Output OR0 to OR31 signals are held until the next judgement output.
ON
TRIG signal
OFF
ON
BUSY signal
OFF
Example:
OR0 signal
OR1 signal
*1: The timing for updating the OR signal is when the measurement results are finalized, regardless of the output settings of the BUSY signal
(BUSY output conditions).
Settings
[In/Out] − [I/O setting] − [Output]
1
Press [OUT0].
2
Press [OR2 (Item 2 judgement)].
OR2 output signal was assigned to OUT0.
3
Assign the others in the following manner.
OUT1: OR5
OUT2: OR14
FQ Short Manual
ON for 1 ms min.
ON while measurements are
being processed (depends
on BUSY output conditions)
Individual
judgement
Turned ON when individual
judgement is NG.
(Output polarity: ON for NG)
Turned ON when individual
judgement is NG.
(Output polarity: ON for NG)