Omron G3RV Manual page 11

Slim relay g3rv series
Table of Contents

Advertisement

■ Wiring
Use wires of the applicable sizes specified above. The length of the exposed conductor should be 7 mm for a G3RV-SL700 series, 12 mm for a
G3RV-SL500 series.
G3RV-SL700
G3RV-SL500
Fig. 1 Exposed Conductor Length
Wiring Procedure for G3RV-SL500 series
● Wiring
Insert the exposed conductor into the connection hole.
No other tools are required.
Note: In case of wiring stranded wires without ferrules screwdriver
should be inserted before inserting the wire.
Screwdriver should be removed after fully insertion of the wire.
7 mm
12 mm
Screwdriver hole
Wire connection hole
Wire
● Removing
Insert the specified screwdriver into the release hole.
Removing wire.
Removing screwdriver.
Slim Relay
G3RV
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

G3rv-sl700G3rv-sl500-aG3rv-sl500-alG3rv-sl500-d

Table of Contents