Omron FQ - SHORT Manual page 71

Vision sensor
Table of Contents

Advertisement

Settings
[In/Out] − [I/O setting] − [Input] − [Input mode]
The scene numbers that can be used depend on the input mode.
[Standard mode] (default): Scene 0 to 31
[Expanded mode]: Scene 0 to 15
Sample Ladder Program
This sample program is used to change the scene when the input mode is set to Expanded Mode. The scene
changes to scene 1 when W0.00 turns ON.
W0.00
Scene change
bit
W0.00
Scene change
bit
T0000
OUT1
BUSY
IN5
T0001
BUSY
I/O Signal Allocations
Signal
Output signals
OUT1 (BUSY signal)
Input signals
IN0
IN1
IN2
IN3
IN4
IN5
Note
The BUSY signal will be ON while the scene it being changed.
FQ Short Manual
When the scene change bit (W0.00) turns ON,
MOV
the scene number is input to IN0 to IN3 and
#1100
IN4 is turned ON.
Q:1
TMHH
0000
If the BUSY signal is OFF 5 ms after the
#5
scene number is input, the trigger to change
the scene (IN5) is turned ON.
SET
IN5
RSET
W0.00
TMHH
0001
#2
The trigger to change the scene (IN5) is kept
ON for 2 ms and then turned OFF.
RSET
IN5
When the BUSY signal turns OFF to indicate
SET
that the scene has been changed, processing
after changing the scene is performed (W0.01
W0.01
turned ON).
Address
CIO 0.01
CIO 1.08
CIO 1.09
CIO 1.10
CIO 1.11
CIO 1.12
CIO 1.15
Controlling the Sensor from an External Device
69

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fq

Table of Contents