Omron JUSP-NS600 System Configuration

Omron JUSP-NS600 System Configuration

Indexer unit

Advertisement

Quick Links

JUSP-NS600
Indexer unit
Smart and simple positioning solution.
• No programming languages are required. Connects
directly to the Sigma-II series drive
• Allows serial network control and discrete I/O
control
• Servo axis set-up, actuation and monitoring
• 128 indexing programmed moves
• Refined methods and functions for smart control
like program tables or position and speed tables
• Up to 16 servos can be connected via serial
network
• With SigmaWin+ the system can be easily
configured
System configuration
Using serial communications
Controls 16 axes through RS-485/RS-422
SERVOPACK
SGDH-
200V
Ver.
CHARGE
POWER
CN3
CN1
Limit switches
contact sensors
CN2
Indexer unit
CJ1/CS1 series
Host controller
NS600
Sigma-II
JUSP-NS600
series
Indexer unit
Servo Drive
Sigma-II series
Servo Motor
NS600
NS600
SERVOPACK
SERVOPACK
SGDH-
SGDH-
200V
200V
Ver.
Ver.
CHARGE
POWER
CHARGE
POWER
CN3
CN3
CN1
CN1
CN2
CN2
Using digital I/O
NS600
SERVOPACK
SGDH-
200V
Ver.
CHARGE
POWER
CN3
CN1
Sigma-II
series
CN2
Linear Motor
111

Advertisement

loading

Summary of Contents for Omron JUSP-NS600

  • Page 1 • 128 indexing programmed moves • Refined methods and functions for smart control like program tables or position and speed tables • Up to 16 servos can be connected via serial network • With SigmaWin+ the system can be easily...
  • Page 2: Specifications

    START/HOME (start signal / zero-point return execution) PGMRES/JOGP (program reset / motor forward rotation) SEL0/JOGN (program starting step designation / motor reverse rotation) SEL1 to SEL4 / JOG0 to JOG3 (program starting table selection / JOG speed table selection) Output Servo drive...
  • Page 3 Nomenclature Ground wire Connected to ground on the servo drive LED (STS) Status indicator (green or red) RS-232C connector (CN7) For setup tool Rotary switch For axis address setting I/O signal connector (CN4) Serial communications connector (CN6) Dimensions JUSP-NS600 - indexer unit Units: mm Approx.
  • Page 4: Installation

    1: The L3 terminal is for specifications requiring a three-phase power supply. 5: The signal on the first line is in mode 0, and the signal on the second line is in mode 1. 2: The control power supply for 400 V-class servo drive is 24 VDC.
  • Page 5: Ordering Information

    Note: Refer to the servo systems section for more information. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice.