Standard Connection - Omron SJDE-APA-OY User Manual

Junma series servo drive
Table of Contents

Advertisement

3.3 Standard Connection

3.3 Standard Connection
Power supply
Single-phase 200 V to 230 VAC
50/60Hz
L1
L2
Molded-case circuit breaker
Surge protector
Noise
filter
SW1
SW2
MC1
Regenerative unit
200 V to
AVR2
230 VAC
24 V power
supply
+ 24V 0V
Controller
Note: 1. AVR1:24 VDC power
supply for brake
AVR2: 24 VDC power sup-
ply for sequence
SW1: Power OFF switch
SW2: Power ON switch
MC1: Magnetic contactor
Ry1: Brake relay
MC1
MC1
Fuse
Spark
killer
Fuse
+
C1
C2
JUSP-
Y4
RG08D
Y5
CW,PULS
/CW,/PULS
CCW,SIGN
/CCW,/SIGN
2.2kΩ
/CLR
SG-PCO
+24VIN
MC1
/S-ON
Ry1
Flywheel diode
/COIN
SG-COM
Shield
• Parts example
Spark killer
Flywheel diode
Brake relay
Varistor
AVR1*
Ry1
24 V power supply
+ 24V
200 V to
230 VAC
0V
SERVOPACK
CNA
L1
1
2
L2
+
3
Shell
4
CN1
75Ω
1
75Ω
2
75Ω
3
75Ω
4
75Ω
CLR
8
75Ω
9
10
PCO
11
5
6
3.4kΩ
ALM
12
Shell
/BK
13
14
7
Shell
Okaya Electric Industries Co., Ltd. CRE-50500
Toshiba Corporation 1NH42
OMRON Corporation MY series
Nippon Chemi-Con Corporation TNR7V121K
24
Varistor
CNB
1
U
2
V
3
W
Shield
CN2
1
PG5V
2
PG0V
A +
3
4
A−
B +
5
6
B−
7
/Z
8
U
9
V
10
W
Shield
* Prepare a 24-VDC power supply
for the brake separate from the
sequence power supply.
5
Brake
6
1
U
2
Servomotor
V
3
W
FG
4
1
2
3
4
5
6
Encoder
7
8
9
10
12

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Junma sjde-**apa-oy

Table of Contents