Omron E3X-NL Datasheet page 9

Optical fiber glossy object sensor
Table of Contents

Advertisement

Remote teaching function
In remote teaching, the remote RUN/TEACH input signal is
used for teaching instead of the mode selector and the remote
teaching input signal is used instead of the teaching button.
Pro-
ce-
dure
1
Set the mode selector to
The following signal conditions must be given as remote
teaching input conditions.
2
A If there is a teaching error after performing remote two-
point teaching with E3X-NL, try performing remote two-
point teaching again. If the remote RUN/TEACH input is
set from L to H after the teaching error, the thresholds set
with E3X-NL will not be refreshed.
B When remote teaching is not performed, cut the pink and
purple wires at the root of the cable or connect them to the
+ side (+V) of the power supply, and cut the orange wire
at the root of the cable or connect it to GND (0 V).
C About 1 s after remote teaching is over, the Sensor is
made ready to detect an object.
E3X-NL
Operation
.
RUN
Brown + V
Black Control output
Orange Answer-back output
Purple Remote teaching input
Pink Remote
RUN/TEACH input
Blue 0V
(Remote 2-point teaching)
T2 * 1.0 to 1.3s
T1 *
H
Remote
RUN/TEACH input
L
H
Remote
teaching input
L
H
Answer-back output
L
(If teaching is OK.)
H
Answer-back output
L
(If teaching is NG.)
* Note: T1 must be 20 ms minimum and T2 must be 500 ms minimum at the time of remote
teaching.
(Remote 1-point teaching)
T2 * 1.0 to 1.3s
T1 *
H
Remote
RUN/TEACH input
L
H
Remote
teaching input
L
H
Answer-back output
L
Miscellaneous
EEPROM Write Error
If a write error occurs (buzzer beeps, red and green teaching
indicators flicker at the same time, operation and stability indi-
cators flicker) due to power-off, static electricity or other noise
in the teaching mode (until the initial operation level compen-
sation completion of teaching without object), perform teach-
ing again with the unit button.
Note: If a memory error occurs, the red and green teaching indicators flicker at
the same time and the stability indicator flickers, unlike the teaching error.
T1
T2
1.0 to 1.3s
T1
0.5s
0.5s
0.5s
0.5s 0.5s 0.5s
0.1s
0.1s
T1
0.5s
A-205

Advertisement

Table of Contents
loading

Table of Contents