Summary of Contents for Omron E3X-DACLRX1P-M3J 0.3M
Page 1
At the end of this document you will find links to products related to this catalog. You can go directly to our shop by clicking HERE. HERE...
Page 2
(good and bad sample) *1. NPN models are available. Contact your Omron representative. *2. Models with 2 m PVC cable or M12 pigtail connector are available. Contact your Omron representative. Content list All products can be ordered separately under the following order codes: E3X-CLRX1P-M3J 0.3M...
E3X-DACLR Ratings and Specifications Amplifier Units Item Type Single colour 1 to 4 colour Light source (wavelength) White LED (420 to 700 nm) C Mode: RGB ratio determination (or I Mode: Light intensity determination for red, green, or blue; Sensing method Black Mode: Determination of total light intensity for red, green, and blue) *1 Number of registered (2-color simultaneous determination ...
Page 4
E3X-DACLR *3. Mutual interference prevention cannot be used in super-high-speed mode, Contact input Non-contact input and light intensity determination (I Mode) must be used. The response time (relay or switch) (transistor) will be 150 s if an AND or OR is set for the control outputs. ON: Shorted to 0 V ON: 1.5 V max.
E3X-DACLR I/O Circuit Diagrams NPN Output (available on request) Operation Operation Model Timing charts selector Output circuit mode switch Match Mismatch Operation Operation I mode indicator (orange) ON for LIGHT ON Display indicator (orange) Brown indicator Output (Orange) match (L-ON) transistor Load Black...
E3X-DACLR Nomenclature Amplifier Units Single colour 1 to 4 colour Sub-display (green) Operation Keys Main Display (red) Operation Keys Main Display (red) Sub-display (green) Function setting operations Threshold, function settings, etc. Function setting operations Incident level, function, etc. Incident level, function, etc. Threshold, function settings, etc.
E3X-DACLR Precautions for Correct Use Do not use the product in atmospheres or environments that Adding and Removing Amplifier Units exceed product ratings. Adding Amplifier Units Amplifier Unit 1. Mount the Amplifier Units one at a time onto the DIN track. ●...
Page 8
E3X-DACLR Fiber Connection EEPROM Writing Error The E3X Amplifier Unit has a lock button for easy connection If the data is not written to the EEPROM correctly due to a of the Fiber Unit. Connect or disconnect the fibers using the power failure or static-electric noise, initialize the settings with following procedures: the keys on the Amplifier Unit.
Page 9
E3X-DACLR (Unit: mm) Dimensions Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified. Amplifier Units Area of digital indication Pre-wired Amplifier Unit E3X-DACLRX4P Round ( ): I Mode indicator Oblong ( ): Operation indicator for channel 2 15.6 35.25 Operation indicator...
Page 10
E3X-DACLR Amplifier Unit with Connectors Area of digital indication E3X-DACLRX1P Round ( ): I Mode indicator Oblong ( ): Operation indicator for channel 2 15.6 35.25 Operation indicator Main display Sub-display DIN track mounting 141.1 141.1 180° 101.45 101.45 A dia. 12.95 5.65 Hole for optical communications...
Page 13
Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS.
Page 14
Below is a list of articles with direct links to our shop Electric Automation Network where you can see: • Quote per purchase volume in real time. • Online documentation and datasheets of all products. • Estimated delivery time enquiry in real time. •...
Need help?
Do you have a question about the E3X-DACLRX1P-M3J 0.3M and is the answer not in the manual?