount of interference by adjusting the spindle or shimming the clamp until there is slight hesitation only. To obtain the maximum cycle life from this product it is not recommended exceeding the arm weight shown in the chart. This  MAXIMUM RECOMMENDED ARM  MODEL WEIGHT weight includes the supplied spindle, washers and hex nuts. Although the clamp will operate with more weight than shown, any  57 g [2.0 oz] additional weight added will reduce the cycle life. 100 g [3.5 oz] 142 g [5.0 oz] Specifications MINIMUM  MAXIMUM OPERATING  MODEL BORE CLAMP STROKE VOLUME PER STROKE...
  • Page 2 NPN‐80X‐1 INSTALLATION INSTRUCTIONS Sheet Models: 802, 807 & 810 PNEUMATIC HOLD DOWN CLAMPS Revision: 12/12/2018 These parts are available through your authorized DESTACO distributor.  REPLACEMENT CLAMP LESS CYLINDER REPLACEMENT CYLINDER ASSEMBLY REPLACEMENT REPLACEMENT LESS CYLINDER MODEL CLAMP CYLINDER ASS'Y 802‐U‐RC 802‐U‐LC 802CYL 802‐U 802‐UE 802‐U‐RC 802‐U‐LC 802CYLG 807‐U‐RC 807‐U‐LC 807CYL 807‐U 807‐UE 807‐U‐RC 807‐U‐LC 807CYLG 807‐S 807‐S‐RC 807‐S‐LC 807CYL 807‐SE 807‐S‐RC 807‐S‐LC 807CYLG 810‐U 810‐U‐RC 810‐U‐LC...

This manual is also suitable for:

Destaco 802Destaco 807802-u802-ue807-u807-ue ... Show all