Omron SMARTSTEP SERVO DRIVE System Configuration Manual page 6

Smartstep r7d-ap series servo drive
Table of Contents

Advertisement

Enable switch/parameter setting
Pin 6 of the DIP switch selects whether the servo drive operates according to the
DIP switch settings or parameter settings
ON OFF
Pin 6
OFF
6
ON
5
4
3
2
1
(Default setting)
Online autotuning setting
The autotuning switch selects whether the gain will be adjusted auto-
matically during operation.
ON OFF
Perform online autotuning.
1
ON OFF
Complete online autotuning.
The result is stored in the inertia ratio
1
parameter (Pn103) and the servo drive
runs.
Resolution setting
Pins 4 and 5 select the positioning resolution.
If the resolution is set to 1,000 (the default setting), the motor makes
one revolution for every 1,000 pulses input.
Pins
ON OFF
5
6
OFF
5
OFF
4
ON
3
2
ON
1
(Default setting)
Alarm Table
Display
ALM output
A.04*
OFF
Parameter setting error
OFF
A.10*
Overcurrent
A.30
OFF
Regeneration error
A.32
OFF
Regeneration overload
A.40
OFF
Overvoltage/undervoltage
A.51
OFF
Overspeed
A.70
OFF
Overload
A.73
OFF
Dynamic brake overload
A.74
OFF
Inrush resistance overload
These parameters are read when the power is turned
Note:
1.
ON. Parameter Pn110.2 is valid when online.
158
.
Function
Enables the DIP switch settings.
Enables the parameter settings.
Resolution
4
OFF
1,000 pulses/revolution
(0.36 /step)
ON
10,000 pulses/revolution
(0.036 /step)
OFF
500 pulses/revolution
(0.72 /step)
ON
5,000 pulses/revolution
(0.072 /step)
Error detection function
Command pulse input setting
Pin 3 selects the command pulse mode. Select "Forward pulse/reverse
pulse: positive logic" or "feed pulses/direction signal: positive logic."
ON OFF
6
5
Pin 3
OFF
4
3
ON
2
1
(Default setting)
Dynamic brake setting
Pin 2 enables or disables dynamic brake operation. If the dynamic brake is ena-
bled, the motor can be brought to an emergency stop when the RUN command
goes OFF or an alarm occurs.
ON OFF
6
5
4
3
Pin 2
OFF
2
ON
1
(Default setting)
Display
ALM output
A.7A
OFF
Overheat
OFF
A.bF*
System error
A.C1
OFF
Runaway detected
A.C2*
OFF
Phase not detected
A.C3*
OFF
Encoder disconnect detected
A.d0
OFF
Deviation counter overflow
CPF00
---
Parameter unit transmission error 1
CPF01
---
Parameter unit transmission error 2
A.91
---
Overload warning
A.92
---
Regeneration overload warning
When using a regeneration resistor, set the resistor's
2.
capacity when the temperature has risen to 120 C.
Set this parameter to 0 if a regeneration resistor is not
being used.
Command pulse mode
Forward pulse/reverse pulse:
positive logic
Feed pulses/direction signal:
positive logic
Dynamic brake mode
Dynamic brake disabled.
Dynamic brake enabled.
Error detection function
AC servo systems

Hide quick links:

Advertisement

Table of Contents
loading