JUSP-NS300
DeviceNet unit
DeviceNet connectivity with positioning
functionality.
• Connects directly to the Sigma-II series drive
• Simplifies distributed control and information
management
• No programming languages are required.
• Various positioning functions including point-to-
point mode (with multi-step speed positioning avail-
able) and station number mode (indexing function)
• All parameters are set and maintained by a
PLC or PC.
• Up to 63 servos can be connected to the DeviceNet
network
• Supports polling I/O and explicit messages

System configuration

SERVOPACK
SGDH-
Ver.
CHARGE
POWER
CN3
CN1
Limit switches
contact sensors
CN2
DeviceNet unit
CJ1/CS1 series
DeviceNet master
DeviceNet
NS300
JUSP-NS300
Sigma-II
8
9
200V
X
10
4
3
8
9
series
X
DeviceNet unit
1
4
3
8
9
D
R
4
3
C
Servo Drive
N
11
M
S
N
S
Sigma-II series
Servo Motor
Cable connection
Sigma-II
JUSP-NS300
SERVOPACK
NS300
SGDH-
8
9
X
200V
Ver.
4
10
series
3
DeviceNet unit
8
9
X
1
4
3
8
9
D
4
R
3
Servo Drive
C
N
11
CHARGE
POWER
M
CN3
S
(CN11)
N
S
(CN10)
CN1
(CN6)
(CN4)
CN2
NS300
SERVOPACK
SERVOPACK
SGDH-
SGDH-
8
9
X
200V
4
10
Ver.
3
Ver.
200V
8
9
X
4
1
3
8
9
D
R
4
3
C
N
11
CHARGE
POWER
CHARGE
POWER
M
CN3
S
CN3
N
S
CN1
CN1
CN2
CN2
Computer connecting cable
DeviceNet network
External I/O or fully-closed encoder signal
NS300
NS300
SERVOPACK
SGDH-
8
8
9
9
X
X
200V
4
10
4
10
Ver.
3
3
8
8
9
9
X
X
4
1
4
1
3
3
8
8
9
D
9
D
R
R
4
4
3
3
C
C
N
N
11
11
CHARGE
POWER
M
M
S
CN3
S
N
N
S
S
CN1
Sigma-II series
CN2
Linear Motor
99

Advertisement

loading

Summary of Contents for Omron JUSP-NS300

  • Page 1: System Configuration

    (indexing function) • All parameters are set and maintained by a PLC or PC. • Up to 63 servos can be connected to the DeviceNet network • Supports polling I/O and explicit messages System configuration...
  • Page 2: Transmission Specifications

    Parameters damage, parameter setting errors, communications errors, etc. LED indicators MS: Module status NS: Network status Note: *The allocation of the output signals for brake interlock, servo ready, or positioning completion can be changed using parameter settings. Transmission specifications Item Specifications...
  • Page 3 Nomenclature Ground wire Connected to ground mark on the servo drive Rotary switch (x1, x10) For node address setting Rotary switch (DR) For transmission speed setting RS-232C connector (CN11) For setup tool LED (MS) Module status LED (NS) DeviceNet network status...
  • Page 4: Installation

    1 Connect when using an absolute encoder and when the battery is not connected to CN8. 2 Set the signal assignment with the user constants. Note: Connect the ground cable of the field bus I/F unit to the ground connector of the servo drive. Motion controllers...
  • Page 5: Ordering Information

    Connector for CN6. DeviceNet multi-branching XW4B-05C4-TF-D Connector with retaining screws Connector for CN6. DeviceNet multi-branching XW4B-05C4-T-D Connector (without retaining screws) Note: For a complete view of DeviceNet network accessories, refer to automation systems catalogue or contact your OMRON repre- sentative. Computer software Name Model...
  • Page 6 ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. Cat. No. I11E-EN-02 Motion controllers...