Using the Support Software Port
E5GN
Side View of the E5GN
Note Hold the connector when inserting or disconnecting the Cable.
3. Install the driver.
Install the driver to enable the Cable to be used with the personal comput-
er.
• Installation
When the Cable is connected with the personal computer, the OS detects
the product as a new device. At this time, install the driver using the instal-
lation wizard. For details on installation methods, refer to the user's man-
ual for the E58-CIFQ1 USB-Serial Conversion Cable.
4. Setting Setup Tool Communications Conditions
Set the communications port (COM port) number to be used for the CX-
Thermo Setup Tool to the COM port number assigned to the USB-Serial
Conversion Cable.
Refer to the E58-CIFQ1 USB-Serial Conversion Cable Instruction Manual
and Setup Manual for details on how to check the COM port assigned to
the USB-Serial Conversion Cable.
The communications conditions for Setup Tool COM ports are fixed as
shown in the table below. Set the communications conditions for the CX-
Thermo Setup Tool according to the following table.
Parameter
Communications Unit No.
Communications baud rate
Communications data length
Communications stop bits
Communications parity
Setup Tool port
Set value
01
38.4 (kbps)
7 (bits)
2 (bits)
Even
Section 2-2