Omron H8GN - V1.02 Manual page 6

Preset counter/timer
Table of Contents

Advertisement

Nomenclature
No. 1 Display
Displays the present value or parameter type.
When totalizing count is displayed, the
leftmost 4 digits of the 8-digit totalizing count
will be displayed. (Zeros suppressed)
Operation display 1
Displays the time unit when the
timer function has been selected.
Example
5 h 30 min
123.4 s
Flashes while timer is on 0.0 min,
0 h 00 min, 0.0 h, or 0 h.
Level Key
Press this key to select the setup
level. The setup level is selected in
order "operation level"
"adjustment level", "initial setting
level"
"communications setting
level".
C-64
Preset Counter/Timer
Mode Key
Press this key to select
parameters within each
level.
H8GN
Operation display 2
Indicator
CMW
Lit when communications writing is enabled.
RST
Lit during reset using reset input or Reset Key.
OUT
Lit when control output is ON.
TOTAL
Lit when totalizing count value is displayed.
Down Key
Each press of this key decreases
values displayed on the No. 2
display. Hold down this key
continuously to decrease values
quickly. Also returns setting
items.
Meaning
No. 2 Display
Displays set value or
set value of the
parameter.
Displays the
rightmost 4 digits of
the count value (8
digits) when the
H8GN is used as a
totalizing counter.
(Zeros suppressed)
Up/Reset Key
Each press of this key
increases values
displayed on the No. 2
display. Hold down this
key continuously to
increase values quickly.
Also advances setting
items.
Reset Function
To reset the present
value, press this key
while the present value
is displayed.
If this key is pressed
while the totalizing
count value is
displayed, the totalizing
count value and the
present value will be
reset.