Device inspection, secure module

Advertisement

DynaProx and DynaProx BCR | Device Inspection
Form Factor and Labeling
Underside
Carefully inspect the form factor. Make certain there are no additional
electronics, wires, or forms added to the device. The underside of DynaProx
and DynaProx BCR are the same. The underside of the device is a smooth
form factor with 4 threaded screw holes, a USB-C receptacle, RS-232
receptacle, and product label.
Mounting Insets
There are four (4) threaded inset receptacles on the underside of the device.
Product Label
The product label is located on the underside of the device. The Serial
Number, Rev, Date, Part number (PN), Hardware PN (HW), FCC ID and IC
numbers are printed on the product label. Compare the hardware ID to PCI
website and confirm it is valid.
USB-C
USB-C connection is on the underside of the device. Ensure the cable is
connected directly to the correct host USB port.
Certificate Logos
Imprints in the plastic form factor of certification logos and patent
information are listed.
RS-232
RS-232 connection is on the underside of the device. Ensure the cable is
connected directly to the correct host port.
PCI DEVICE VALIDATION
To check for PCI Validation check the Hardware and Firmware ID. Hardware
ID is printed on the label.The Firmware ID is accessible via the device and
displayed on the screen. Go to the PCI compliance web page and search for
MagTek, and find the product name, DynaProx. Compare the Hardware ID
and Firmware ID:
https://www.pcisecuritystandards.org/assessors_and_solutions/pin_transaction_devices
Please note that the use of this accessory with an Apple product may affect wireless performance. Apple®, Apple Pay®, OS X®, iPhone®, iPad®, iPad Air®, iPad Pro®, Lightning®, and Mac® are trademarks of Apple Inc., registered in the U.S. and other countries.
EMV® is a registered trademark in the U.S. and other countries and an unregistered trademark elsewhere. The EMV trademark is owned by EMVCo, LLC. The Contactless Indicator mark, consisting of four graduating arcs, is a trademark owned by and used with
permission of EMVCo, LLC.
MagTek® Inc. | www.magtek.com |
MagTek
Inc., 1710 Apollo Court, Seal Beach CA 90740 | p 562-546-6400 | support 651-415-6800 | f 562-546-6301 | www.magtek.com
®
Checklist
As part of your inspection, include the following for your device inspection
audit:
• Be certain to have a list of the devices and include the details listed on
the product label.
• It may be helpful to take photos of the front, back, and side of each
device.
Be certain to check device part numbers, serial numbers and IDs and check
physical connections. Use the chart below as a checklist to inspect the
device for signs of tampering.
Site Inspection
Form Factor - check overall form factor
Front
Contactless Landing Zone
Barcode reader (BCR only)
Sides
Form Factor
Right, Left, Top, Bottom edges
Cables
USB-C cable (if applicable)
RS-232 (if applicable)
Underside
Certificate Logos (imprinted)
Form Factor
Cable Connection
Mounting screw insets
Labels
If there is forced entry, the security switches built into the electronics will be
tripped. If they are tripped the sensitive data such as encryption keys and
certificates are cleared as part of security measures mandated by PCI and
the device will not be available to make transactions.
NOTICE:
If the security switches have been tripped, DynaProx and Dy-
naProx BCR cannot be repaired in the field and must go back to the factory
for repair. Follow RMA procedures. User must report all signs of tampering
as per standard protocol.
Registered to ISO 9001:2015 © Copyright 2022 MagTek, Inc. D998200502 rev. 10 7/22
Are there signs of tampering:
Signs of tampering
YES
NO