Omron FQ - SHORT Manual page 18

Vision sensor
Table of Contents

Advertisement

I/O Signal Circuit Diagrams
NPN
Important
Preventing Chattering
• The Sensor is equipped with an anti-chattering function, but if the chattering is 100 µs or longer, a faulty input may
occur. (Input signals of 99 µs or shorter are ignored. Signals of 100 µs or longer are treated as input signals.)
• Use no-contact output devices (e.g., SSR or PLC transistor output) for the input signals. If contacts (e.g., relay) are
used, chattering may cause the trigger to be input again during execution of a measurement.
Power Supply Specifications When a Switching Regulator Is Connected
Use a power supply that meets the following specifications. (The power supply is sold separately.)
Item
Power supply voltage
Output current
Recommended Power Supply
External power supply terminal screws
Important
Supply power from a DC power supply for which measures have been applied to prevent high voltages (e.g., a safety
extra low voltage circuit).
If UL certification is required for the overall system, use a UL Class II DC power supply.
Attaching the LED Warning Label
Attach the enclosed LED warning label to the cable or other location. The LED warning label must be attached
to a location that is readily visible from the Sensor.
Attachment Example
16
Wiring
Brown Power supply (24 VDC)
Load
Black
OUT0 (OR)
Orange
OUT1 (BUSY)
Light blue
OUT2 (ERROR)
24 VDC
Blue
GND (0V)
Pink
TRIG
IN0
Gray
IN1
Green
IN2
Red
IN3
White
Purple
IN4
IN5
Yellow
Warning Label
Warning Label
PNP
Description
24 VDC (21.6 to 26.4 V)
3.75 A min.
S8VS-09024@ (24 VDC, 3.75 A)
M4 (tightening torque: 1.2 N·m)
Max.60mW 400msec
400-700nm
JIS C 6802:2005
Brown Power supply (24 VDC)
Pink
TRIG
Gray
IN0
Green
IN1
Red
IN2
White
IN3
Purple
IN4
Yellow
IN5
24 VDC
Light blue
OUT2 (ERROR)
Orange
OUT1 (BUSY)
Black
OUT0 (OR)
Load
Blue
GND (0V)
LED RADIATION
DO NOT STARE
INTO BEAM
Max.60mW 400msec
400-700nm
CLASS 2 LED PRODUCT
IEC 60825-1:1993 +A1:1997
+A2:2001
FQ Short Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fq

Table of Contents