Nomenclature and Functions
Display
Status Indicators for I/O Slave Stations
Indicator
(1) PWR
Green
(2) ERR
Red
(3) MS
Red
(Module Status)
Green
---
(4) WS
Red
(Wireless Status)
Green
---
(5) RSSI (See note 2.)
Red/yellow/
(Received Signal
green
Strength Indicator)
Green
(6) 0 to 15
Yellow
Field strength
Number of indicators lit
RUN mode
TEST mode
Field strength monitor
test
Installation/confirmation test
12
(1)
(2)
PWR
ERR
Color
Status
Lit
Power is being supplied.
Not lit
Power is not being supplied.
Lit
Error output is ON: Wireless device error, wireless communications
error, or host network error has occurred preventing normal
I/O communications.
Not lit
Error output is OFF: Causes of the above conditions have been
removed.
Lit
A fatal error has occurred that cannot be recovered from, such as a
watchdog timer error, EEPROM error, or hardware error. Replace the
WT30 Terminal.
Flashing
A non-fatal error, illegal switch settings, or EEPROM checksum error
has occurred that can be recovered from by resetting the system.
Lit
Communications are normal.
Flashing
TEST mode or SET mode has been activated.
Not lit
Power is not being supplied or the system is resetting.
Lit
A fatal wireless communications error has occurred, or duplicate wire-
less node addresses have been set.
Flashing
A non-fatal communications error, disconnection, or communications
timeout has occurred.
Lit
RUN mode: Connection to wireless communications is completed.
Flashing
RUN mode: Wireless communications not connected.
TEST mode: Received signal strength monitoring in progress.
Not lit
No wireless communications
0 to 9 lit
Displays the received signal strength in 10 levels. The field strength is
determined by the number of indicators lit: weak for a small number
and strong for a large number.
Flashing
Special function operation has completed.
Lit/not lit
Input or output signal ON/OFF status (0 to 7, 8 to 15)
Note
(1) For details on troubleshooting, refer to 5-1 Troubleshooting on page 68.
(2) The RSSI can be used to confirm the operation status.
Red indicators
Weak
0
1
Unstable communications range
Range in which
specified channel
can be used.
Unstable communications range
The received signal strength is indicated using 10 levels. Check the communi-
cations status, referring to the field strength level.
(6)
0 1 2 3 4 5 6 7
IN
8 9 10 1 1 12 13 14 15
MS
WS
(3)
(4)
Meaning (primary error)
Yellow indicators
Medium
2
3
4
5
Stable communications range
Range in which specified channel cannot be used.
Stable communications range
Section 1-2
(5)
RSSI
1
9
Green indicators
Strong
6
7
8
9

Advertisement