Brinkmann Stainless Steel Immersions pumps of the series TVG400…1000, TVA400…900 Contents 9 Trouble shooter’s guide ........7 Indication to the manual ........2 Description of product ........2-3 10 Spare part ............8-9 Safety instructions ..........4 11 Repair ............... 9 Transport and storage ........
Page 3
Technical data Max. del. Max. del. Height Depth of Weight Power Noise pressure bar / volume immersion level Type spec. weight 1 l/min H mm h mm TVG400 / 360 1.7 / 50 Hz 1100 1098 TVG400 / 360 60 Hz 2.94 / 60 Hz 580 60 Hz 880 60 Hz...
Safety instructions relevant for operation 3 Safety instructions • If hot or cold machine components involve haz- When operating the pump, the safety instructions contained in this manual, the relevant national acci- ards, they must be guarded against accidental dent prevention regulations and any other service contact.
5 Installation and Connection Mechanical installation During any assembly or disassembly process the pumps must be secured against tipping trough ropes The pump must be mounted in that way that ro- for example at all times. tating parts under the cover of the coolant tank Pumps must be mounted securely.
ATTENTION When Variable Frequency Drives are used interfer- ing signals might occur. Non-sinus shaped supply voltage from a variable fre- If the pump should lock up and cease, shut pump quency drive might result in elevated motor temper- down (see 6.2) and disconnect from power sup- atures.
9 Trouble shooter’s guide Fault Cause Remedy Motor does not start, no motor At least two of the power supply Check fuses, terminals and supply noise leads have failed leads . Overload has tripped Inspect overload Motor does not start, humming noise One of the supply leads has failed See above Impeller faulty...
10 Spare part 10.1 Spare part list for the immersion pumps of the series TVG, TVA Item Description Stator with terminal board Motor flange End shield Terminal box Terminal box frame up 6.0 kW Terminal box cover up 6.0 kW Fan cover Ball bearing up to 2.94 kW DIN 628...
10.2 Indications to the spare part order 11.2 Assembling the insert shaft and motor shaft Spare parts are available from the supplier. Standard commercially available parts are to be pur- ATTENTION chased in accordance with the model type. The ordering of spare parts should contain the fol- Clean the contact surfaces of the insert shaft (2) lowing details: (inside) and the motor shaft (3).
Manufacturer Brinkmann Pumpen, K. H. Brinkmann GmbH & Co. KG Friedrichstraße 2 D-58791 Werdohl Germany This declaration of conformity is issued under the sole responsibility of Brinkmann Pumps and belongs to the following product. Product name Immersion pumps TVG400…1000, TVA400…900...
Page 11
13.2 EC declaration of conformity DEUTSCH / ENGLISH /FRANÇAIS / ESPAÑOL EG-Konformitätserklärung EC declaration of conformity / Déclaration de conformité CE / Declaración de conformidad CE Hersteller / Manufacturer / Constructeur / Fabricante Brinkmann Pumpen, K. H. Brinkmann GmbH & Co. KG Friedrichstraße 2, D-58791 Werdohl Produktbezeichnung / Product name / Désignation du produit / Designación del producto Tauchpumpen / Immersion pumps / Pompes plongeantes / Bombas de inmersión...