Application (measurement)
Defect
Characters
Angle
Quantities
1 2 3 4
Shapes (correlation values)
Classification
Brightness
Note: These processing items are most effective when set immediately after image input processing item (Camera image input or Camera switching). Depending on
conditions, however, high-speed processing may not be possible.
Measurement Support
Functions
• Calculation
• Get unit data
• Set unit data
• Wait
• Elapsed time
• Trend monitor
Branch Control Functions
• Conditional branch
• DI branch
• End
F210
Processing item
Surface Defect
Density Defect
Surface Defect (Variable Box)
EC Defect
Fine Matching
QUEST Character Verification
Lot Number OCR 1
OCR for 1 Character
Binary Defect
Binary Gravity and Angle
Rotation Positioning
Rotation Search
Circular Angle
Labeling
Label Data
Edge Pitch
EC Circle Count
Pattern
Flexible Search
Fine Matching
Classification
Classification #
Density Data
Results Output Functions
• Memory card data out-
put
• DO data output
• Host link data output
• Normal data output
• DO judgement output
Results Display Functions
• String display
• Measurement display
• Judgement display
• Item display
• Time display
• Figure display
Controller
F210
F250
YES
YES
Only one region can be set per Unit. Menu levels are sim-
ple and easy to understand.
NO
YES
Up to eight regions can be set per Unit, with results dis-
played in a list. The number of Units can be reduced.
YES
YES
Used for inspecting measurement items with varying posi-
tions and sizes.
YES
YES
Uses edge codes for defect inspection so that processing
is not affected by deformation or dirt.
YES
YES
Accurately detects differences with models.
YES
YES
Used to verify multiple characters.
YES
YES
Handles lot numbers that are changed daily, weekly,
monthly, or annually.
YES
YES
---
YES
YES
Up to eight regions can be set per Unit, with results dis-
played in a list. The number of Units can be reduced.
YES
YES
Only one region can be set per Unit. Menu levels are sim-
ple and easy to understand.
NO
YES
High-speed processing is possible. (See note.)
YES
YES
Used when the measurement item rotates.
YES
YES
Used only for circular measurement items.
Enables higher-speed processing compared to Rotation
Search. (See note.)
YES
YES
Counts up to 2,500.
YES
YES
Gets label measurement values from other Units.
YES
YES
Gets the number, pitch, and width.
YES
YES
Finds circles using "round" shape information so that pro-
cessing is not affected even if the circles are deformed or
dirty.
NO
YES
Up to 64 regions can be registered per Unit, enabling high-
speed processing. (See note.)
YES
YES
Searching can be performed even if there is variation in
model images.
YES
YES
Accurately detects differences with models.
NO
YES
Enables higher-speed processing compared to Classifica-
tion #. (See note.)
YES
YES
---
YES
YES
---
• Line results display
• Box display
• Circle display
• Cursor display
• Newest NG image display
Remarks