Brinkmann Immersions pumps of the series TS12 ... 24 Contents Indication to the manual ........2 Servicing and Maintenance ....... 6 Trouble shooter’s guide ........7 Description of product ........2 Safety instructions ..........4 Spare part ............8 Transport and storage ........4 Disposal ............
Page 3
Technical data Max. del. Max. del. Height Depth of Weight Power Noise pressure bar / volume immersion 50 / 60 Hz level Type spec. weight 1 l/min H mm h mm dBA / 50 Hz TS12 / 110 0.32 / 0.365 / 150 / 190...
3 Safety instructions Safety instructions relevant for opera- When operating the pump, the safety instructions tion contained in this manual, the relevant national • If hot or cold machine components involve accident prevention regulations and any other hazards, they must be guarded against acci- service and safety instructions issued by the plant dental contact.
Electric wiring 5 Installation and Connection Mechanical installation During any assembly or disassembly process the pumps must be secured against tipping trough ropes for example at all times. All service work must be carried out by quali- Pumps must be mounted securely. Piping, tank and fied service personnel.
Wiring diagram e.g. Star connection 3 x 400 V, 50 Hz resp. 380-415 V, 50 Hz Delta connection 3 x 230 V, 50 Hz resp. 220-240 V, 50 Hz max. liquid level min. liquid There may be no foreign objects such as dirt, level particles or humidity inside the terminal board.
9 Trouble shooter’s guide Fault Cause Remedy Motor does not start, no motor At least two of the power supply Check fuses, terminals and supply noise leads have failed leads . Overload has tripped Inspect overload Motor does not start, humming noise One of the supply leads has failed See above Impeller faulty...
10 Spare part 10.1 Spare part list for the immersion pumps of the series TS12 ... 24 Item Description Stator with terminal board Pump body Shaft with rotor Inlet cover Impeller Pump plate TS15, TS24 End shield TS13…TS24 Fan cover 10 Terminal box 11 Ball bearing DIN 625...
Manufacturer Brinkmann Pumpen, K. H. Brinkmann GmbH & Co. KG Friedrichstraße 2 D-58791 Werdohl Germany This declaration of conformity is issued under the sole responsibility of Brinkmann Pumps and belongs to the following product. Product name Immersion pumps TS21…24 Type The named product described above complies with the following statutory requirements of United Kingdom: UK SI 2008 No.
Page 10
12.2 EC declaration of conformity DEUTSCH / ENGLISH /FRANÇAIS / ESPAÑOL EG-Konformitätserklärung EC declaration of conformity / Déclaration de conformité CE / Declaración de conformidad CE Hersteller / Manufacturer / Constructeur / Fabricante Brinkmann Pumpen, K. H. Brinkmann GmbH & Co. KG Friedrichstraße 2, D-58791 Werdohl Produktbezeichnung / Product name / Désignation du produit / Designación del producto Tauchpumpen / Immersion pumps / Pompes plongeantes / Bombas de inmersión...