Standard Connections

3-phase 200 V AC
single-phase 200 V AC
(see note 1)
Multi-function input 1 (S2)
Multi-function input 2 (S3)
Multi-function input 3 (S4)
Multi-function input 4 (S5)
Sequence input common
Frequency reference power
supply 20mA at +12V
External frequency
Frequency reference input
adjuster
(2 kΩ 1/4 W min.)
Frequency reference common
Note 1: Connect single-phase 200 V AC to terminals R/L1 and S/L2 of the 3G3JV-AB .
Note 2: The braking resistor cannot be connected because no braking transistor is incorporated.
3G3JV PFI
Noise Filter
L1
L2
L3
Forward/Stop
+1
+2
L1í
R/L1
L2í
S/L2
L3í
T/L3
S1
S2
S3
S4
S5
SC
FS
FR
FC
Multi-function contact output
MA
NO
MB
NC
MC
Common
AM
Analogue monitor output
AC
Analogue monitor output
common
M