GENTILIN CSK 240/03 Instruction Manual
Hide thumbs Also See for CSK 240/03:

Advertisement

Quick Links

Instruction Manual
Compressors
CSK 240/03
CSK 240/5+5
CSK 240/24
CSK 240/50
CSK 240/100
ESK 480/100
ESK 660/100
EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CSK 240/03 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for GENTILIN CSK 240/03

  • Page 1 Instruction Manual Compressors CSK 240/03 CSK 240/5+5 CSK 240/24 CSK 240/50 CSK 240/100 ESK 480/100 ESK 660/100...
  • Page 3: Table Of Contents

    Instruction Manual - Compressors CSK 240/03 - CSK 240/5+5 - CSK 240/24 - CSK 240/50 - CSK 240/100 - ESK 480/100 - ESK 660/100 indEx PARTS LiST ........................... 4 TECHniCAL SPECiFiCATiOnS ......................6 CE dECLARATiOn OF COnFORMiTY ....................8 CE LABEL ............................8 iMPORTAnCE OF THE MAnUAL ......................
  • Page 4: Parts List

    Instruction Manual - Compressors CSK 240/03 - CSK 240/5+5 - CSK 240/24 - CSK 240/50 - CSK 240/100 - ESK 480/100 - ESK 660/100 PARTS LiST Non-return valve Adjustable handle ON (I) – OFF (O) switch Air filter Outlet pressure regulator...
  • Page 5 Instruction Manual - Compressors CSK 240/03 - CSK 240/5+5 - CSK 240/24 - CSK 240/50 - CSK 240/100 - ESK 480/100 - ESK 660/100 MOd. CSK 240/5+5 MOd. CSK 240/24 - CSK 240/50 www.gentilinair.com MAN_CSK_ESC_A001 - 11/2021...
  • Page 6: Technical Specifications

    Instruction Manual - Compressors CSK 240/03 - CSK 240/5+5 - CSK 240/24 - CSK 240/50 - CSK 240/100 - ESK 480/100 - ESK 660/100 MOd. CSK 240/100 TECHniCAL SPECiFiCATiOnS MOdEL CSK 240/03 CSK 240/5+5 CSK 240/24-50 CSK 240/100 50 Hz...
  • Page 7 Instruction Manual - Compressors CSK 240/03 - CSK 240/5+5 - CSK 240/24 - CSK 240/50 - CSK 240/100 - ESK 480/100 - ESK 660/100 MOd. CSK 240/03 MOd. CSK 240/100 MOdEL ESK 480/100 ESK 660/100 Supply voltage/Frequency 230/50 V/Hz - 400/50 V/Hz...
  • Page 8: Ce Declaration Of Conformity

    Gentilin S.r.l. - Via delle Tezze, 20/22 36070 Trissino (VI) - Italy - VAT N.: 01262520248 Declares that the following machine: COMPRESSOR CSK 240/03 - CSK 240/5+5 - CSK 240/24 - CSK 240/50 - CSK 240/100 - ESK 480/100 - ESK 660/100 MACHINE: Air volumetric compressor...
  • Page 9: Importance Of The Manual

    Instruction Manual - Compressors CSK 240/03 - CSK 240/5+5 - CSK 240/24 - CSK 240/50 - CSK 240/100 - ESK 480/100 - ESK 660/100 iMPORTAnCE OF THE MAnUAL BEFORE USING THE APPLIANCE IN QUESTION, AUTHORISED USERS MUST READ AND UNDERSTAND THE PRESENT INSTRUCTION MANUAL IN ITS ENTIRETY.
  • Page 10: Status "Appliance Off

    Instruction Manual - Compressors CSK 240/03 - CSK 240/5+5 - CSK 240/24 - CSK 240/50 - CSK 240/100 - ESK 480/100 - ESK 660/100 COMPAnY SAFETY MAnAGER: A qualified technician nominated by the employer (where the appliance is used in a business context), who possesses the required professional, technical skills as specified by the legislations currently in force on health and safety of workers at the work place.
  • Page 11: Warranty

    Instruction Manual - Compressors CSK 240/03 - CSK 240/5+5 - CSK 240/24 - CSK 240/50 - CSK 240/100 - ESK 480/100 - ESK 660/100 WARRAnTY 1) GUARAnTEE dECLARATiOn: the Manufacturer gives an undertaking to the End-user to replace, repair or otherwise intervene in the machine, if it has conformity defects that compromise its correct use and operation, but only if such defects are attributable to the actual liability of the Manufacturer.
  • Page 12: Incorrect Use

    Instruction Manual - Compressors CSK 240/03 - CSK 240/5+5 - CSK 240/24 - CSK 240/50 - CSK 240/100 - ESK 480/100 - ESK 660/100 PLACE OF OPERATiOn Interior locations with sufficient lighting, ventilation, with temperature and air humidity values as per details provided in Pa- ragraph “TECHNICAL SPECIFICATIONS”, in compliance with legislation governing health and safety in the work place in force in the country of usage.
  • Page 13: Transportation And Movement Of The Appliance

    Instruction Manual - Compressors CSK 240/03 - CSK 240/5+5 - CSK 240/24 - CSK 240/50 - CSK 240/100 - ESK 480/100 - ESK 660/100 TRAnSPORTATiOn And MOVEMEnT OF THE APPLiAnCE The appliance may be manually transported by two qualified operators, gripping it by the foot (A) and...
  • Page 14: Storage

    Instruction Manual - Compressors CSK 240/03 - CSK 240/5+5 - CSK 240/24 - CSK 240/50 - CSK 240/100 - ESK 480/100 - ESK 660/100 STORAGE • In the instance where the appliance is not to be used for an extended period of time, it must be stored in a safe place, with suitable temperature and air humidity values, where it is protected from dust.
  • Page 15: Safety Devices Adopted

    Instruction Manual - Compressors CSK 240/03 - CSK 240/5+5 - CSK 240/24 - CSK 240/50 - CSK 240/100 - ESK 480/100 - ESK 660/100 SAFETY dEViCES AdOPTEd • SAFETY VALVE (15): a certified safety valve (set to 10.5 bar), installed to the pneumatic system, under the pressure switch. It tackles over-pressure in the instance where, owing to anomalies, the pressure switch does not function.
  • Page 16: Safety Signs

    Instruction Manual - Compressors CSK 240/03 - CSK 240/5+5 - CSK 240/24 - CSK 240/50 - CSK 240/100 - ESK 480/100 - ESK 660/100 SAFETY SiGnS Safety signs used take the formof a sticky label, applied to the appliance exterior.
  • Page 17: Residual Risks

    Instruction Manual - Compressors CSK 240/03 - CSK 240/5+5 - CSK 240/24 - CSK 240/50 - CSK 240/100 - ESK 480/100 - ESK 660/100 RESidUAL RiSKS Although the Manufacturer has adopted all technical construction solutions in order to make the appliance as safe as pos- sible, authorised operators please be aware that residual risks remain.
  • Page 18: Command Devices

    Instruction Manual - Compressors CSK 240/03 - CSK 240/5+5 - CSK 240/24 - CSK 240/50 - CSK 240/100 - ESK 480/100 - ESK 660/100 COMMAnd dEViCES The command devices are: Air outlet spigot Outlet pressure regulator “ON-OFF” switch Pressure switch...
  • Page 19: Appliance Activation

    Instruction Manual - Compressors CSK 240/03 - CSK 240/5+5 - CSK 240/24 - CSK 240/50 - CSK 240/100 - ESK 480/100 - ESK 660/100 APPLiAnCE ACTiVATiOn DANGER OF BURNS UPON ACCIDENTAL CONTACT WITH THE TWIN CYLINDER PUMP SYSTEM AND ELECTRIC MOTOR.
  • Page 20: Appliance Deactivation

    Instruction Manual - Compressors CSK 240/03 - CSK 240/5+5 - CSK 240/24 - CSK 240/50 - CSK 240/100 - ESK 480/100 - ESK 660/100 APPLiAnCE dEACTiVATiOn At the end of operations, switch off the appliance as follows: 1) Switch off the appliance using the “ON-OFF” switch (3) ensuring it is set to “OFF (0)”.
  • Page 21: Reset Intervention - Thermal Restore

    Instruction Manual - Compressors CSK 240/03 - CSK 240/5+5 - CSK 240/24 - CSK 240/50 - CSK 240/100 - ESK 480/100 - ESK 660/100 RESET inTERVEnTiOn – THERMAL RESTORE In the instance where current overload and/or a short circuit of the appliance electrical system is noted, the thermal restore intervenes, disabling the electric motor.
  • Page 22 Instruction Manual - Compressors CSK 240/03 - CSK 240/5+5 - CSK 240/24 - CSK 240/50 - CSK 240/100 - ESK 480/100 - ESK 660/100 STAndARd MAinTEnAnCE TABLE FREQUEnCY inTERVEnTiOn AREA inTERVEnTiOn TYPE OnCE A dAY Safety devices. Ensure they are intact, correctly installed and functioning.
  • Page 23: Extraordinary Maintenance

    Instruction Manual - Compressors CSK 240/03 - CSK 240/5+5 - CSK 240/24 - CSK 240/50 - CSK 240/100 - ESK 480/100 - ESK 660/100 ExTRAORdinARY MAinTEnAnCE All activities carried out to ensure use and operation of the appliance, via various intervention types (regulation, valve checks, cleaning of air filters, etc.) executed by the Manufacturer’s technicians according to preestablished time intervals and in the...
  • Page 24 Instruction Manual - Compressors CSK 240/03 - CSK 240/5+5 - CSK 240/24 - CSK 240/50 - CSK 240/100 - ESK 480/100 - ESK 660/100 ABnORMALiTiES CAUSE SOLUTiOn The appliance restarts nu- Leakages from the air pipe, • Check that the pneumatic system is not damaged.

Table of Contents